Short description
Bus controller | POWERLINK (V1/V2) controlled node with up to 2 slots for interface modules |
General information
B&R ID code | 0x2268 |
Status indicators | Module status, bus function |
Diagnostics | |
Module status | Yes, using LED status indicator and software |
Bus function | Yes, using LED status indicator and software |
Support | |
Dynamic node allocation (DNA) | Yes |
Power consumption | |
Bus | 2 W |
Additional power dissipation caused by actuators (resistive) [W] | - |
Certifications | |
CE | Yes |
UKCA | Yes |
ATEX |
Zone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user's manual) FTZÚ 09 ATEX 0083X |
UL |
cULus E115267 Industrial control equipment |
HazLoc |
cCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5 |
DNV |
Temperature: B (0 to 55°C) Humidity: B (up to 100%) Vibration: B (4 g) EMC: B (bridge and open deck) |
CCS | Yes |
LR | ENV1 |
KR | Yes |
ABS | Yes |
BV |
EC33B Temperature: 5 - 55°C Vibration: 4 g EMC: Bridge and open deck |
KC | Yes |
Interfaces
Electrical properties
Electrical isolation | POWERLINK isolated from bus and I/O |
Operating conditions
Mounting orientation | |
Horizontal | Yes |
Vertical | Yes |
Installation elevation above sea level | |
0 to 2000 m | No limitation |
>2000 m | Reduction of ambient temperature by 0.5°C per 100 m |
Degree of protection per EN 60529 | IP20 |
Ambient conditions
Temperature | |
Operation | |
Horizontal mounting orientation | -25 to 60°C |
Vertical mounting orientation | -25 to 50°C |
Derating | - |
Storage | -40 to 85°C |
Transport | -40 to 85°C |
Relative humidity | |
Operation | 5 to 95%, non-condensing |
Storage | 5 to 95%, non-condensing |
Transport | 5 to 95%, non-condensing |
型番:
X20BC1083説明:
- POWERLINK
- I/O configuration and firmware update via the fieldbus
- Integrated hub for efficient cabling
- Up to 2 slots for interface modules
The bus controller makes it possible to connect X2X Link I/O nodes to POWERLINK. It is also possible to operate the X2X Link cycle synchronously 1:1 or synchronous to POWERLINK using a prescaler.
POWERLINK is a standard protocol for Fast Ethernet equipped with hard real-time characteristics. The POWERLINK Standardization Group (EPSG) ensures that the standard remains open and is continually developed:: www.ethernet-powerlink.org.
The bus modules expanded to the left allow connection of up to 2 interface modules in addition to the bus controller.
必須アクセサリ
System modules for bus controllers
System modules for expandable bus controllers
X20BB81 | X20 bus base, for X20 base module (BC, HB, etc.) and X20 power supply module, with one expansion slot for X20 add-on module (IF, HB, etc.), X20 end cover plates (left and right) X20AC0SL1/X20AC0SR1 included |
X20BB82 | X20 bus base, for X20 base module (BC, HB, etc.) and X20 power supply module, with 2 expansion slots for 2 X20 add-on modules (IF, HB, etc.), X20 end cover plates (left and right) X20AC0SL1/X20AC0SR1 included |
Terminal blocks
X20TB12 | X20 terminal block, 12-pin, 24 VDC keyed |
オプションで付属可
System modules for expandable bus controllers
X20IF1091-1 | X20 interface module, for expandable bus controller, 1 X2X Link master interface, electrically isolated, order 1x terminal block TB704 separately! |
X20 interface module communication
X20IF1041-1 | X20 interface module, for DTM configuration, 1 CANopen master interface, electrically isolated, order 1x terminal block TB2105 separately! |
X20IF1043-1 | X20 interface module, for DTM configuration, 1 CANopen slave interface, electrically isolated, order 1x terminal block TB2105 separately! |
X20IF1051-1 | X20 interface module, for DTM configuration, 1 DeviceNet scanner (master) interface, electrically isolated, order 1x terminal block TB2105 separately! |
X20IF1053-1 | X20 interface module, for DTM configuration, 1 DeviceNet adapter (slave) interface, electrically isolated, order 1x terminal block TB2105 separately! |
X20IF1061-1 | X20 interface module, for DTM configuration, 1 PROFIBUS DP V0/V1 master interface, electrically isolated |
X20IF1063-1 | X20 interface module, for DTM configuration, 1 PROFIBUS DP V1 slave interface, electrically isolated |
X20IF10A1-1 | X20 interface module, for DTM configuration, 1 ASi master interface, electrically isolated, order 1x terminal block TB704 separately! |
X20IF10D1-1 | X20 interface module, for DTM configuration, 1 EtherNet/IP scanner (master) interface, electrically isolated |
X20IF10D3-1 | X20 interface module, for DTM configuration, 1 EtherNet/IP adapter (slave) interface, electrically isolated |
X20IF10E1-1 | X20 interface module, for DTM configuration, 1 PROFINET IO controller (master) interface, electrically isolated |
X20IF10E3-1 | X20 interface module, for DTM configuration, 1 PROFINET IO device (slave) interface module, electrically isolated |
X20IF10G1-1 | X20 interface module for DTM configuration, 1 EtherCAT master interface, electrically isolated |
X20IF10G3-1 | X20 interface module for DTM configuration, 1 EtherCAT slave interface, electrically isolated |
Automation Studio HW アップグレード | バージョン (日付) | ダウンロード |
---|---|---|
V2.6 HW Upgrade (X20BC1083) | EXE / 2 MB | |
V3.0 HW Upgrade (X20BC1083) | EXE / 2 MB | |
V4.0 HW Upgrade (X20BC1083) | EXE / 2 MB |
E-CAD(ElectroまたはEPLANテンプレート) | バージョン (日付) | ダウンロード |
---|---|---|
X20 EPLAN P8 from V2.4 | EXE / 160 MB |
M-CAD (Mechan.Templates) | バージョン (日付) | ダウンロード |
---|---|---|
3D File STEP/DXF X20BC and X20IF Module | ZIP / 1 MB |