General information | Cooling type A |
---|---|
C-UR-US listed | Yes |
UL file number | E61960 |
Electrical properties | |
---|---|
Mains input voltage on servo drive | 3x 400 VAC ... 3x 480 VAC ±10% |
Connection type Motor connection Encoder connection | speedtec circular connector from Intercontec Size 1 Size 1 |
Thermal properties | |
---|---|
Insulation class per EN 60034-1 | F |
Methods of cooling per EN 60034-6 (IC code) | Self-cooling, free circulation surface cooling (IC4A0A0) |
Thermal motor protection per EN 60034-11 | Maximum winding temperature 140°C (limited by the thermal motor protection in the B&R drive system to 110°C with EnDat feedback and 130°C with resolver feedback) KTY83-110 |
Mechanical properties | |
---|---|
Vibration severity per EN 60034-14 | Vibration severity stage A 1) |
Roller bearing, dynamic load rating and nominal service life | Based on DIN ISO 281 |
Shaft end per DIN 748 | Form E |
Oil seal per DIN 3760 | Form A |
Key and keyway per DIN 6885-1 | Form A keys, form N1 keyway |
Shaft balancing per ISO 1940/1, G6.3 | Shaft and fitment key convention |
Mounting flange | IEC 72-1 |
Radial runout, concentricity and axial runout of mounting flange per DIN 42955 | Tolerance N |
Coating Description Color | Polyester powder coating Mansfield 053-2006 polyester Similar to RAL 9005 flat |
Operating conditions | |
---|---|
Rating class, operating mode per EN 60034-1 | S1 - Continuous operation 2) |
Ambient temperature during operation | 5°C to 40°C 3) |
Relative humidity during operation | 5 to 95%, non-condensing |
Maximum ambient temperature during operation | 40°C 3) |
Reduction of the nominal current and stall current at temperatures above 40°C | 5% per 5°C |
Maximum installation elevation | 1000 m above sea level 4) |
Reduction of rated and stall current at installation elevations Starting at 1000 m above sea level | 5% per 1000 m |
EN 60034-5 protection (IP code) With oil seal option | IP54 IP65 |
Type of construction and mounting arrangement per EN 60034-7 (IM code) | Horizontal (IM3001) Vertical, motor hangs on the machine (IM3011)5) Vertical, motor stands on the machine (IM3031) |
Storage and transport conditions | |
---|---|
Storage temperature | -20 to 60°C |
Relative humidity during storage | Max. 90%, non-condensing |
Transport temperature | -20 to 60°C |
Relative humidity during transport | Max. 90%, non-condensing |
1) | Valid for all motors with a shaft height greater than 56 mm. |
2) | The boundary conditions in section Power dissipation must be taken into account. |
3) | Continuous operation of the servo motors at an ambient temperature of 40°C to max. 45°C is possible, but this results in premature aging. |
4) | Requirements that go beyond this must be arranged with B&R. |
5) | With the IM3011 type of construction and installation (vertical, motor hangs on the machine) there is a risk that production fluids or oils will penetrate the motor on the flange side. Motors or motor-gearbox combinations that should be used in this type of installation must therefore have at least IP65 protection on the flange side. |