1.7.0.0 * 01/10/2024 1 MB EXE AS6_HW_X20DO8232.exe
Description V6.0 HW Upgrade (X20DO8232)

Revision information X20DO8232

Version 1.7.0.0:

ID: TDYD-7029
Incorrectly configured modules were not identified on the X2X bus in certain circumstances.
A dynamic hardwareconfiguration is used for various customer applications. In this case, a default configuration is simply created in AS and the actual configuration is readout after the system has started up. Due to a hardware change of several I/O modules, only a cyclic size of 12 bytes (previously 31 bytes) is accepted in the bootloader. If a module with more cyclic data (e.g. a safety module) is nowconfigured, this module can no longer be identified on the bus. As a workaround, these "large" modules can be configured on other X2X slots. This problem can only be corrected with a new bootloader, which can only be delivered via production. Production will be switched to the new software accordingly.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\42157_10.fw(150), 1\42157_11.fw(150), 1\42157_20.fw(200), 1\42157_21.fw(230), 1\42157_5.fw(801)

Version 1.6.0.0:

ID: 760740
Support new HW variant 21
Channel descriptionchanged: No
Configuration description changed: No
Firmware changed:Yes
Firmware: 1\42157_10.fw(150), 1\42157_11.fw(150), 1\42157_20.fw(200), 1\42157_21.fw(210), 1\42157_5.fw(801)

Version 1.5.0.0:

ID: 738545
Support new HW variant 20
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\42157_10.fw(150), 1\42157_11.fw(150), 1\42157_20.fw(200), 1\42157_5.fw(801)

Version 1.4.0.0:

ID:
Adaptations for Automation Studio 4.11
Channel description changed: no
Configuration description changed: yes
Firmware changed: no

Version 1.3.0.0:

ID: 676555
Support hardware variant 11
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware:1\42157_10.fw(150), 1\42157_11.fw(150), 1\42157_5.fw(801)

Version 1.2.0.0:

ID:
Adaptations for Automation Studio 4.8
Channel description changed: no
Configuration description changed: yes
Firmwarechanged: no

Version 1.1.0.0:

ID: 631795
Support hardwarevariant 10
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 632650
Module documentation revised
Data sheet V2.15
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\42157_10.fw(100), 1\42157_5.fw(801)

Version 1.0.3.0:

ID:467200
Module documentation revised
Data sheet V 3.12
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\42157_5.fw(801)

Version 1.0.2.3:

ID: 394970
Enhancement online-help files
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\42157_5.fw(801)

Version 1.0.2.2:

ID: 394230
Enhancements packed data point for outputs
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No
Firmware: 1\42157_5.fw(801)

Version 1.0.2.1:

ID: 333275
Correction of data point StatusDigitalOutput08
Data point corrected whenused in function model 254.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No
Firmware: 1\42157_5.fw(801)

Version 1.0.2.0:

ID: 256450
Increase interference immunity of output status feedbacks
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\42157_5.fw(801)

Version 1.0.1.1:

ID: 215990
Support of asynchronous module status data points
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No
Firmware: 1\42157_5.fw(784)

Version 1.0.1.0:

ID: 185090
HWC correction, correct display of PS status
HWC correction, correct display of PS status if dig. status=off
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\42157_5.fw(784)

Version 1.0.0.0:

ID: 171240
First revision
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\42157_5.fw(784)