General information
Cooling and mounting type | Wall mounting |
Certifications | |
CE | Yes |
UKCA | Yes |
UL |
cULus E225616 Power conversion equipment |
Mains connection
Operating conditions
Ambient conditions
Temperature | |
Operation | |
Nominal | 5 to 40°C |
Maximum | 55°C |
Storage | -25 to 55°C |
Transport | -25 to 70°C |
Relative humidity | |
Operation | 5 to 85% |
Storage | 5 to 95% |
Transport | Max. 95% at 40°C |
Mechanical properties
Vibration and shock | 3M1 per IEC 60721-3-3 |
Dimensions | |
Width | 45 mm |
Height | 263.8 mm |
Depth | 70 mm |
Weight | 0.85 kg |
Malzeme numarası:
8B0F0160H000.000-1Açıklama:
- Wide mains input voltage range
- Optimized for ACOPOSmulti 8B0P power supply modules and ACOPOS P3
- Compliance with limit values per CISPR11, group 2, class A
In order to conform to the EMC limit values, all 8BVI inverter modules in the drive system connected to the 8B0F line filter must be operated at the nominal switching frequency (5 kHz). The total length of all motor cables on each drive system (and for each 8B0F line filter) is not permitted to exceed 250 m. The cable length between the 8B0F line filter and the 8B0P power supply module is not permitted to exceed 5 m. The maximum permissible motor cable length per motor connection must also be taken into account (see 8BVI inverter modules).
Dökümantasyon | Sürüm (Tarih) | İndirme |
---|---|---|
Datasheet 8B0F0160H000.000-1 | PDF / 1,007 KB |
M-CAD (Mechan. Şablonlar) | Sürüm (Tarih) | İndirme |
---|---|---|
3D file DXF/STEP 8B0F0160H000.000-1 | ZIP / 137 KB |
Sertifikalar | Sürüm (Tarih) | İndirme |
---|---|---|
EU Declaration Servos ACOPOSmulti | PDF / 219 KB | |
UK Declaration Servos ACOPOSmulti | PDF / 109 KB |