Additional information
8LWA synchronous motors
8LWA - General motor data
8LWA - Order key
8LWA
General information | 8LWA |
---|---|
CE certification | Yes |
C-UR-US listed | Yes |
UL file number | PRHZ2.E235396 |
Electrical characteristics | 8LWA |
---|---|
DC bus voltage on the ACOPOS P3 | 325 VDCPermissible DC bus voltage on the ACOPOS P3, single-phase: 325 VDC |
Conventional connection type (power connection / encoder connection) | ytec circular connector |
Connection type - Single-cable solution (hybrid) | htec circular connector |
Support | 8LWA |
---|---|
Automation Studio | V4.4.6 and higher |
Motion system | |
mapp Motion | Version 5.08.0 and higher |
ACP10 | Version 5.04.0 and higher |
Thermal properties | 8LWA |
---|---|
Insulation class per EN 60034-1 | F |
Methods of cooling per EN 60034-6 (IC code) | Self-cooling, free circulation surface cooling (IC4A0A0) |
Thermal motor protection per EN 60034-11 | Size 1: No Maximum winding temperature 145°C (limited to 130°C by the thermal motor protection in the ACOPOS P3 drive system) |
Mechanical properties | 8LWA |
---|---|
Roller bearing, dynamic load rating and nominal service life | Based on DIN ISO 281 |
Shaft end per DIN 748 | Form E |
Oil seal per DIN 3760 | Form A |
Key and keyway per DIN 6885-1 | Form A keys, form N1 keyway |
Shaft balancing per ISO 1940/1, G6.3 | Shaft and fitment key convention |
Mounting flange | IEC 72-1 |
Radial runout, concentricity and axial runout of mounting flange per DIN 42955 | Tolerance R |
Coating Color | Water-based coating RAL 9005 flat |
Operating conditions | 8LWA |
---|---|
Rating class, operating mode per EN 60034-1 | S1 - Continuous operation |
Ambient temperature during operation | -15°C to +40°C |
Maximum ambient temperature during operation | +50°CContinuous operation at an ambient temperature of +40°C to max. +50°C is possible, but this results in premature aging. |
Relative humidity during operation | 5 to 95%, non-condensing |
Reduction of the nominal current and stall current at temperatures above 40°C | 5% per 5°C |
Reduction of rated and stall current at installation elevations Starting at 1000 m above sea level | 5% per 1000 m |
Maximum installation elevation | 4000 mRequirements that go beyond this must be arranged with B&R. |
Max. flange temperature | 65°C |
Degree of protection per EN 60034-5 (IP code) The degrees of protection are only achieved if the power and signal connections are fully installed. - Without oil seal - With oil seal |
IP64 IP65 |
Type of construction and mounting arrangement per EN 60034-7 (IM code) | Horizontal (IM3001) Vertical, motor attached to the machine (IM 3011)With the IM 3011 type of construction and mounting arrangement (vertical, motor attached to the machine), there is a risk of production fluids or oils penetrating the motor on the flange side. Motors or motor-gearbox combinations that should be used with this mounting arrangement must therefore have at least IP65 protection on the flange side. Vertical, motor stands on the machine (IM3031) |
Storage and transport conditions | 8LWA |
---|---|
Storage temperature | -20 to +60°C |
Relative humidity during storage | Max. 90%, non-condensing |
Transport temperature | -20 to +60°C |
Relative humidity during transport | Max. 90%, non-condensing |