Output voltage
|
|
DC bus voltage (UDC): 260 to 315 VDC
|
25 VDC * (UDC / 315)
|
DC bus voltage (UDC): 315 to 800 VDC
|
24 VDC ±6%
|
Protection of 24 VDC Out 1 output
|
30 A (slow-blow) electronic, automatic reset
|
Protection of 24 VDC Out 2 output
|
5 A (slow-blow) electronic, automatic reset
|
Protective measures
|
|
No-load proof
|
Yes
|
Overload-proof
|
Yes
|
Short-circuit proof
|
Yes
|
Feedback protection
|
Max. 35 VDC (also when the power is switched off)
|
Overtemperature protection
|
Yes
|
Dielectric strength to ground
|
±50 VDC
|
Output/Input isolation
|
SELV / PELV requirements
|
Variant
|
|
24 VDC, COM
|
Connector
|
Terminal connection cross section of 24 VDC Out 1 output
|
|
Flexible and fine-stranded wires
|
|
With wire end sleeve
|
0.25 to 6 mm²
|
Approbation data
|
|
UL/C-UL-US
|
22 to 10 AWG
|
CSA
|
22 to 10 AWG
|
Terminal connection cross section of 24 VDC Out 2 output
|
|
Flexible and fine-stranded wires
|
|
With wire end sleeve
|
0.25 to 2.5 mm²
|
Approbation data
|
|
UL/C-UL-US
|
22 to 12 AWG
|
CSA
|
22 to 12 AWG
|