DWL@DWL10000349443
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
---|---|---|---|---|---|---|
1.7.0.0 | * | 23/07/2021 | 3 Mo | EXE | AS4_HW_X20RT8001.exe | |
Description |
V4.1 HW Upgrade (X20RT8001) Revision information X20RT8001 Version 1.7.0.0: ID: Adaptations for Automation Studio 4.11 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.6.1.0: ID: 687470 Limitation of the cycle time Channel description changed: No Configuration description changed: No Firmware changed: No ID: 689455 Module documentation revised Data sheet V 1.25 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58713_2.fw(430), 1\58713_3.fw(430), 1\58713_4.fw(430) Version 1.6.0.0: ID: 650580 Additional status bit for rtiABRPos reference impulse loss An additional status bit was introduced, that detects the loss of the reference impulse signals. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58713_2.fw(430), 1\58713_3.fw(430), 1\58713_4.fw(430) Version 1.5.0.0: ID: Adaptations for Automation Studio 4.8 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.4.0.0: ID: 623545 Bootup time significantly increases with upgrade V1.3.0.0 of X20RT8001 Bootup time has been improved Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58713_2.fw(420), 1\58713_3.fw(420), 1\58713_4.fw(420) Version 1.3.1.0: ID:601825 Correction HWX-File Parameter specification corrected Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58713_2.fw(420), 1\58713_3.fw(420), 1\58713_4.fw(420) Version 1.3.0.0: ID: 594335 Support new hwvariante 4 with fw v420 Solving bootup problems Channel descriptionchanged: No Configuration description changed: No Firmware changed:Yes ID: 594890 Added configuration "blackout mode" Channeldescription changed: No Configuration description changed: Yes Firmware changed: No ID: 600635 Module documentation revised Data sheet V 1.23 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58713_2.fw(420), 1\58713_3.fw(420), 1\58713_4.fw(420) Version 1.2.0.0: ID: 587355 / Support ID: 400247572 Correction of the functionality of the timestamp outputs Behavour of the timestamp Bit0 flags of CntTs and LatchTs outputs corrected Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 591710 Module documentation revised Data sheet V 1.22 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58713_2.fw(420), 1\58713_3.fw(420) Version 1.1.1.0: ID: 530765 Module documentation revised Data sheet V 1.20 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58713_2.fw(320), 1\58713_3.fw(320) Version 1.1.0.0: ID: 471685 Harmonization of all reACTION modules Harmonization of hardwarefiles for similar usage and easier maintenance. Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 478590 Module documentation revised Data sheet V1.10 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 483495 Execution of functionblocks rtiPWM und rtiDiv revised. The functions blocks rtiPWM and rtiDiv do not cause a timing error, when they are used as first instruction in the in reACTION task. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58713_2.fw(320), 1\58713_3.fw(320) Version 1.0.1.0: ID:463510 Module documentation revised Data sheet V 1.04 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 469860 Correction Channel-Description Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\58713_2.fw(200), 1\58713_3.fw(200) Version 1.0.0.0: ID: 426115 Support X20RT8001 Support for Automation Studio Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58713_2.fw(200), 1\58713_3.fw(200) |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
1.6.1.0 | * | 10/06/2020 | 3 Mo | EXE | AS4_HW_X20RT8001.exe | |
Description |
V4.1 HW Upgrade (X20RT8001) Revision information X20RT8001 Version 1.6.1.0: ID: 687470 Limitation of the cycle time Channel description changed: No Configuration description changed: No Firmware changed: No ID: 689455 Module documentation revised Data sheet V 1.25 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58713_2.fw(430), 1\58713_3.fw(430), 1\58713_4.fw(430) Version 1.6.0.0: ID: 650580 Additional status bit for rtiABRPos reference impulse loss An additional status bit was introduced, that detects the loss of the reference impulse signals. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58713_2.fw(430), 1\58713_3.fw(430), 1\58713_4.fw(430) Version 1.5.0.0: ID: Adaptations for Automation Studio 4.8 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.4.0.0: ID: 623545 Bootup time significantly increases withupgrade V1.3.0.0 of X20RT8001 Bootup time has been improved Channeldescription changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58713_2.fw(420), 1\58713_3.fw(420), 1\58713_4.fw(420) Version 1.3.1.0: ID: 601825 Correction HWX-File Parameter specification corrected Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58713_2.fw(420), 1\58713_3.fw(420), 1\58713_4.fw(420) Version 1.3.0.0: ID: 594335 Support new hw variante 4 with fw v420 Solving bootup problems Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 594890 Added configuration "blackout mode" Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 600635 Module documentation revised Data sheet V 1.23 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58713_2.fw(420), 1\58713_3.fw(420), 1\58713_4.fw(420) Version 1.2.0.0: ID: 587355 / Support ID: 400247572 Correction of the functionality of the timestamp outputs Behavour of the timestamp Bit0 flags of CntTs and LatchTs outputs corrected Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 591710 Module documentation revised Data sheet V 1.22 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58713_2.fw(420), 1\58713_3.fw(420) Version 1.1.1.0: ID: 530765 Module documentation revised Data sheet V 1.20 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58713_2.fw(320), 1\58713_3.fw(320) Version 1.1.0.0: ID: 471685 Harmonization of all reACTION modules Harmonization of hardwarefiles for similar usage and easier maintenance. Channel description changed:Yes Configuration description changed: No Firmware changed: No ID: 478590 Module documentation revised Data sheet V1.10 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 483495 Execution of functionblocks rtiPWM und rtiDiv revised. The functions blocks rtiPWM and rtiDiv do not cause a timing error, when they are used as first instruction in the in reACTION task. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58713_2.fw(320), 1\58713_3.fw(320) Version 1.0.1.0: ID: 463510 Module documentationrevised Data sheet V 1.04 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 469860 Correction Channel-Description Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\58713_2.fw(200), 1\58713_3.fw(200) Version 1.0.0.0: ID: 426115 Support X20RT8001 Support for Automation Studio Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58713_2.fw(200), 1\58713_3.fw(200) |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
1.6.0.0 | * | 16/01/2020 | 3 Mo | EXE | AS4_HW_X20RT8001.exe | |
Description |
V4.1 HW Upgrade (X20RT8001) Revision information X20RT8001 Version 1.6.0.0: ID: 650580 Additional status bit for rtiABRPos reference impulse loss An additional status bit was introduced, that detects the loss of the reference impulse signals. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58713_2.fw(430), 1\58713_3.fw(430), 1\58713_4.fw(430) Version 1.5.0.0: ID: Adaptations for Automation Studio 4.8 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.4.0.0: ID: 623545 Bootup time significantly increases with upgrade V1.3.0.0 of X20RT8001 Bootup time has been improved Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58713_2.fw(420), 1\58713_3.fw(420), 1\58713_4.fw(420) Version 1.3.1.0: ID: 601825 Correction HWX-File Parameter specification corrected Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58713_2.fw(420), 1\58713_3.fw(420), 1\58713_4.fw(420) Version 1.3.0.0: ID: 594335 Support new hw variante 4 with fw v420 Solving bootup problems Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 594890 Added configuration "blackout mode" Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 600635 Module documentation revised Data sheet V 1.23 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58713_2.fw(420), 1\58713_3.fw(420), 1\58713_4.fw(420) Version 1.2.0.0: ID: 587355 / Support ID: 400247572 Correction of the functionality of the timestamp outputs Behavour of the timestamp Bit0 flags of CntTs and LatchTs outputscorrected Channel description changed: No Configuration descriptionchanged: No Firmware changed: Yes ID: 591710 Module documentation revised Data sheet V 1.22 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58713_2.fw(420), 1\58713_3.fw(420) Version 1.1.1.0: ID: 530765 Module documentation revised Data sheet V 1.20 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58713_2.fw(320), 1\58713_3.fw(320) Version 1.1.0.0: ID: 471685 Harmonization of all reACTION modules Harmonization of hardwarefiles for similar usage and easier maintenance. Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 478590 Module documentation revised Data sheet V1.10 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 483495 Execution of functionblocks rtiPWM und rtiDiv revised. The functions blocks rtiPWM and rtiDiv do not cause a timing error, when they are used as first instruction in the in reACTION task. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58713_2.fw(320), 1\58713_3.fw(320) Version 1.0.1.0: ID: 463510 Module documentation revised Data sheet V 1.04 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 469860 Correction Channel-Description Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\58713_2.fw(200), 1\58713_3.fw(200) Version 1.0.0.0: ID: 426115 Support X20RT8001 Support for Automation Studio Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58713_2.fw(200),1\58713_3.fw(200) |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
1.5.0.0 | * | 25/10/2019 | 3 Mo | EXE | AS4_HW_X20RT8001.exe | |
Description |
V4.1 HW Upgrade (X20RT8001) Revision information X20RT8001 Version 1.5.0.0: ID: Adaptations for Automation Studio 4.8 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.4.0.0: ID: 623545 Bootup time significantly increases with upgrade V1.3.0.0 of X20RT8001 Bootup time has been improved Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58713_2.fw(420), 1\58713_3.fw(420), 1\58713_4.fw(420) Version 1.3.1.0: ID: 601825 Correction HWX-File Parameter specification corrected Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58713_2.fw(420), 1\58713_3.fw(420), 1\58713_4.fw(420) Version 1.3.0.0: ID: 594335 Support new hw variante 4 with fw v420 Solving bootup problems Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 594890 Added configuration "blackout mode" Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 600635 Module documentation revised Data sheet V 1.23 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58713_2.fw(420), 1\58713_3.fw(420), 1\58713_4.fw(420) Version 1.2.0.0: ID: 587355 / Support ID: 400247572 Correction of the functionality of the timestamp outputs Behavour of the timestamp Bit0 flags of CntTs and LatchTs outputs corrected Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 591710 Module documentation revised Data sheet V 1.22 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58713_2.fw(420), 1\58713_3.fw(420) Version 1.1.1.0: ID: 530765 Module documentation revised Data sheet V 1.20 Channeldescription changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58713_2.fw(320), 1\58713_3.fw(320) Version 1.1.0.0: ID: 471685 Harmonization of all reACTION modules Harmonization of hardwarefiles for similar usage and easier maintenance. Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 478590 Module documentation revised Data sheet V1.10 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 483495 Execution of functionblocks rtiPWM und rtiDiv revised. The functions blocks rtiPWM and rtiDiv do not cause a timing error, when they are used as firstinstruction in the in reACTION task. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58713_2.fw(320), 1\58713_3.fw(320) Version 1.0.1.0: ID: 463510 Module documentation revised Data sheet V 1.04 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 469860 Correction Channel-Description Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\58713_2.fw(200), 1\58713_3.fw(200) Version 1.0.0.0: ID: 426115 Support X20RT8001 Support forAutomation Studio Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58713_2.fw(200), 1\58713_3.fw(200) |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
1.4.0.0 | * | 18/12/2018 | 3 Mo | EXE | AS4_HW_X20RT8001.exe | |
Description |
V4.1 HW Upgrade (X20RT8001) Revision information X20RT8001 Version 1.4.0.0: ID: 623545 Bootup time significantly increases withupgrade V1.3.0.0 of X20RT8001 Bootup time has been improved Channeldescription changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58713_2.fw(420), 1\58713_3.fw(420), 1\58713_4.fw(420) Version 1.3.1.0: ID: 601825 Correction HWX-File Parameter specification corrected Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58713_2.fw(420), 1\58713_3.fw(420), 1\58713_4.fw(420) Version 1.3.0.0: ID: 594335 Support new hw variante 4 with fw v420 Solving bootup problems Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 594890 Added configuration "blackout mode" Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 600635 Module documentation revised Data sheet V 1.23 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58713_2.fw(420), 1\58713_3.fw(420), 1\58713_4.fw(420) Version 1.2.0.0: ID: 587355 / Support ID: 400247572 Correction of the functionality of the timestamp outputs Behavour of the timestamp Bit0 flags of CntTs and LatchTs outputs corrected Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 591710 Module documentation revised Data sheet V 1.22 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58713_2.fw(420), 1\58713_3.fw(420) Version 1.1.1.0: ID: 530765 Module documentation revised Data sheet V 1.20 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58713_2.fw(320), 1\58713_3.fw(320) Version 1.1.0.0: ID: 471685 Harmonization of all reACTION modules Harmonization of hardwarefiles for similar usage and easier maintenance. Channel description changed:Yes Configuration description changed: No Firmware changed: No ID: 478590 Module documentation revised Data sheet V1.10 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 483495 Execution of functionblocks rtiPWM und rtiDiv revised. The functions blocks rtiPWM and rtiDiv do not cause a timing error, when they are used as first instruction in the in reACTION task. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58713_2.fw(320), 1\58713_3.fw(320) Version 1.0.1.0: ID: 463510 Module documentationrevised Data sheet V 1.04 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 469860 Correction Channel-Description Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\58713_2.fw(200), 1\58713_3.fw(200) Version 1.0.0.0: ID: 426115 Support X20RT8001 Support for Automation Studio Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58713_2.fw(200), 1\58713_3.fw(200) |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
1.3.1.0 | * | 10/08/2018 | 3 Mo | EXE | AS4_HW_X20RT8001.exe | |
Description |
V4.1 HW Upgrade (X20RT8001) Revision information X20RT8001 Version 1.3.1.0: ID: 601825 Correction HWX-File Parameter specification corrected Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58713_2.fw(420), 1\58713_3.fw(420), 1\58713_4.fw(420) Version 1.3.0.0: ID: 594335 Support new hw variante 4 with fw v420 Solving bootup problems Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 594890 Added configuration "blackout mode" Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 600635 Module documentation revised Data sheet V 1.23 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58713_2.fw(420), 1\58713_3.fw(420), 1\58713_4.fw(420) Version 1.2.0.0: ID: 587355 / Support ID: 400247572 Correction of the functionality of the timestamp outputs Behavour of the timestamp Bit0 flags of CntTs and LatchTs outputs corrected Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 591710 Module documentation revised Data sheet V 1.22 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58713_2.fw(420), 1\58713_3.fw(420) Version 1.1.1.0: ID: 530765 Module documentation revised Datasheet V 1.20 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58713_2.fw(320), 1\58713_3.fw(320) Version 1.1.0.0: ID: 471685 Harmonizationof all reACTION modules Harmonization of hardwarefiles for similar usageand easier maintenance. Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 478590 Module documentation revised Data sheet V1.10 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 483495 Execution of functionblocks rtiPWM und rtiDiv revised. The functions blocks rtiPWM and rtiDiv do not cause a timing error, when they are used as first instruction in the in reACTION task. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58713_2.fw(320), 1\58713_3.fw(320) Version 1.0.1.0: ID: 463510 Module documentation revised Data sheet V 1.04 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 469860 Correction Channel-Description Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\58713_2.fw(200), 1\58713_3.fw(200) Version 1.0.0.0: ID: 426115 Support X20RT8001 Support for Automation Studio Channel description changed:No Configuration description changed: No Firmware changed: No Firmware: 1\58713_2.fw(200), 1\58713_3.fw(200) |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
1.3.0.0 | * | 28/06/2018 | 3 Mo | EXE | AS4_HW_X20RT8001.exe | |
Description |
V4.1 HW Upgrade (X20RT8001) Revision information X20RT8001 Version 1.3.0.0: ID: 594335 Support new hw variante 4 with fw v420 Solving bootup problems Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 594890 Added configuration "blackout mode" Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 600635 Module documentation revised Data sheet V 1.23 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58713_2.fw(420), 1\58713_3.fw(420), 1\58713_4.fw(420) Version 1.2.0.0: ID: 587355 / Support ID: 400247572 Correction of the functionality of the timestamp outputs Behavour of the timestamp Bit0 flags of CntTs and LatchTs outputs corrected Channeldescription changed: No Configuration description changed: No Firmware changed: Yes ID: 591710 Module documentation revised Data sheet V 1.22 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58713_2.fw(420), 1\58713_3.fw(420) Version 1.1.1.0: ID: 530765 Module documentation revised Data sheet V 1.20 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58713_2.fw(320), 1\58713_3.fw(320) Version 1.1.0.0: ID: 471685 Harmonization of all reACTION modules Harmonization of hardwarefiles for similar usage and easier maintenance. Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 478590 Module documentation revised Data sheet V1.10 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 483495 Execution of functionblocks rtiPWM und rtiDiv revised. The functions blocks rtiPWM and rtiDiv do not cause a timing error, when they are used as first instruction in the in reACTION task. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58713_2.fw(320), 1\58713_3.fw(320) Version 1.0.1.0: ID: 463510 Module documentation revised Data sheet V 1.04 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 469860 Correction Channel-Description Channel description changed:Yes Configuration description changed: No Firmware changed: No Firmware: 1\58713_2.fw(200), 1\58713_3.fw(200) Version 1.0.0.0: ID: 426115 Support X20RT8001 Support for Automation Studio Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58713_2.fw(200), 1\58713_3.fw(200) |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
1.2.0.0 | * | 24/04/2018 | 2 Mo | EXE | AS4_HW_X20RT8001.exe | |
Description |
V4.1 HW Upgrade (X20RT8001) Revision information X20RT8001 Version 1.2.0.0: ID: 587355 / Support ID: 400247572 Correction of the functionality of the timestamp outputs Behavour of the timestamp Bit0 flags of CntTs and LatchTs outputs corrected Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 591710 Module documentation revised Data sheet V 1.22 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58713_2.fw(420), 1\58713_3.fw(420) Version 1.1.1.0: ID: 530765 Module documentation revised Data sheet V 1.20 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58713_2.fw(320), 1\58713_3.fw(320) Version 1.1.0.0: ID: 471685 Harmonization of all reACTION modules Harmonization of hardwarefiles for similar usage and easier maintenance. Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 478590 Module documentation revised Data sheet V1.10 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 483495 Execution of functionblocks rtiPWM und rtiDiv revised. The functions blocks rtiPWM and rtiDiv do not cause a timing error, when they are used as first instruction in the in reACTION task. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58713_2.fw(320), 1\58713_3.fw(320) Version 1.0.1.0: ID: 463510 Module documentation revised Data sheet V 1.04 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 469860 Correction Channel-Description Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\58713_2.fw(200), 1\58713_3.fw(200) Version 1.0.0.0: ID: 426115 Support X20RT8001 Support for Automation Studio Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58713_2.fw(200), 1\58713_3.fw(200) |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
1.1.1.0 | * | 02/05/2017 | 2 Mo | EXE | AS4_HW_X20RT8001.exe | |
Description |
V4.1 HW Upgrade (X20RT8001) Revision information X20RT8001 Version 1.1.1.0: ID: 530765 Module documentation revised Data sheet V 1.20 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58713_2.fw(320), 1\58713_3.fw(320) Version 1.1.0.0: ID: 471685 Harmonization of all reACTION modules Harmonization of hardwarefiles for similar usage and easier maintenance. Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 478590 Module documentation revised Data sheet V1.10 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 483495 Execution of functionblocks rtiPWM und rtiDiv revised. The functions blocks rtiPWM and rtiDiv do not cause a timing error, when they are used as first instruction in the in reACTION task. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58713_2.fw(320), 1\58713_3.fw(320) Version 1.0.1.0: ID: 463510 Module documentation revised Data sheet V 1.04 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 469860 Correction Channel-Description Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\58713_2.fw(200),1\58713_3.fw(200) Version 1.0.0.0: ID: 426115 Support X20RT8001 Support for Automation Studio Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58713_2.fw(200), 1\58713_3.fw(200) |