Short description
Interfaces | 1x Ethernet, 1x USB, 3x CAN bus, 1x POWERLINK |
System module | Controller |
General information
Safety characteristics
Note | See section "Safety characteristics" in data sheet. |
Functionality
Limit values for SafeDESIGNER application
Input power supply
Controller
Interfaces
Multi-function inputs
Multifunction digital inputs (MF-DI) | |
Quantity | 8 |
Functions |
Type B, sink circuit, configurable software input filter, counter function Up to 50 kHz counting frequency (1x AB or 1x AA or 2x A) Sink/Source circuit - Configurable per channel, configurable software input filter, counter function up to 50 kHz counter frequency (AB, ABR, DF, edge counter), edge detection with timestamp (for period duration, gate measurement, differential time measurement) |
Multifunction analog inputs (MF-AI) | |
Quantity | 16 |
Functions |
Type B, sink circuit, configurable software input filter Type B, measurement range 0 to 10 V / 0 to 32 V / 0 to 20 mA Digital inputs, sink/source circuit configurable per channel, configurable software input filter, fixed or ratiometrically configurable switching threshold, open-circuit and short-circuit detection. Digital inputs, configurable software input filter, open-circuit and short-circuit detection Analog inputs, measurement range 0 to 10 V / 0 to 32 V / 0 to 20 mA / 4 to 20 mA / 1 to 50 kΩ / temperature inputs (Pt1000 characteristic curve), configurable analog filter, configurable ramp limit, configurable threshold values, integrated input protection |
Multi-function outputs
Multifunction digital outputs (MF-DO) | |
Quantity | 8 |
Functions |
Type C, 4 A nominal current, source circuit, integrated output protection per channel, central cutoff via relay, error state 4 A nominal current, source circuit, integrated output protection per channel, configurable overload monitoring per channel, central cutoff via relay, parallel connection, current measurement, error state with configurable error filter Digital inputs, sink/source circuit configurable per channel, configurable software input filter |
Multifunction PWM outputs (MF-PWM) | |
Quantity |
PWM 4 A: 11 PWM 6 A: 5 |
Functions |
Type C, 4 A nominal current (PWM 4 A), 6 A nominal current (PWM 6 A), source circuit, integrated output protection per channel, central cutoff via relay, error state Safe digital outputs, 4 A nominal current (PWM 4 A), 6 A nominal current (PWM 6 A), sink/source circuit - Configurable per channel, integrated output protection per channel, configurable overload monitoring per channel, central cutoff via relay, parallel connection, current measurement, error state with configurable error filter 4 A nominal current (PWM 4 A), 6 A nominal current (PWM 6 A), PWM frequency 15 Hz to 4 kHz, sink/source circuit - Configurable per channel, integrated output protection per channel, configurable overload monitoring per channel, central cutoff via relay, parallel connection, current measurement (asynchronous or synchronous to PWM period), configurable load current distribution of PWM outputs, dither. 4 A nominal current (PWM 4 A), 6 A nominal current (PWM 6 A), PWM frequency 15 Hz to 8 kHz (at load), integrated output protection per channel, configurable overload monitoring per channel, central cutoff via relay, parallel connection, current measurement (asynchronous or synchronous to PWM period), configurable load current distribution of PWM outputs, dither. Digital inputs, sink/source circuit configurable per channel, configurable software input filter |
Digital inputs
Safe digital inputs
Quantity | 8 to 24, depends on the use of multifunction inputs |
Variant | Type B |
Nominal voltage | 12 / 24 VDC |
Input filter | |
Hardware |
MF-DI: 4 μs if switching threshold = 50% supply voltage MF-AI: 300 μs if switching threshold = 50% supply voltage |
Software | Default T_on = 256 ms / T_off = 0 ms, configurable between 0 and 1024 ms |
Input circuit | Sink |
Input voltage | 9 to 32 VDC |
Input current at 24 VDC |
MF-DI: Typ. 1.4 / 2.8 / 3.7 mA, configurable MF-AI: Typ. 1.2 / 2.5 / 3.6 mA, configurable |
Input resistance |
MF-DI: Typ. 6.4 / 8.6 / 17.8 kΩ, configurable MF-AI: Typ. 6.5 / 9 / 18 kΩ, configurable |
Error detection time | Max. 8 hours |
Switching threshold | |
Low |
MF-DI: <2.5% of supply voltage for single-channel use MF-DI: <30% of supply voltage for dual-channel use MF-AI: 50% of supply voltage |
High |
MF-DI: >60% of supply voltage MF-AI: 50% of supply voltage |
Safe digital counter inputs
Quantity | 1xAB, 1xAA or 2xA |
Variant | Type B |
Nominal voltage | 12 / 24 VDC |
Input filter | |
Hardware | MF-DI: 4 μs if switching threshold = 50% supply voltage |
Software | 10 to 100 ms, configurable |
Input frequency | MF-DI: Max. 50 kHz |
Input circuit | Sink |
Input voltage | 9 to 32 VDC |
Input current at 24 VDC | Typ. 1.4 / 2.8 / 3.7 mA, configurable |
Input resistance |
MF-DI: Typ. 6.4 / 8.6 / 17.8 kΩ, configurable MF-AI: Typ. 6.5 / 9 / 18 kΩ, configurable |
Switching threshold | |
Low | <30% of supply voltage |
High | >60% of supply voltage |
Analog inputs
Safe analog inputs
Sensor power supply
Digital outputs
Safe digital outputs
PWM output
Electrical properties
Operating conditions
Ambient conditions
Temperature | |
Operation | |
Horizontal mounting orientation | -40 to 85°C housing surface |
Vertical mounting orientation | -40 to 85°C housing surface |
Derating | See section "Derating". |
Storage | -40 to 85°C |
Transport | -40 to 85°C |
Relative humidity | |
Operation | 5 to 100%, condensing |
Storage | 5 to 95%, non-condensing |
Transport | 5 to 95%, non-condensing |
Brief overview
Content of delivery | 2x protective covers for unused female M12 connectors |
![](/fileadmin/X90CP174.48-S1_r-a46c0a48.jpg)
Materiaalnummer:
X90CP174.48-S1Omschrijving:
- Agricultural and forestry machines
- Construction equipment
- Municipal utility vehicles
- Stationary outdoor applications
- Powerful ARM CPU with 650 MHz
- Multifunction I/O channels
- Ethernet, POWERLINK, 3x CAN bus, USB
- Modular expansion
The heart of the X90 mobile system is a controller with a powerful ARM processor and up to 48 multifunction I/O channels. Basic features include connections for CAN, USB, Ethernet and the real-time POWERLINK bus system.
The extremely robust die-cast aluminum housing provides space for up to 4 additional expansion boards. These make it possible to add I/O channels or interfaces as well as specific functions such as condition monitoring.
The X90 mobile "Safety" variant is also equipped with a safe control system – also known as an X90 SafeLOGIC controller. All 48 multifunction I/Os included as standard can be used by both the standard variant and the X90 SafeLOGIC controller. Input and output signals can thus be read or operated by the standard variant and/or by the safe control system, depending on the wiring. The control lines required for this are linked by a logical AND in a safety-related manner, i.e. an output signal is only enabled if permitted by both the safety application and the standard application.
Optionele toebehoren
Analog inputs
X90AISG0.02-00 | X90 mobile option board, strain gauge module for 2 DMS full-bridge strain gauges, 24-bit converter resolution, 5 kHz input filter |
Analog outputs
X90AO410.04-00 | X90 mobile option board AO, 4 analog outputs, 12-bit, optional 0 to 10 V / 0 to 20 mA, optional DI, 9 to 32 VDC, sink/source, configuration using software |
X90AO410.08-00 | X90 mobile option board AO, 8 analog outputs, 12-bit, optional 0 to 10 V / 0 to 20 mA, optional DI, 9 to 32 VDC, sink/source, configuration using software |
BreakOut Box
X90AC-BB.17-00 | X90 mobile 170, breakout box for development and tests |
CMC connector
X90TB100.03-00 | X90 mobile 170, connector set for CMC header, with connector contacts and dummy plugs |
Communication modules
X90DSI00.04-00 | X90 IO-Link option board, digital signal module, 4x IO-Link master, 4 digital channels configurable as inputs or outputs, 3-wire connections |
X90IF720.04-00 | X90 mobile IF option board, 3x CAN, 1x RS232 configuration using software |
X90IF730.04-00 | X90 mobile IF option board, 3x CAN, 1x RS485, configuration using software |
X90IF7L0.05-00 | X90 mobile IF option board, 3x CAN, 2x LIN (master), configuration using software |
Condition Monitoring
X90CM480.04-00 | X90 mobile condition monitoring, option board for vibration measurement and vibration analysis of condition monitoring tasks, 4 IEPE analog inputs |
Digital inputs
X90DI110.10-00 | X90 mobile option board DI, 10 digital inputs, 9 to 32 VDC, optional sink/source, optional counter input 50 kHz or AB encoder, configuration using software |
Digital outputs
X90PO210.08-00 | X90 mobile option board PWM, 8x PWM outputs, 9 to 32 VDC, max. 4 A, with current measurement (12-bit), 15 Hz to 1 kHz, optional DI, 9 to 32 VDC, sink/source, configuration using software |
X90RO440.05-00 | X90 mobile option board relay, 5 relays, normally open contact, for external actuator power supply, 9 to 32 VDC / 2 A |
Motor modules
X90SM546.02-01 | X90 stepper motor module, with current reduction function, module power supply 15 to 32 VDC, 2 motor connections,4 A continuous current, 8 A peak current, NetTime function |
Safe digital outputs
X90RO440.04-S1 | X90 mobile option board with safe relay outputs, 4 relays, normally open contacts, for external actuator power supply, 9 to 32 VDC / 2 and 4 A |
Temperature measurement
X90AT910.04-00 | X90 mobile option board AT, 4 resistance measurement inputs, Pt1000, optional DI, 9 to 32 VDC, sink/source, optional AI, 0 to 10 V / 0 to 32 V, 0 to 20 mA, optional PWM output, 9 to 32 VDC, 10 mA, 1 kHz, configuration using software |
X90AT910.08-00 | X90 mobile option board AT, 8 resistance measurement inputs, Pt1000, optional DI, 9 to 32 VDC, sink/source, optional AI, 0 to 10 V / 0 to 32 V, 0 to 20 mA, optional PWM output, 9 to 32 VDC, 10 mA, 1 kHz, configuration using software |
Wire harness
X90CA100.02-00 | X90 mobile 170, wiring harness starter set for X90CP17x, 2 m, for CMC header |
Automation Studio HW Upgrades | Versie (Datum) | Download |
---|---|---|
V4.7 HW Upgrade (X90CP174.48-S1) | EXE / 6 MB | |
V4.7 HW Upgrade (X90SL104.48-S1) | EXE / 3 MB | |
V4.9 HW Upgrade (X90CP174.48-S1) | EXE / 6 MB | |
V6.0 HW Upgrade (X90CP174.48-S1) | EXE / 6 MB |
Documentatie | Versie (Datum) | Download |
---|---|---|
Datasheet X90CP174.48-S1 | PDF / 8 MB | |
Open Source Licenses X90CPxxxx | ZIP / 1 MB | |
X90 mobile System User´s Manual | PDF / 49 MB | |
X90 pin allocation CMC connector | ZIP / 3 MB |
E-CAD (Electro of EPLAN Templates) | Versie (Datum) | Download |
---|---|---|
Makro-/Artikeldaten 4.0.2 (X90CP174.48-S1) | EXE / 12 MB | |
X90 EPLAN P8 from V2.4 | EXE / 69 MB |
M-CAD (Mechan. Templates) | Versie (Datum) | Download |
---|---|---|
3D File STEP, DXF X90CP174.xx-00 | ZIP / 12 MB |
Tools / Hulpprogramma's / Voorbeelden | Versie (Datum) | Download |
---|---|---|
Sistema library | ZIP / 336 KB |