Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
---|---|---|---|---|---|---|
1.5.0.0 | * | 01/02/2024 | 6 MB | EXE | AS4_HW_X90CP172.24-00.exe | |
Description |
V4.7 HW Upgrade (X90CP172.24-00) Revision information X90CP172.24-00 Version 1.5.0.0: ID: 780585 Error in AB counter mode fixed. When a channel was configured as "Digital input source", the "Counter" Register was not reset to zero after reboot. Channel description changed:No Configuration description changed: No Firmware changed: Yes Firmware: 1\60334_1.fp(32), 2\60334_1.fp(54) Version 1.4.6.0: ID: 762065 / Support ID: 400392864 X2X bus output cycle trigger error correction The X2X bus output cycle trigger was not started although it wasconfigured. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\60334_1.fp(24), 2\60334_1.fp(50) Version 1.4.4.0: ID: 729190 / Support ID: 400352024 Support for 6 A current on parallel channels When two 6 A channels are used in parallel mode, a total current of 12 A isnow possible. Attention: When using 4 A and 6 A channels in parallel, each channel can only supply 4 A. Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\60334_1.fp(24), 2\60334_1.fp(50) Version 1.4.3.0: ID: 714635 Module documentation revised Data sheet V1.90 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\60334_1.fp(24), 2\60334_1.fp(50) Version 1.4.1.0: ID: 710700 Add "DeviceID" and "DeviceSerialNumber" to IO Map Using the entries "DeviceID" and "DeviceSerialNumber" the serial and id of the device can now be usedin the IO map. Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\60334_1.fp(24), 2\60334_1.fp(50) Version 1.4.0.0: ID: 684695 Module documentation revised Data sheet V1.81 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 685890 Module documentation revised Data sheet V1.81 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 703140 Enables second CPU core for I/O processing The I/O input processing can be assigned to the the second CPU core.This frees CPU processing power to be used by the application. Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\60334_1.fp(24), 2\60334_1.fp(50) Version 1.3.1.0: ID: 694885 Support data point StorageWear, wear level of storage medium starting fromAR A4.90 Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\60334_1.fp(24), 2\60334_1.fp(50) Version 1.3.0.0: ID: 693000 Enable TFTP server To enable a firmware update for mobilepanels, the TFTP Server must be activated. Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\60334_1.fp(24), 2\60334_1.fp(50) Version 1.2.4.0: ID: 673575 Description of "Total Current" changed to 0-45 A Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\60334_1.fp(24), 2\60334_1.fp(50) Version 1.2.3.0: ID: 668095 AS4.8 Enhancement CPU configuration: Lossof remanent data Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\60334_1.fp(24), 2\60334_1.fp(50) Version 1.2.2.0: ID: 656125 Improved I/O Minimal requirements AS version 4.7.1 and AR 4.71 New functions: Analogue Channels Resistor measurement 0-50 kOhm Temperature measurement PT1000 Current measurement: 4-20 mA DigitalOutput Channels: Adjustable maximum current 0-4 A PWM Channels: H-Bridge mode Dithering Adjustable maximum current 0-4 A / 0-6 A up to 4 kHz in PWM mode, up to 8 kHz im H-brigde mode Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\60334_1.fp(24), 2\60334_1.fp(50) Version 1.0.3.0: ID: 617575 / Support ID: 400261388 Corrupted CAN messages on IF9 (CAN3) With heavy load on the processor interfacea "race condition" may exist on the CAN control for IF9 (CAN3). As a result, the register access and the data access may interfere. For solving this "race condition" a locking mechanism hasbeen added, that allows data access to the CAN component only after the configuration via register accesses have been finished. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 620290 / Support ID: 400249041 Improve help on Sensor Supply status. Channel description changed:No Configuration description changed: No Firmware changed: No Firmware: 1\60334_1.fp(24) Version 1.0.2.0: ID: 573925 Support X90CP172.24-00 Important Remark: To use the help, a minimum version 4.3.5.24 of the Automation Studio Main Help is required. Otherwise the upgrade is installed, but the help pages are empty. In case you installed the upgrade in the wrong order, you must first uninstall the Main Help using the Windows Control Panel, install the Main Help again and then apply the Module Upgrade. Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\60334_1.fp(23) |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
1.4.6.0 | * | 15/11/2022 | 6 MB | EXE | AS4_HW_X90CP172.24-00.exe | |
Description |
V4.7 HW Upgrade (X90CP172.24-00) Revision information X90CP172.24-00 Version 1.4.6.0: ID: 762065 / Support ID: 400392864 X2X bus output cycle trigger error correction The X2X bus output cycle trigger was not started although it was configured. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\60334_1.fp(24), 2\60334_1.fp(50) Version 1.4.4.0: ID: 729190 / Support ID: 400352024 Support for 6 A current on parallel channels When two 6 A channels are used in parallel mode, a total current of12 A is now possible. Attention: When using 4 A and 6 A channels in parallel,each channel can only supply 4 A. Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\60334_1.fp(24), 2\60334_1.fp(50) Version 1.4.3.0: ID: 714635 Module documentation revised Data sheet V1.90 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\60334_1.fp(24), 2\60334_1.fp(50) Version 1.4.1.0: ID: 710700 Add "DeviceID" and "DeviceSerialNumber" to IO Map Using the entries "DeviceID" and "DeviceSerialNumber" the serial and id of the device can now be used in the IO map. Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\60334_1.fp(24), 2\60334_1.fp(50) Version 1.4.0.0: ID: 684695 Module documentation revised Data sheet V1.81 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 685890 Module documentation revised Data sheet V1.81 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 703140 Enablessecond CPU core for I/O processing The I/O input processing can be assigned to the the second CPU core. This frees CPU processing power to be used by the application. Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\60334_1.fp(24), 2\60334_1.fp(50) Version 1.3.1.0: ID: 694885 Support data point StorageWear, wear level of storage medium starting fromAR A4.90 Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\60334_1.fp(24), 2\60334_1.fp(50) Version 1.3.0.0: ID: 693000 Enable TFTP server To enable a firmware update for mobile panels, the TFTP Server must be activated. Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\60334_1.fp(24), 2\60334_1.fp(50) Version 1.2.4.0: ID: 673575 Description of "Total Current" changed to 0-45 A Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\60334_1.fp(24), 2\60334_1.fp(50) Version 1.2.3.0: ID: 668095 AS4.8 Enhancement CPU configuration: Loss of remanent data Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\60334_1.fp(24), 2\60334_1.fp(50) Version 1.2.2.0: ID: 656125 Improved I/O Minimal requirements AS version 4.7.1 and AR 4.71 New functions: Analogue Channels Resistor measurement 0-50 kOhm Temperature measurement PT1000 Current measurement: 4-20 mA Digital Output Channels: Adjustable maximum current 0-4 A PWM Channels: H-Bridge mode Dithering Adjustable maximum current 0-4 A / 0-6 A up to 4 kHz in PWM mode, upto 8 kHz im H-brigde mode Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\60334_1.fp(24), 2\60334_1.fp(50) Version 1.0.3.0: ID: 617575 / Support ID: 400261388 Corrupted CAN messages on IF9 (CAN3) With heavy load on the processor interface a "race condition" may exist on the CAN control for IF9 (CAN3). As a result, the register access and the data access may interfere. For solving this "race condition" a locking mechanism has been added, that allows data access to the CAN component only after the configuration via register accesses have been finished. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 620290 / Support ID: 400249041 Improve help on Sensor Supply status. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\60334_1.fp(24) Version 1.0.2.0: ID: 573925 Support X90CP172.24-00 Important Remark: To use the help, a minimum version 4.3.5.24 of the Automation Studio Main Help is required. Otherwise the upgrade is installed, but the help pages are empty.In case you installed the upgrade in the wrong order, you must first uninstall the Main Help using the Windows Control Panel, installthe Main Help again and then apply the Module Upgrade. Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\60334_1.fp(23) |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
1.4.4.0 | * | 02/09/2021 | 6 MB | EXE | AS4_HW_X90CP172.24-00.exe | |
Description |
V4.7 HW Upgrade (X90CP172.24-00) Revision information X90CP172.24-00.24-00 Version 1.4.4.0: ID: 729190 / Support ID: 400352024 Support for 6 A current on parallel channels When two 6 A channels are used in parallel mode, a total current of 12 A isnow possible. Attention: When using 4 A and 6 A channels in parallel, each channel can only supply 4 A. Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\60334_1.fp(24), 2\60334_1.fp(50) Version 1.4.3.0: ID: 714635 Module documentation revised Data sheet V1.90 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\60334_1.fp(24), 2\60334_1.fp(50) Version 1.4.1.0: ID: 710700 Add "DeviceID" and "DeviceSerialNumber" to IO Map Using the entries "DeviceID" and "DeviceSerialNumber" the serial and id of the device can now be used in the IO map. Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\60334_1.fp(24), 2\60334_1.fp(50) Version 1.4.0.0: ID: 684695 Module documentationrevised Data sheet V1.81 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 685890 Module documentation revised Data sheet V1.81 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 703140 Enables second CPU core for I/O processing The I/O input processing can be assigned to the the second CPU core. This frees CPU processing power to be used by the application. Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\60334_1.fp(24), 2\60334_1.fp(50) Version 1.3.1.0: ID: 694885 Support data point StorageWear, wear level of storage medium starting fromAR A4.90 Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\60334_1.fp(24), 2\60334_1.fp(50) Version 1.3.0.0: ID: 693000 Enable TFTP server To enable a firmware update for mobile panels,the TFTP Server must be activated. Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\60334_1.fp(24), 2\60334_1.fp(50) Version 1.2.4.0: ID: 673575 Description of "Total Current" changed to 0-45 A Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\60334_1.fp(24), 2\60334_1.fp(50) Version 1.2.3.0: ID: 668095 AS4.8 Enhancement CPU configuration: Loss of remanent data Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\60334_1.fp(24), 2\60334_1.fp(50) Version 1.2.2.0: ID: 656125 Improved I/O Minimal requirements AS version 4.7.1 and AR 4.71 New functions: Analogue Channels Resistor measurement 0-50 kOhm Temperaturemeasurement PT1000 Current measurement: 4-20 mA Digital Output Channels: Adjustable maximum current 0-4 A PWM Channels: H-Bridge mode Dithering Adjustable maximum current 0-4 A / 0-6 A up to 4 kHz in PWM mode, up to 8 kHz im H-brigde mode Channeldescription changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\60334_1.fp(24), 2\60334_1.fp(50) Version 1.0.3.0: ID: 617575 / Support ID: 400261388 Corrupted CAN messages on IF9 (CAN3) With heavy load on the processor interface a "racecondition" may exist on the CAN control for IF9 (CAN3). As a result, the register access and the data access may interfere. For solving this "race condition" a locking mechanism hasbeen added, that allows data access to the CAN component only after the configuration via register accesses have been finished. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 620290 / Support ID: 400249041 Improve help on Sensor Supply status. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\60334_1.fp(24) Version 1.0.2.0: ID: 573925 Support X90CP172.24-00 Important Remark: To use the help, a minimum version 4.3.5.24 of the Automation Studio Main Help is required. Otherwise the upgrade is installed, but the help pages are empty. In case you installed the upgrade in the wrong order, you must first uninstall the Main Help using the Windows Control Panel, install the Main Help again and then apply the Module Upgrade. Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\60334_1.fp(23) |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
1.4.3.0 | * | 08/02/2021 | 6 MB | EXE | AS4_HW_X90CP172.24-00.exe | |
Description |
V4.7 HW Upgrade (X90CP172.24-00) Revision information X90CP172.24-00.24-00 Version 1.4.3.0: ID: 714635 Module documentation revised Data sheet V1.90 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\60334_1.fp(24), 2\60334_1.fp(50) Version 1.4.1.0: ID: 710700 Add "DeviceID" and "DeviceSerialNumber" to IO Map Using the entries "DeviceID" and "DeviceSerialNumber" the serial and id of the device can now be used in the IO map. Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\60334_1.fp(24), 2\60334_1.fp(50) Version 1.4.0.0: ID: 684695 Module documentation revised Data sheet V1.81 Channel description changed: No Configuration description changed: No Firmware changed: No ID:685890 Module documentation revised Data sheet V1.81 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 703140 Enables second CPU core for I/O processing The I/O input processing can be assigned to the the second CPU core. This frees CPU processing power to be used by the application. Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\60334_1.fp(24), 2\60334_1.fp(50) Version 1.3.1.0: ID: 694885 Support data point StorageWear, wear levelof storage medium starting from AR A4.90 Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\60334_1.fp(24), 2\60334_1.fp(50) Version 1.3.0.0: ID: 693000 Enable TFTP server To enable a firmware update for mobile panels, the TFTP Server must be activated. Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\60334_1.fp(24), 2\60334_1.fp(50) Version 1.2.4.0: ID: 673575 Description of "Total Current" changed to 0-45 A Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\60334_1.fp(24), 2\60334_1.fp(50) Version 1.2.3.0: ID: 668095 AS4.8 Enhancement CPU configuration: Loss of remanent data Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\60334_1.fp(24),2\60334_1.fp(50) Version 1.2.2.0: ID: 656125 Improved I/O Minimal requirements AS version 4.7.1 and AR 4.71 New functions: Analogue Channels Resistor measurement 0-50 kOhm Temperature measurement PT1000 Current measurement: 4-20 mA Digital Output Channels: Adjustable maximum current 0-4 A PWM Channels: H-Bridge mode Dithering Adjustable maximum current 0-4 A / 0-6 A up to 4 kHz in PWM mode, up to 8 kHz im H-brigde mode Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\60334_1.fp(24), 2\60334_1.fp(50) Version 1.0.3.0: ID: 617575 / Support ID: 400261388 Corrupted CAN messages on IF9 (CAN3) With heavy load on the processor interface a "race condition" may exist on the CAN control for IF9 (CAN3). As a result, the register access and the data access may interfere. For solving this "race condition" a locking mechanism has been added, that allows data access to the CAN component only after the configuration via register accesses have been finished. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 620290 / Support ID: 400249041 Improve help on Sensor Supply status. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\60334_1.fp(24) Version 1.0.2.0: ID: 573925 Support X90CP172.24-00 Important Remark: To use the help, a minimum version 4.3.5.24 of the Automation Studio Main Help is required. Otherwise the upgrade is installed, but the help pages are empty. In case you installed the upgrade in the wrong order, you must first uninstall the Main Help using the Windows Control Panel, install the Main Help again and then apply the Module Upgrade. Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\60334_1.fp(23) |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
1.3.1.0 | * | 11/09/2020 | 5 MB | EXE | AS4_HW_X90CP172.24-00.exe | |
Description |
V4.7 HW Upgrade (X90CP172.24-00) Revision information X90CP172.24-00 Version 1.3.1.0: ID: 694885 Support data point StorageWear, wear level of storage medium starting fromAR A4.90 Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\60334_1.fp(24), 2\60334_1.fp(50) Version 1.3.0.0: ID: 693000 Enable TFTP server To enable a firmware updatefor mobile panels, the TFTP Server must be activated. Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\60334_1.fp(24), 2\60334_1.fp(50) Version 1.2.4.0: ID: 673575 Description of "Total Current" changed to 0-45 A Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\60334_1.fp(24), 2\60334_1.fp(50) Version 1.2.3.0: ID: 668095 AS4.8 Enhancement CPU configuration: Loss of remanent data Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\60334_1.fp(24), 2\60334_1.fp(50) Version 1.2.2.0: ID: 656125 Improved I/O Minimal requirements AS version 4.7.1 and AR 4.71 New functions: Analogue Channels Resistor measurement 0-50 kOhm Temperature measurement PT1000 Current measurement: 4-20 mA Digital Output Channels: Adjustable maximum current 0-4 A PWM Channels: H-Bridge mode Dithering Adjustable maximum current 0-4 A / 0-6 A up to 4 kHz in PWM mode, up to 8 kHz im H-brigde mode Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\60334_1.fp(24), 2\60334_1.fp(50) Version 1.0.3.0: ID: 617575 / Support ID: 400261388 Corrupted CAN messages on IF9 (CAN3) With heavy load on the processor interface a "race condition" may exist on the CAN control for IF9 (CAN3). Asa result, the register access and the data access may interfere. For solving this "race condition" a locking mechanism hasbeen added, that allows data access to the CAN component only after the configuration via register accesses have been finished. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 620290 / Support ID: 400249041 Improve help on Sensor Supply status. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\60334_1.fp(24) Version 1.0.2.0: ID: 573925 Support X90CP172.24-00 Important Remark: To use the help, a minimum version 4.3.5.24 of the Automation Studio Main Help is required. Otherwise the upgrade is installed, but the help pages are empty. In case you installed the upgrade in the wrong order, you must first uninstall the Main Help using the Windows Control Panel, install the Main Help again and then apply the Module Upgrade. Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\60334_1.fp(23) |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
1.2.4.0 | * | 09/01/2020 | 5 MB | EXE | AS4_HW_X90CP172.24-00.exe | |
Description |
V4.7 HW Upgrade (X90CP172.24-00) Revision information X90CP172.24-00 Version 1.2.4.0: ID: 673575 Description of "Total Current"changed to 0-45 A Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\60334_1.fp(24), 2\60334_1.fp(50) Version 1.2.3.0: ID: 668095 AS4.8 Enhancement CPU configuration: Loss of remanent data Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\60334_1.fp(24), 2\60334_1.fp(50) Version 1.2.2.0: ID: 656125 Improved I/O Minimal requirements AS version 4.7.1 and AR 4.71 New functions: Analogue Channels Resistormeasurement 0-50 kOhm Temperature measurement PT1000 Current measurement: 4-20 mA Digital Output Channels: Adjustable maximum current 0-4 A PWM Channels: H-Bridge mode Dithering Adjustable maximum current 0-4 A / 0-6 A up to 4 kHz in PWM mode, up to 8 kHz im H-brigde mode Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\60334_1.fp(24), 2\60334_1.fp(50) Version 1.0.3.0: ID: 617575 / Support ID: 400261388 Corrupted CAN messages on IF9 (CAN3) With heavyload on the processor interface a "race condition" may exist on the CAN control for IF9 (CAN3). As a result, the register access and the data access may interfere. For solving this "race condition" a locking mechanism hasbeen added,that allows data access to the CAN component only after the configuration viaregister accesses have been finished. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 620290 / Support ID: 400249041 Improve help on Sensor Supply status. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\60334_1.fp(24) Version 1.0.2.0: ID: 573925 Support X90CP172.24-00 Important Remark: To use the help, a minimum version 4.3.5.24 of the Automation Studio Main Helpis required. Otherwise the upgrade is installed, but thehelp pages are empty. In case you installed the upgrade in the wrong order, you must first uninstall the Main Help using the Windows Control Panel, installthe Main Help again and then apply the Module Upgrade. Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\60334_1.fp(23) |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
1.2.2.0 | * | 18/09/2019 | 5 MB | EXE | AS4_HW_X90CP172.24-00.exe | |
Description |
V4.7 HW Upgrade (X90CP172.24-00) Revision information X90CP172.24-00 Version 1.2.2.0: ID: 656125 Improved I/O Minimal requirements AS version 4.7.1 and AR 4.71 New functions: Analogue Channels Resistor measurement 0-50 kOhm Temperature measurementPT1000 Current measurement: 4-20 mA Digital Output Channels: Adjustable maximum current 0-4 A PWM Channels: H-Bridge mode Dithering Adjustable maximum current 0-4 A / 0-6 A up to 4 kHz in PWM mode, up to 8 kHz im H-brigde mode Channel descriptionchanged: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\60334_1.fp(24), 2\60334_1.fp(50) Version 1.2.1.0: ID: 656125 Improved I/O New functions: Analogue Channels Resistor measurement 0-50 kOhm Temperature measurement PT1000 Current measurement: 4-20 mA Digital Output Channels: Adjustable maximum current 0-4 A PWM Channels: H-Bridge mode Dithering Adjustable maximum current 0-4 A / 0-6 A up to 4 kHz in PWM mode, up to 8 kHz im H-brigde mode Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\60334_1.fp(24), 2\60334_1.fp(50) Version 1.0.3.0: ID: 617575 / Support ID: 400261388 Corrupted CAN messages onIF9 (CAN3) With heavy load on the processor interface a "race condition"may exist on the CAN control for IF9 (CAN3). As a result, the register accessand the data access may interfere. For solving this "race condition" a locking mechanism has been added, that allows data access to the CAN component only after the configuration via register accesses have been finished. Channeldescription changed: No Configuration description changed: No Firmware changed: Yes ID: 620290 / Support ID: 400249041 Improve helpon Sensor Supply status. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\60334_1.fp(24) Version 1.0.2.0: ID: 573925 Support X90CP172.24-00 Important Remark: To use the help, a minimum version 4.3.5.24 of the Automation Studio Main Help is required. Otherwise the upgrade is installed, but the help pages are empty. In case you installed the upgrade in the wrong order, you must first uninstall the Main Help using the Windows Control Panel, install the Main Help again and then apply the Module Upgrade. Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\60334_1.fp(23) |