DWL@DWL10000801559
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
---|---|---|---|---|---|---|
1.6.3.0 | * | 17/10/2024 | 23 Mo | EXE | AS6_HW_8I74xxxxxxx.01P-1.exe | |
Description |
V6.0 HW Upgrade (8I74xxxxxxx.01P-1) Revision information 8I74xxxxxxx.01P-1 Version 1.6.3.0: ID: AHBM-241 Legacy flag has been set The ACOPOSinverter P74/P74new is at the end of its life cycle. Hence, the legacy flag has been set with this version. After the installation, the button to show the legacy modules is required to show the module in hardware catalog. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\49819_1.fw(600) Version 1.6.2.0: ID: 695275 External error detection revised The error message EPF1 does not have to be acknowledged after a restart - even not if the external error detection is used in low active mode. Channel description changed: No Configuration description changed: No Firmwarechanged: No ID: 735655 Additional optional datapoints In respect to the different memory allocation in the ACPi P74new, two additional datapoints are implemented that can be used optionally to transmit the serial number of the drive. Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\49819_1.fw(600) Version 1.6.1.0: ID: 657425 Download of project revised If the drive is used with setting Supervised="on" and the AutomationSutidioproject is downloaded, there is no further warm start necessary anymore. Channel description changed: No Configuration description changed:No Firmware changed: No ID: 665520 Download of Parameter "FFT" revised The parameter "FFT" can be used to define the threshold value of the reference frequency for all conducted stop ramps. In order to controlthe stop ramps as long as possible, the value for parameter "FFT" is set to its minimum (default setting). The valid minimum value of parameter "FFT" depends on the set value for nominal motor frequency. That is why the parameter will be downloaded only, if the defined value in the module configuration (AutomationStudio) is set to a value different from "2". Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\49819_1.fw(600) Version 1.6.0.0: ID: Adaptations for Automation Studio 4.8 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.5.0.1: ID: 608425 Asynchronous behavior of POERLINK interface revised The receive buffer for asynchronous POWERLINK frames was extended. Thus, SDO massages can be received, which were split into frames with more than 600 byte by the POWERLINK master. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 649635 Configuration view revised Der displayed text of parameter DCCM was changed in order to ensure an error-free project build with older AutomationStudio versions Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\49819_1.fw(600) Version 1.4.4.0: ID: 323335 Configuration parameters of intermediate circuit revised (part 2) The DC chaining mode (parameter "DCCM") can be defined in the configurationview und be downloaded to the device. Additional information: If necessary, the detection for ground shortcircuit (parameter "SCL3") is deactivated automatically according to "DCCM". The deactivation of ground short circuit detectionentails considerable risk. That is why parameter "SCL3" was not added to the configuration view. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 640265 Configuration parameters of intermediate circuit revised (part 1) Input and download of configuration parameters for undervoltage detection (parameters "URES"/"UPL"/"USL") were adapted to define them for 240V and 400V intermediate circuits. Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\49819_1.fw(506) Version 1.4.3.0: ID:619535 Management of internal register "OPL1" corrected The hidden register "OPL1" was removed from the HWX file. Now, it is managed exclusively by the inverter's firmware. The malicious OPL1 extension impaired the setting of the OPL function "output phase loss". It was contained in thefollowing versions: 1.4.1.0 and 1.4.2.0. Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\49819_1.fw(506) Version 1.4.2.0: ID: 614345 Syntax error in initialisation script eliminated Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\49819_1.fw(506) Version 1.4.1.0: ID: 568290 Parameter download revised (Configuration of IOs; R1, R2, LO1, AO1/DO1) The download procedure was adapted in order to define the behavior of the IOs on the terminal block by using the IO configuration of Automation Studio. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 585400 General revision of download procedure In some cases valid parameter sets from AutomationStudio were refused by thedrive because a CFI error was detected. The download procedure was adapted according to the CFI error detection. Channel description changed: No Configuration description changed: No Firmware changed: No ID: 595740 Parameter download revised (Configuration of tuning parameters; synchronousmotor) The download procedure was adapted in order to set tuningparameters for synchronous motors by using the IO configuration of AutomationStudio. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 599255 Module documentation revised User manual V 2.40 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\49819_1.fw(506) Version 1.4.0.0: ID: 516280 Module documentation revised User manual V 2.30 Channel description changed:No Configuration description changed: No Firmware changed: No ID: 549285 Timing problem during SDO write eliminated In order to ensure a proper handshake on POWERLINK command layer, the acknowledge behavior for SDO write commands was revised. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 564440 Misbehavoir during firmware update was eliminated The automatic download for exchanging the firmware can be guaranteed when using versions 502...503. --> The misbehavoir effects especially POWERLINK communication card for ACPi P74 with hardware revision C3 and C6 because they were equipped with firmware 503 as BOOT firmware. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 565420 Parameter download for FRS, TFR, HSP, LSP was revised The order of downloading FRS, TFR, HSP, LSP was optimized. Channel description changed: No Configuration description changed: No Firmware changed: No ID: 579850 Problem during built of Automation Studio project eliminated. The device can be configured as "Multiplexed Station" on POWERLINK Bus. Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\49819_1.fw(506) Version 1.3.1.0: ID: 511555 Function models renamed no influence to technical behavior Functions model "default"/"legacy" renamed to "Direct control" Functions model "default (MotionConfiguration)"/"default" renamed to "ACP10SDC (MotionConfiguration)" Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 541625 Internal revision Inverter can be used as multiplexed station in AS4 project. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 542135 Assignment configurations for physical outputs (AO, DO, LO, R) revised Physical outputs can be used with function blocks. CAUTION: Connection has to be defined on physical output and corresponding function block. CAUTION: Connections on physical output DO1 overwrite connections on physicaloutput AO1. Channel description changed: No Configuration description changed: No Firmware changed: No ID: 543115 CSLOUT data points (OCC, LLC) revised The appication functions OCC and LLC can be configured to DO1, LO1 or R2. Furthermore data points EBO and TSY of application function traverse conmtrol have been corrected similarly. Channel description changed: No Configuration description changed: Yes Firmware changed:No Firmware: 1\49819_1.fw(503) Version 1.3.0.0: ID: 489235 Behavior of SDC_LifeCnt restored The module firmware 502 (contained in hardware upgrades 1.2.x.x) limited the answering speed of datapoint SDC_LifeCnt. This unacceptable Limitation was eliminated. Hence the functions of ACP10 manager can also be used with POWERLINK cycles from 400 µs to 1999 µs. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\49819_1.fw(503) Version 1.2.0.1: ID: 485210 Value ranges revised The value ranges of TFR, HSP, LSP, UNS, NSPS and SPF can be defined in IO-Configuration according to parameterlist (Excel). Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\49819_1.fw(502) Version 1.2.0.0: ID: 304265 Ringredundancy Firmwareupgrade to support ringredundancy. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 340785 Datapoint CMI_Output_Bool_00 removed The BOOLean datapoint CMI_Output_Bool_00 was removed. Reason: The inverter switches to error state "TRAP" when using this datapointcyclically. Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 380405 SDO timeout revised Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 409480 Module configuration extended The configuration parameters LO1F and AOF1 have been added. LO1F and AOF1 can be used to define the behavior of the hardware outputs in case of an error. Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes ID: 426830 Parameter access for HSC datapoint extented HSC datapoint 16#2067; 16#9 can be accessed acyclically. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\49819_1.fw(502) Version 1.1.8.5: ID: 344825 Parameter AI2L added to I/O configuration AI2L can be configured independently from AI1L. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 346070 General review of HW files Missing texts/textparts in HW file for AS4.x restored. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 347790 View in System Designer revised. The product picture was exchange and scaled. Channel description changed: No Configuration description changed: No Firmware changed: No ID: 350625 Parameter AUT removed., because this function is not supported by the I/O configuration. The Parameter AUT was removed from the configuration view of Automation Studios. Reason: After activating the function "automatic autotune" the inverter doesnot execute the demanded rutine. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 358340 Option CT of Parameter TUNU removed The Option CT of Parameter TUNU was removed from the configuration view of Automation Studios. Reason: After configurating the option "cold tune" the inverter does not execute the demanded rutine. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 384955 Configuration paramters IDA, LFA and TRA revised. The Parameters IDA, LFA and TRA can be adjusted by IO configuration. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 443755 Configuration paramter INR activated The Parameter INR can beadjusted by IO configuration. Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\49819_1.fw(404) Version 1.1.5.0: ID: 336080 Faulty configuration attribute, configuration can not be written to drive. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 337815 Changed order of parameters transfer (LET, EFT) Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\49819_1.fw(404) Version 1.1.4.0: ID: 322415 Default values for SIT configuration Channel description changed: No Configuration description changed: No Firmware changed: No ID: 333115 The parameter R2 can not bewritten with the IO configuration Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware:1\49819_1.fw(404) Version 1.1.2.0: ID: 291695 With the configuration "Download parameters = no" all inverter configurations will be retained now. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 300870 ACOPOSinverter P74 does not response on PollRequest, when X20BC0083 in network Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 305565 SDC-LifeCnt does not count if Download parameters = "no" Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\49819_1.fw(404) Version 1.1.1.0: ID: 278665 Support ACOPOSinverter P74 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 284265 SDC support Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes ID: 284935 Module configuration optimized Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\49819_1.fw(403) |