Short description
Interfaces | 1x Ethernet, 1x USB, 3x CAN bus |
System module | Controller |
General information
Input power supply
Controller
Interfaces
Interface IF2 | |
Type | Ethernet |
Variant | M12, D-coded |
Line length | Max. 100 m between 2 stations (segment length) |
Transfer rate | 10/100 Mbit/s |
Transfer | |
Physical layer | 10BASE-T / 100BASE-TX |
Half-duplex | Yes |
Full-duplex | Yes |
Autonegotiation | Yes |
Auto-MDI/MDIX | Yes |
Interface IF4 | |
Type | USB 1.1/2.0 |
Variant | Type A (under service access window) |
Max. output current | 500 mA |
Interface IF7 | |
Connection designation | CAN1 |
Type | CAN bus |
Variant | Connection on CMC header X1.A |
Max. distance | 1000 m |
Transfer rate | Max. 1 Mbit/s |
Terminating resistor | External 120 Ω must be provided. |
Interface IF8 | |
Connection designation | CAN2 |
Type | CAN bus |
Variant | Connection on CMC header X1.A |
Max. distance | 1000 m |
Transfer rate | Max. 1 Mbit/s |
Terminating resistor | External 120 Ω must be provided. |
Interface IF9 | |
Connection designation | CAN3 |
Type | CAN bus |
Variant | Connection on CMC header X1.A |
Max. distance | 1000 m |
Transfer rate | Max. 1 Mbit/s |
Terminating resistor | External 120 Ω must be provided. |
Multi-function inputs
Multifunction digital inputs (MF-DI) | |
Quantity | 8 |
Functions |
Sink/Source circuit - Configurable per channel, configurable software input filter, counter function up to 50 kHz counter frequency (AB, ABR, DF, edge counter), edge detection with timestamp (for period duration, gate measurement, differential time measurement) |
Multifunction analog inputs (MF-AI) | |
Quantity | 16 |
Functions |
Sink/Source circuit - Configurable per channel, configurable software input filter, fixed or ratiometrically configurable switching threshold, open-circuit and short-circuit detection. Configurable software input filter, open-circuit and short-circuit detection. Measurement range 0 to 10 V / 0 to 32 V / 0 to 20 mA / 4 to 20 mA / 1 to 50 kΩ / temperature inputs (Pt1000 characteristic curve), configurable analog filter, configurable ramp limit, configurable threshold values, integrated input protection |
Multi-function outputs
Multifunction digital outputs (MF-DO) | |
Quantity | 8 |
Functions |
4 A nominal current, source circuit, integrated output protection per channel, configurable overload monitoring per channel, central cutoff via relay, parallel connection, current measurement, error state with configurable error filter. Sink/Source circuit configurable per channel, configurable software input filter |
Multifunction PWM outputs (MF-PWM) | |
Quantity |
PWM 4 A: 11 PWM 6 A: 5 |
Functions |
4 A nominal current (PWM 4 A), 6 A nominal current (PWM 6 A), sink/source circuit, integrated output protection per channel, configurable overload monitoring per channel, central cutoff via relay, parallel connection, current measurement, error state with configurable error filter. 4 A nominal current (PWM 4 A), 6 A nominal current (PWM 6 A), PWM frequency 15 Hz to 4 kHz, sink/source circuit, integrated output protection per channel, configurable overload monitoring per channel, central cutoff via relay, parallel connection, current measurement (asynchronous or synchronous to PWM period), configurable load current distribution of PWM outputs, dither. 4 A nominal current (PWM 4 A), 6 A nominal current (PWM 6 A), PWM frequency 15 Hz to 8 kHz (at load), integrated output protection per channel, configurable overload monitoring per channel, central cutoff via relay, parallel connection, current measurement (asynchronous or synchronous to PWM period), configurable load current distribution of PWM outputs, dither. Sink/Source circuit configurable per channel, configurable software input filter |
Digital inputs
Analog inputs
Sensor power supply
Digital outputs
PWM output
Electrical properties
Operating conditions
Ambient conditions
Temperature | |
Operation | |
Horizontal mounting orientation | -40 to 85°C housing surface |
Vertical mounting orientation | -40 to 85°C housing surface |
Derating | See section "Derating". |
Storage | -40 to 85°C |
Transport | -40 to 85°C |
Relative humidity | |
Operation | 5 to 100%, condensing |
Storage | 5 to 95%, non-condensing |
Transport | 5 to 95%, non-condensing |
Brief overview
Content of delivery | 2x protective covers for unused female M12 connectors |
Référence produit:
X90CP172.48-00Description:
- Agricultural and forestry machines
- Construction equipment
- Municipal utility vehicles
- Stationary outdoor applications
- Powerful ARM CPU with 300 MHz
- Multifunction I/O channels
- Ethernet, 3x CAN bus, USB
- Modular expansion
The heart of the X90 mobile system is a controller with a powerful ARM processor and up to 48 multifunction I/O channels. Basic features include interfaces for CAN, USB and Ethernet.
The extremely robust die-cast aluminum housing provides space for up to 4 additional expansion boards. These make it possible to use additional I/O channels or interfaces as well as specific functions such as condition monitoring.
Accessoires optionnels
Analog inputs
X90AISG0.02-00 | X90 mobile option board, strain gauge module for 2 DMS full-bridge strain gauges, 24-bit converter resolution, 5 kHz input filter |
Analog outputs
X90AO410.04-00 | X90 mobile option board AO, 4 analog outputs, 12-bit, optional 0 to 10 V / 0 to 20 mA, optional DI, 9 to 32 VDC, sink/source, configuration using software |
X90AO410.08-00 | X90 mobile option board AO, 8 analog outputs, 12-bit, optional 0 to 10 V / 0 to 20 mA, optional DI, 9 to 32 VDC, sink/source, configuration using software |
BreakOut Box
X90AC-BB.17-00 | X90 mobile 170, boîte de dérivation pour le développement et les tests |
CMC connector
X90TB100.03-00 | X90 mobile 170, jeu de connecteurs pour l'en-tête CMC, avec contacts de connexion et fiches fictives |
Communication modules
X90DSI00.04-00 | X90 IO-Link option board, digital signal module, 4x IO-Link master, 4 digital channels configurable as inputs or outputs, 3-wire connections |
X90IF720.04-00 | X90 mobile IF option board, 3x CAN, 1x RS232 configuration using software |
X90IF730.04-00 | X90 mobile IF option board, 3x CAN, 1x RS485, configuration using software |
X90IF7L0.05-00 | X90 mobile IF option board, 3x CAN, 2x LIN (master), configuration using software |
Condition Monitoring
X90CM480.04-00 | X90 mobile condition monitoring, option board for vibration measurement and vibration analysis of condition monitoring tasks, 4 IEPE analog inputs |
Digital inputs
X90DI110.10-00 | X90 mobile option board DI, 10 digital inputs, 9 to 32 VDC, optional sink/source, optional counter input 50 kHz or AB encoder, configuration using software |
Digital outputs
X90PO210.08-00 | X90 mobile option board PWM, 8x PWM outputs, 9 to 32 VDC, max. 4 A, with current measurement (12-bit), 15 Hz to 1 kHz, optional DI, 9 to 32 VDC, sink/source, configuration using software |
X90RO440.05-00 | X90 mobile option board relay, 5 relays, normally open contact, for external actuator power supply, 9 to 32 VDC / 2 A |
Motor modules
X90SM546.02-01 | X90 stepper motor module, with current reduction function, module power supply 15 to 32 VDC, 2 motor connections,4 A continuous current, 8 A peak current, NetTime function |
Safe digital outputs
X90RO440.04-S1 | Carte optionnelle mobile X90 avec sorties relais sécurisées, 4 relais, contacts normalement ouverts, pour alimentation externe de l'actionneur, 9 à 32 VDC / 2 et 4 A |
Temperature measurement
X90AT910.04-00 | X90 mobile option board AT, 4 resistance measurement inputs, Pt1000, optional DI, 9 to 32 VDC, sink/source, optional AI, 0 to 10 V / 0 to 32 V, 0 to 20 mA, optional PWM output, 9 to 32 VDC, 10 mA, 1 kHz, configuration using software |
X90AT910.08-00 | X90 mobile option board AT, 8 resistance measurement inputs, Pt1000, optional DI, 9 to 32 VDC, sink/source, optional AI, 0 to 10 V / 0 to 32 V, 0 to 20 mA, optional PWM output, 9 to 32 VDC, 10 mA, 1 kHz, configuration using software |
Wire harness
X90CA100.02-00 | X90 mobile 170, faisceau de câbles, kit de démarrage pour X90CP17x, 2 m, pour l'en-tête CMC |
Automation Studio HW Upgrades | Version (date) | Téléchargement |
---|---|---|
V4.3 HW Upgrade (X90CP172.48-00) | EXE / 4 Mo | |
V4.7 HW Upgrade (X90CP172.48-00) | EXE / 5 Mo | |
V4.9 HW Upgrade (X90CP172.48-00) | EXE / 5 Mo | |
V6.0 HW Upgrade (X90CP172.48-00) | EXE / 6 Mo |
Documentation | Version (date) | Téléchargement |
---|---|---|
Datasheet X90CP172.xx-00 | PDF / 10 Mo | |
Open Source Licenses X90CPxxxx | ZIP / 1 Mo | |
X90 mobile System User´s Manual | PDF / 49 Mo | |
X90 pin allocation CMC connector | ZIP / 3 Mo |
E-CAD (modèles Electro ou EPLAN) | Version (date) | Téléchargement |
---|---|---|
X90 EPLAN P8 from V2.4 | EXE / 69 Mo |
M-CAD (modèles mécaniques) | Version (date) | Téléchargement |
---|---|---|
3D File STEP X90CP172.xx-00 | ZIP / 9 Mo |