Short description
Communication module | 1x PROFIBUS DP V0/V1 master |
General information
B&R ID code | 0xA716 |
Status indicators | Module status, data transfer |
Diagnostics | |
Module status | Yes, using LED status indicator and software |
Network status | Yes, using LED status indicator and software |
Data transfer | Yes, using LED status indicator |
Power consumption | 1.8 W |
Additional power dissipation caused by actuators (resistive) [W] | - |
Certifications | |
CE | Yes |
UKCA | Yes |
ATEX |
Zone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user's manual) FTZÚ 09 ATEX 0083X |
UL |
cULus E115267 Industrial control equipment |
HazLoc |
cCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5 |
DNV |
Temperature: B (0 to 55°C) Humidity: B (up to 100%) Vibration: B (4 g) EMC: B (bridge and open deck) |
CCS | Yes |
LR | ENV1 |
KR | Yes |
ABS | Yes |
BV |
EC33B Temperature: 5 - 55°C Vibration: 4 g EMC: Bridge and open deck |
KC | Yes |
Interfaces
Interface IF1 | |
Fieldbus | PROFIBUS DP V0/V1 master |
Variant | 9-pin female DSUB connector |
Max. distance | 1200 m |
Transfer rate | Max. 12 Mbit/s |
Controller | netX100 |
Memory | 8 MB SDRAM |
Cyclic data | |
Input data | Max. 3.5 kB |
Output data | Max. 3.5 kB |
Electrical properties
Electrical isolation | PLC isolated from PROFIBUS (IF1) |
Operating conditions
Mounting orientation | |
Horizontal | Yes |
Vertical | Yes |
Installation elevation above sea level | |
0 to 2000 m | No limitation |
>2000 m | Reduction of ambient temperature by 0.5°C per 100 m |
Degree of protection per EN 60529 | IP20 |
Ambient conditions
Temperature | |
Operation | |
Horizontal mounting orientation | -25 to 60°C |
Vertical mounting orientation | -25 to 50°C |
Derating | - |
Storage | -40 to 85°C |
Transport | -40 to 85°C |
Relative humidity | |
Operation | 5 to 95%, non-condensing |
Storage | 5 to 95%, non-condensing |
Transport | 5 to 95%, non-condensing |
Mechanical properties
Slot | In the X20 PLC and expandable bus controller X20BC1083 |
Número do material:
X20IF1061-1Descrição:
- PROFIBUS DP V1 master
The interface module is equipped with a PROFIBUS DP V1 interface. This allows third-party components to be integrated in the B&R system and makes it possible to quickly and easily transfer data in both directions.
The interface module can be operated in X20 CPUs or in the expandable POWERLINK bus controller X20BC1083.
Acessórios opcionais
Infrastructure components
0G1000.00-090 | Bus connector, RS485, for PROFIBUS networks |
Atualizações de HW Automation Studio | Version (Data) | Download |
---|---|---|
V3.0 HW Upgrade (X20IF1061-1) | EXE / 679 KB | |
V3.0 HW Upgrade (X20IF1061-1) | EXE / 1 MB | |
V4.0 HW Upgrade (X20IF1061-1) | EXE / 2 MB |
Documentação | Version (Data) | Download |
---|---|---|
Data sheet X20(c)IF1061-1 | PDF / 1 MB | |
Installation- / EMC-Guide | PDF / 20 MB | |
X20 Package leaflet ATEX/CSA | PDF / 2 MB | |
X20 System User´s Manual | PDF / 7 MB |
E-CAD (Modelos Electro ou EPLAN) | Version (Data) | Download |
---|---|---|
X20 EPLAN P8 from V2.4 | EXE / 160 MB |
M-CAD (Mechan. Modelos) | Version (Data) | Download |
---|---|---|
3D File DXF/STEP X20 Interface module X20(c)IF106x(-1) | ZIP / 1 MB |