Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
---|---|---|---|---|---|---|
1.15.0.0 | * | 23/06/2022 | 1 Mo | EXE | AS4_HW_X20IF1082-2.exe | |
Description |
V4.0 HW Upgrade (X20IF1082-2) Revision information X20IF1082-2 Version 1.15.0.0: ID: 753135 POWERLINK Manager Type 3 und 4 If a CN with the parameter NMTCNSoC2PReq set was operated in a network withPOWERLINK Manager type 3 and 4, this could lead to the error "20803 POWERLINK: A fatal error has occurred" if network disturbances occurred. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(36365), 1\42915_1.pci(36360), 1\42915a0.epl(142), 1\42915a1.epl(142) Version 1.14.0.0: ID: 735705 Update problem If the firmware update of the interface card was interrupted (e.g. by a power failure), it was possible that the interface was no longer booted by Automation Runtime. This problem can only occur with interfaces with revisions ≥ F0 and when the hardware upgrade is changed. To correct this problem, it is necessary to switch to another hardware upgrade. This will force an update or use this current hardware upgrade. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(36364), 1\42915_1.pci(36359), 1\42915a0.epl(142), 1\42915a1.epl(142) Version 1.13.0.0: ID: Adaptations for Automation Studio 4.11 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.12.0.0: ID: 705080 POWERLINK: Operating mode "Ethernet" If a POWERLINK interface was operated in operating mode "Ethernet" and connected to a POWERLINK network in this mode, the interface could fail. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(36364), 1\42915_1.pci(36357), 1\42915a0.epl(142), 1\42915a1.epl(142) Version 1.11.1.0: ID: 692860 Support HW variant 1 Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 693970 Support for automatic DNA configuration from AS 4.9.1 Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\42915_0.pci(36108), 1\42915_1.pci(36101), 1\42915a0.epl(141), 1\42915a1.epl(141) Version 1.10.0.0: ID: 614145 / Support ID: 400286104, 400289594 POWERLINK: Possible failure of already configured CNs if new "chained stations" added during operation Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 644020 Error correction: DNA tree topologies not always started up correctly Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(35852), 1\42915a0.epl(140) Version 1.9.0.0: ID: 636510 POWERLINK-Manager: With frequent failure of CN's, which are operated with the optimization "Chained station" it can be happen that failed CN's were not longer adressed by the manager. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(35340), 1\42915a0.epl(138) Version 1.8.0.0: ID: 591100 Documentation updated Version 1.23 Channel descriptionchanged: No Configuration description changed: No Firmware changed:No ID: 597825 Cannot connect hardware module to PLK2 interface of X20IF1082-2 in Ethernetmode in AS Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 603490 / Support ID: 400250890 POWERLINK CNs with configuration "Optimization: Minimal latency": No input data received POWERLINK CNs with configuration "Optimization: Minimal latency" and "Chained station: On" that are not physically present in the network can cause no input data to be received from all CNs with setting "Optimization: Minimal latency". Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(34825), 1\42915a0.epl(136) Version 1.7.0.0: ID: 568865 Support HW-Revision DO Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(34313), 1\42915a0.epl(134) Version1.6.0.0: ID: 539750 / Support ID: 400204420 POWERLINK V2: no asynchronous frames in mode NMT PRE_OPERATIONAL_1 Because of a timing problem in the firmware it could happen that no asynchronous frames were sent in the mode PRE_OPERATIONAL_1 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(33545), 1\42915a0.epl(131) Version 1.5.0.0: ID: 503425 X20-Compact-S support Channel description changed: No Configuration description changed: No Firmware changed: No ID: 504200 Documentation updated version 1.22 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42915_0.pci(32777), 1\42915a0.epl(128) Version 1.4.0.0: ID: 443850 / Support ID: 400154848 IP packets with multicast addresses not received by the POWERLINK interface Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(32777), 1\42915a0.epl(128) Version 1.3.0.0: ID: 394180 / Support ID: 400135055 Support of Poll Response Chaining oniCN Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 410330 / Support ID: 400141340 POWERLINK: Switch to Basic Ethernet of ICN at fail of MN For POWERLNK ICN a switch to basic ethernet mode was build it, so that after a fail of the POWERLINK MN the ICN station could communicate by standard ethernet. In the POWERLINK Standard this state change is not described yet. Now this feature hat to be enabled explicitly therefore the standard behavior of ICN conforms to the POWERLINK specification. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 417925 Support Bonding feature Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 424025 / Support ID: 400138730 POWERLINK V2: "Controlled node" mode In networks with heavy SoC jitter, the dropping out of an SoC sometimes caused a permanent freezing of the input data on the controlled node. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 424100 / Support ID: 400150240 POWERLINK V2: "Controlled node" mode After a POWERLINK manager failed, the controlled node sometimes registered with an incorrect NMT status in the ident response. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(32521), 1\42915a0.epl(127) Version 1.2.3.0: ID: 358955 POWERLINK MN mode: If "Multiplexing prescale" >= 9, then the input data of the multiplexed stations that were configured in the last "network cycle" were not transferred in certain configurations. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 359175 / Support ID: 400113446 POWERLINK V2 MN mode: Asynchronous connection losses may occur as a result of high asynchronous loads on the POWERLINK network and high loads on the CPU. This could maintain you to an error 32205 Timeout while writing par. via acyclic channel. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID:360195 POWERLINK V1 MN mode Error correction: Cyclic input data andnet time toggle between the last tworeceived values when CNs drop out. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 360250 / Support ID: - POWERLINK V1 MN mode: "Nettime SoC" is not increased. Channel description changed: No Configuration description changed: No Firmware changed: Yes Version 1.2.2.0: ID: 300415 POWERLINK V2 MN mode: It was possible that an undefined state occurred during booting that causedthe interface to fail. Channel description changed: No Configuration descriptionchanged: No Firmware changed: Yes ID: 331355 / Support ID: 400092134 POWERLINK V1: If the "Activate Ethernet communication off" option is enabled, asynchronous POWERLINK communication fails in some circumstances. The following configuration may cause asynchronous communication to fail: - POWERLINK V1 - "Activate Ethernet communication off" - POWERLINK CNs on the network that also support POWERLINK V2 This upgrade can beinstalled to resolve this problem. It is also possible to set "Activate Ethernet communication" to "On". Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 337465 /Support ID: 400108118 POWERLINK V2 CN mode It was possible that an undefined state occurred during booting that causedthe interface to fail. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(30726), 1\42915a0.epl(120) Version 1.2.1.0: ID: 274800 Support of 'Multiple Asynchronous Send' Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 285960 POWERLINKV2 CN mode: Asynchronous packets lost when there is a large asynchronous loadwith large asynchronous frames. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(29702), 1\42915a0.epl(116) Version 1.2.0.0: ID: 264230 POWERLINK V2: Large fluctuations of IEEE 1588 Nettime (used for safety logbook entries) during startup. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(29702), 1\42915a0.epl(116) Version 1.1.0.2: ID: 256790 / Support ID: 400057319 POWERLINK: In controlled node mode, theI/O mapping was not applied when themanager was restarted. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 256945 POWERLINK: The net time is not always transferred correctly to the application. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 265770 POWERLINK V2 CN mode: Frequent MN failures result in CPU going into Servicemode. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 265915 POWERLINK V2: If the the Ready-Flag was canceled on the network, the ModuleOK was not cleared. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 265870 Warning 32168 "POWERLINK V2: Invalid frame format" on iCN with "Chaned Station" on the same network Error correction: When an iCN is used in the same POWERLINK network with a "Chained Station", there may be warnings 32168 in the logger. The reason for this warning is that the sync response frames that are used tomeasure the timing of the "Chained Station" are not recognized by the iCN. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(28677), 1\42915a0.epl(112) Version 1.0.2.0: ID: 233570 Correction of interchanged LinkOK data points in AS IO mapping Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 234660 New POWERLINK firmware V106 POWERLINK V2 chained stations:Reconnecting failed stations improved. LinkOK Datapoint in Operating Mode 'Ethernet' available. Channel description changed: Yes Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(27140), 1\42915a0.epl(106) Version 1.0.1.0: ID: 229290 POWERLINK V2 chained stations: When stations that have failed are added back into the POWERLINK cycle, active chained stations fail. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(26883), 1\42915a0.epl(105) Version 1.0.0.0: ID: 194235 Support of X20IF1082-2 Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\42915_0.pci(26114), 1\42915a0.epl(102) |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
1.14.0.0 | * | 17/02/2022 | 1 Mo | EXE | AS4_HW_X20IF1082-2.exe | |
Description |
V4.0 HW Upgrade (X20IF1082-2) Revision information X20IF1082-2 Version 1.14.0.0: ID: 735705 Update problem If the firmware update of the interface card was interrupted (e.g. by a power failure), it was possible that the interface was no longer booted by Automation Runtime. This problem can only occur with interfaces with revisions # F0 and when the hardware upgrade is changed. To correct this problem, it is necessary to switch to another hardware upgrade. This will force an update or use this current hardware upgrade. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(36364), 1\42915_1.pci(36359), 1\42915a0.epl(142), 1\42915a1.epl(142) Version 1.13.0.0: ID: Adaptations for Automation Studio 4.11 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.12.0.0: ID: 705080 POWERLINK: Operating mode "Ethernet" If a POWERLINK interface was operated in operating mode "Ethernet" and connected to a POWERLINK network in this mode,the interface could fail. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(36364), 1\42915_1.pci(36357), 1\42915a0.epl(142), 1\42915a1.epl(142) Version 1.11.1.0: ID: 692860 Support HW variant 1 Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 693970 Support for automatic DNA configuration from AS 4.9.1 Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\42915_0.pci(36108), 1\42915_1.pci(36101), 1\42915a0.epl(141), 1\42915a1.epl(141) Version 1.10.0.0: ID: 614145 / Support ID: 400286104, 400289594 POWERLINK: Possible failure of already configured CNs if new "chained stations"added during operation Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 644020 Error correction: DNA tree topologies not always started up correctly Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(35852), 1\42915a0.epl(140) Version 1.9.0.0: ID: 636510 POWERLINK-Manager: With frequent failure of CN's, which are operated with the optimization "Chained station"it can be happen that failed CN's were not longer adressed by the manager. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(35340), 1\42915a0.epl(138) Version 1.8.0.0: ID: 591100 Documentation updated Version 1.23 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 597825 Cannot connect hardware module to PLK2 interface of X20IF1082-2 in Ethernetmode in AS Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 603490 / Support ID: 400250890 POWERLINK CNs with configuration "Optimization: Minimal latency": No input data received POWERLINK CNs with configuration "Optimization: Minimal latency" and "Chained station: On" that are not physically present in the network can cause no input data to be received from all CNs with setting "Optimization: Minimal latency". Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(34825), 1\42915a0.epl(136) Version 1.7.0.0: ID: 568865 Support HW-Revision DO Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(34313), 1\42915a0.epl(134) Version 1.6.0.0: ID: 539750 / Support ID: 400204420 POWERLINK V2: no asynchronous frames in mode NMT PRE_OPERATIONAL_1 Because of a timing problem in the firmware it could happen that no asynchronous frames were sent in the mode PRE_OPERATIONAL_1 Channeldescription changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(33545), 1\42915a0.epl(131) Version 1.5.0.0: ID: 503425 X20-Compact-S support Channeldescription changed: No Configuration description changed: No Firmware changed: No ID: 504200 Documentation updated version 1.22 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42915_0.pci(32777), 1\42915a0.epl(128) Version 1.4.0.0: ID: 443850 / Support ID: 400154848 IP packets with multicast addresses not received by the POWERLINK interface Channel description changed: No Configuration description changed:No Firmware changed: Yes Firmware: 1\42915_0.pci(32777), 1\42915a0.epl(128) Version 1.3.0.0: ID: 394180 / Support ID: 400135055 Support of Poll Response Chaining on iCN Channel description changed:No Configuration description changed: No Firmware changed: Yes ID: 410330 / Support ID: 400141340 POWERLINK: Switch to Basic Ethernet of ICN at fail of MN For POWERLNK ICN a switch to basic ethernet mode was build it, so that after a fail of the POWERLINK MN the ICN station could communicate by standard ethernet. In the POWERLINK Standard this state change is not described yet. Now this feature hat to be enabled explicitly therefore the standard behavior of ICN conforms to the POWERLINK specification. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 417925 Support Bonding feature Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 424025 / Support ID: 400138730 POWERLINKV2: "Controlled node" mode In networks with heavy SoC jitter, the dropping out of an SoC sometimes caused a permanent freezing of the input data on the controlled node. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 424100 / Support ID: 400150240 POWERLINK V2: "Controlled node" mode After a POWERLINKmanager failed, the controlled node sometimes registered with an incorrect NMT status in the ident response. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(32521), 1\42915a0.epl(127) Version 1.2.3.0: ID: 358955 POWERLINK MN mode: If "Multiplexing prescale" >= 9, then theinput data of the multiplexed stations that were configured in the last "network cycle" were not transferred in certain configurations. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 359175 / Support ID: 400113446 POWERLINK V2 MN mode: Asynchronous connection losses may occur as a result of high asynchronous loads on the POWERLINK network and high loads on the CPU. This could maintain you to an error 32205 Timeout while writing par. via acyclic channel. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 360195 POWERLINK V1 MN mode Error correction: Cyclic input data and net time toggle between the last two received values when CNs drop out. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 360250 / Support ID: - POWERLINK V1 MN mode: "Nettime SoC" is not increased. Channel description changed: No Configuration description changed: No Firmware changed: Yes Version 1.2.2.0: ID: 300415 POWERLINK V2 MN mode: It was possible that an undefined state occurredduring booting that caused the interface to fail. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 331355 / Support ID: 400092134 POWERLINK V1: If the "Activate Ethernet communication off" option is enabled, asynchronous POWERLINK communication fails in some circumstances. The following configuration may cause asynchronous communication to fail: - POWERLINK V1 - "Activate Ethernet communication off" - POWERLINK CNs on the network that also supportPOWERLINK V2 This upgrade can be installed to resolve this problem. Itis also possible to set "Activate Ethernet communication" to "On". Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 337465 / Support ID: 400108118 POWERLINK V2 CN mode It was possible that an undefined state occurred during booting that causedthe interface to fail. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(30726), 1\42915a0.epl(120) Version 1.2.1.0: ID: 274800 Support of 'Multiple Asynchronous Send' Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 285960 POWERLINK V2 CN mode: Asynchronous packets lostwhen there is a large asynchronous load with large asynchronous frames. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(29702), 1\42915a0.epl(116) Version 1.2.0.0: ID: 264230 POWERLINK V2: Large fluctuations of IEEE 1588 Nettime (used for safety logbook entries) during startup. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(29702), 1\42915a0.epl(116) Version 1.1.0.2: ID: 256790 / Support ID: 400057319 POWERLINK: In controlled node mode, the I/O mapping was not applied when the manager was restarted. Channel description changed: No Configurationdescription changed: No Firmware changed: Yes ID: 256945 POWERLINK: The net time is not always transferred correctly to the application. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 265770 POWERLINK V2 CN mode: Frequent MN failures result in CPU going into Servicemode. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 265915 POWERLINK V2: If the the Ready-Flag was canceled on the network, the ModuleOK was not cleared. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 265870 Warning 32168 "POWERLINK V2: Invalid frame format"on iCN with "Chaned Station" on the same network Error correction: When an iCN is used in the same POWERLINK network with a "Chained Station", there may be warnings 32168 in the logger. The reason for this warning is that the sync response frames that are used to measure the timing of the "Chained Station" are not recognized by the iCN. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(28677), 1\42915a0.epl(112) Version 1.0.2.0: ID: 233570 Correction of interchanged LinkOK data points in AS IO mapping Channel description changed: Yes Configuration description changed:No Firmware changed: No ID: 234660 New POWERLINK firmware V106 POWERLINK V2 chained stations: Reconnecting failed stations improved. LinkOK Datapoint in Operating Mode 'Ethernet' available. Channel description changed: Yes Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(27140), 1\42915a0.epl(106) Version 1.0.1.0: ID: 229290 POWERLINK V2 chained stations: Whenstations that have failed are added backinto the POWERLINK cycle, active chained stations fail. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(26883), 1\42915a0.epl(105) Version 1.0.0.0: ID: 194235 Support of X20IF1082-2 Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\42915_0.pci(26114), 1\42915a0.epl(102) |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
1.13.0.0 | * | 23/07/2021 | 1 Mo | EXE | AS4_HW_X20IF1082-2.exe | |
Description |
V4.0 HW Upgrade (X20IF1082-2) Revision information X20IF1082-2 Version 1.13.0.0: ID: Adaptations for Automation Studio 4.11 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.12.0.0: ID: 705080 POWERLINK: Operating mode "Ethernet" If a POWERLINK interface was operated in operating mode "Ethernet" and connected to a POWERLINK network in this mode, the interface could fail. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(36364), 1\42915_1.pci(36357), 1\42915a0.epl(142), 1\42915a1.epl(142) Version 1.11.1.0: ID: 692860 Support HW variant 1 Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 693970 Support for automatic DNA configuration from AS 4.9.1 Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\42915_0.pci(36108), 1\42915_1.pci(36101), 1\42915a0.epl(141), 1\42915a1.epl(141) Version 1.10.0.0: ID: 614145 / Support ID: 400286104, 400289594 POWERLINK: Possible failure of already configured CNs if new "chained stations" added during operation Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 644020 Error correction: DNA tree topologies not always started up correctly Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(35852), 1\42915a0.epl(140) Version 1.9.0.0: ID: 636510 POWERLINK-Manager: With frequent failure of CN's, which are operated with the optimization "Chained station" it can be happen that failed CN's were not longer adressed by the manager. Channel description changed: No Configuration description changed:No Firmware changed: Yes Firmware: 1\42915_0.pci(35340), 1\42915a0.epl(138) Version 1.8.0.0: ID: 591100 Documentation updated Version 1.23 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 597825 Cannot connect hardware module to PLK2 interface of X20IF1082-2 in Ethernetmode inAS Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 603490 / Support ID: 400250890 POWERLINK CNs with configuration "Optimization: Minimal latency": No inputdata received POWERLINK CNs with configuration "Optimization: Minimal latency" and "Chained station: On" that are not physically present in the network can cause no input data to be received from all CNs with setting "Optimization: Minimal latency". Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(34825), 1\42915a0.epl(136) Version 1.7.0.0: ID: 568865 Support HW-Revision DO Channel description changed: No Configurationdescription changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(34313), 1\42915a0.epl(134) Version 1.6.0.0: ID: 539750 / Support ID: 400204420 POWERLINK V2: no asynchronous frames in mode NMT PRE_OPERATIONAL_1 Because of a timing problem in the firmware it could happen that no asynchronous frames were sent in the mode PRE_OPERATIONAL_1 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(33545), 1\42915a0.epl(131) Version 1.5.0.0: ID: 503425 X20-Compact-S support Channel description changed: No Configuration description changed: No Firmware changed: No ID: 504200 Documentation updated version 1.22 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42915_0.pci(32777), 1\42915a0.epl(128) Version 1.4.0.0: ID: 443850 / Support ID: 400154848 IP packets with multicast addresses not received by the POWERLINK interface Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(32777), 1\42915a0.epl(128) Version 1.3.0.0: ID: 394180 / Support ID: 400135055 Support of Poll Response Chaining on iCN Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 410330 / Support ID: 400141340 POWERLINK: Switch to Basic Ethernet of ICN at fail of MN For POWERLNK ICN a switch to basic ethernet mode was build it, so that after a fail of the POWERLINK MN the ICN station could communicate by standard ethernet. In the POWERLINK Standard this state change is not described yet. Now this feature hat to be enabled explicitly therefore the standard behavior of ICN conforms to the POWERLINK specification. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 417925 Support Bonding feature Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 424025 / Support ID: 400138730 POWERLINK V2: "Controlled node" mode In networks with heavy SoC jitter, the dropping out of an SoC sometimes caused a permanent freezing of the input data on the controlled node. Channel description changed: No Configurationdescription changed: No Firmware changed: Yes ID: 424100 / Support ID: 400150240 POWERLINK V2: "Controlled node" mode After a POWERLINK manager failed, the controlled node sometimes registered with an incorrect NMT status in the ident response. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(32521), 1\42915a0.epl(127) Version 1.2.3.0: ID: 358955 POWERLINK MN mode: If "Multiplexing prescale" >= 9, thenthe input data of the multiplexed stations that were configured in the last "network cycle" were not transferred in certain configurations. Channel description changed: No Configuration description changed: No Firmwarechanged: Yes ID: 359175 / Support ID: 400113446 POWERLINK V2 MNmode: Asynchronous connection losses may occur as a result of high asynchronous loads on the POWERLINK network and high loads on the CPU. This could maintain you to an error 32205 Timeout while writing par. via acyclic channel. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 360195 POWERLINK V1 MN mode Error correction: Cyclic input data and net time toggle between the last two received values when CNs drop out. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 360250 / Support ID: - POWERLINK V1 MN mode: "Nettime SoC" is not increased. Channel description changed: No Configuration description changed: No Firmware changed: Yes Version 1.2.2.0: ID: 300415 POWERLINK V2 MN mode: It was possible that an undefined state occurred during booting that causedthe interface to fail. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 331355 / Support ID: 400092134 POWERLINK V1: If the "Activate Ethernet communication off" option is enabled, asynchronous POWERLINK communication fails in some circumstances. The following configuration may cause asynchronous communication to fail: - POWERLINK V1 - "Activate Ethernet communication off" - POWERLINK CNs on the network that also support POWERLINK V2 This upgrade can be installed to resolve this problem. It is also possible toset "Activate Ethernet communication" to "On". Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 337465 / Support ID: 400108118 POWERLINK V2 CN mode It was possible that an undefined state occurred during booting that causedthe interface to fail. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(30726), 1\42915a0.epl(120) Version 1.2.1.0: ID: 274800 Support of 'Multiple Asynchronous Send' Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 285960 POWERLINK V2 CN mode: Asynchronous packets lost when there is a large asynchronous load with large asynchronous frames. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(29702), 1\42915a0.epl(116) Version 1.2.0.0: ID: 264230 POWERLINK V2: Large fluctuations of IEEE 1588 Nettime (used for safety logbook entries) during startup. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(29702), 1\42915a0.epl(116) Version 1.1.0.2: ID: 256790 / Support ID: 400057319 POWERLINK: In controlled node mode, the I/O mapping was not applied when the manager was restarted. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 256945 POWERLINK: The net time is not always transferred correctly to the application. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 265770 POWERLINK V2 CN mode: Frequent MN failures result in CPU going into Servicemode. Channel description changed: No Configuration description changed: No Firmwarechanged: Yes ID: 265915 POWERLINK V2: If the the Ready-Flag wascanceled on the network, the ModuleOK was not cleared. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 265870 Warning 32168 "POWERLINK V2: Invalid frame format" on iCN with "Chaned Station" on the same network Error correction: When an iCN is used in the same POWERLINK network with a "Chained Station", there may be warnings 32168 in the logger. The reason for this warning is that the sync response frames that are used to measure the timing of the "Chained Station" are not recognized by the iCN. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(28677), 1\42915a0.epl(112) Version 1.0.2.0: ID: 233570 Correction of interchanged LinkOK data points in AS IO mapping Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 234660 New POWERLINK firmware V106 POWERLINK V2 chained stations: Reconnecting failed stations improved. LinkOK Datapoint in Operating Mode 'Ethernet' available. Channel description changed: Yes Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(27140), 1\42915a0.epl(106) Version 1.0.1.0: ID: 229290 POWERLINK V2 chained stations: When stations that have failed are added back into the POWERLINK cycle, activechained stations fail. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(26883), 1\42915a0.epl(105) Version 1.0.0.0: ID: 194235 Support of X20IF1082-2 Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\42915_0.pci(26114), 1\42915a0.epl(102) |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
1.12.0.0 | * | 28/01/2021 | 1 Mo | EXE | AS4_HW_X20IF1082-2.exe | |
Description |
V4.0 HW Upgrade (X20IF1082-2) Revision information X20IF1082-2-2 Version 1.12.0.0: ID: 705080 POWERLINK: Operating mode "Ethernet" If a POWERLINK interface was operated in operating mode "Ethernet" and connected to a POWERLINK network in this mode, the interface could fail. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(36364), 1\42915_1.pci(36357), 1\42915a0.epl(142), 1\42915a1.epl(142) Version 1.11.1.0: ID: 692860 Support HW variant 1 Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 693970 Support for automatic DNA configuration from AS 4.9.1 Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\42915_0.pci(36108), 1\42915_1.pci(36101),1\42915a0.epl(141), 1\42915a1.epl(141) Version 1.10.0.0: ID: 614145 / Support ID: 400286104, 400289594 POWERLINK: Possible failure of already configured CNs if new "chained stations" added during operation Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 644020 Error correction: DNA tree topologies not always started up correctly Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(35852), 1\42915a0.epl(140) Version 1.9.0.0: ID: 636510 POWERLINK-Manager: With frequent failure of CN's, which are operated with the optimization "Chained station" it can be happen that failed CN's were not longer adressed by the manager. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(35340), 1\42915a0.epl(138) Version 1.8.0.0: ID: 591100 Documentation updated Version 1.23 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 597825 Cannot connect hardware module to PLK2 interface of X20IF1082-2 in Ethernetmode in AS Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 603490 / Support ID: 400250890 POWERLINK CNs with configuration "Optimization: Minimal latency": No input data received POWERLINK CNs with configuration "Optimization: Minimal latency" and "Chained station: On" that are not physically present in the network can cause no input data to be received from all CNs with setting "Optimization: Minimal latency". Channeldescription changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(34825), 1\42915a0.epl(136) Version 1.7.0.0: ID: 568865 Support HW-Revision DO Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(34313), 1\42915a0.epl(134) Version 1.6.0.0: ID: 539750 / Support ID: 400204420 POWERLINKV2: no asynchronous frames in mode NMT PRE_OPERATIONAL_1 Because of a timing problem in the firmware it could happen that no asynchronous frames weresent in the mode PRE_OPERATIONAL_1 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(33545), 1\42915a0.epl(131) Version 1.5.0.0: ID: 503425 X20-Compact-S support Channel description changed: No Configuration description changed: No Firmware changed: No ID: 504200 Documentation updated version 1.22 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42915_0.pci(32777), 1\42915a0.epl(128) Version 1.4.0.0: ID: 443850 / Support ID: 400154848 IP packets with multicast addresses not received by the POWERLINK interface Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(32777), 1\42915a0.epl(128) Version 1.3.0.0: ID: 394180 / Support ID: 400135055 Support of Poll Response Chaining on iCN Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 410330 / Support ID: 400141340 POWERLINK: Switch to Basic Ethernet of ICN at fail of MN For POWERLNK ICN a switch to basic ethernet mode was build it, so that after a fail of the POWERLINK MN the ICN station could communicate by standard ethernet. In the POWERLINK Standard this state change is not described yet. Now this feature hat to be enabled explicitly therefore the standard behavior of ICN conforms to the POWERLINK specification. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 417925 Support Bonding feature Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 424025 / Support ID: 400138730 POWERLINK V2: "Controlled node" mode In networks with heavy SoC jitter, the dropping out of an SoC sometimes caused a permanent freezing of the input data on the controlled node. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 424100 / Support ID: 400150240 POWERLINK V2: "Controlled node" mode After a POWERLINK manager failed, the controlled node sometimes registered with an incorrect NMT status in the ident response. Channel description changed: No Configuration description changed:No Firmware changed: Yes Firmware: 1\42915_0.pci(32521), 1\42915a0.epl(127) Version 1.2.3.0: ID: 358955 POWERLINK MN mode: If "Multiplexing prescale" >= 9, then the input data of the multiplexedstations that were configured in the last "network cycle" were not transferred in certain configurations. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 359175 / Support ID: 400113446 POWERLINK V2 MN mode: Asynchronous connection losses may occur as a result of high asynchronous loads on the POWERLINK network and high loads on the CPU. This could maintain you to an error 32205 Timeout while writing par. via acyclic channel. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 360195 POWERLINK V1 MN mode Error correction: Cyclic input data and net time toggle between the last two received values when CNs drop out. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 360250 / Support ID: - POWERLINK V1 MN mode: "Nettime SoC" is not increased. Channel description changed: No Configuration description changed: No Firmware changed: Yes Version 1.2.2.0: ID: 300415 POWERLINK V2 MN mode: It was possible that an undefined state occurred during booting that causedthe interface to fail. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 331355 / Support ID: 400092134 POWERLINK V1: If the "Activate Ethernet communication off" option is enabled, asynchronous POWERLINK communication fails in some circumstances. The following configuration may cause asynchronous communicationto fail: - POWERLINK V1 - "Activate Ethernet communication off" - POWERLINK CNs on the network that also support POWERLINK V2 This upgrade can be installed to resolve this problem. It is also possible toset "Activate Ethernet communication" to "On". Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 337465 / Support ID: 400108118 POWERLINK V2 CN mode It was possible that an undefined state occurred during booting that causedthe interface tofail. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(30726), 1\42915a0.epl(120) Version 1.2.1.0: ID: 274800 Support of 'Multiple Asynchronous Send' Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 285960 POWERLINK V2 CN mode: Asynchronous packets lost when there is a large asynchronous load with large asynchronous frames. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(29702), 1\42915a0.epl(116) Version 1.2.0.0: ID: 264230 POWERLINK V2: Large fluctuations of IEEE 1588 Nettime (used for safety logbook entries) during startup. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(29702), 1\42915a0.epl(116) Version 1.1.0.2: ID: 256790 / Support ID: 400057319 POWERLINK: In controlled nodemode, the I/O mapping was not applied when themanager was restarted. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 256945 POWERLINK: The net time is not always transferred correctly to the application. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 265770 POWERLINK V2 CN mode: Frequent MN failures result in CPU going into Servicemode. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 265915 POWERLINK V2: If the the Ready-Flag was canceled on the network, the ModuleOK was not cleared. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 265870 Warning 32168 "POWERLINK V2: Invalid frame format" on iCN with "Chaned Station" on the same network Error correction: When an iCN is used in the same POWERLINK network with a "Chained Station", there may be warnings 32168 in the logger. The reason for this warning is that the sync response frames that are used to measure the timing of the "Chained Station" are not recognized by the iCN. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(28677), 1\42915a0.epl(112) Version 1.0.2.0: ID: 233570 Correction of interchanged LinkOK data points in AS IO mapping Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 234660 New POWERLINK firmware V106 POWERLINK V2 chainedstations: Reconnecting failed stations improved. LinkOK Datapoint in Operating Mode 'Ethernet' available. Channel description changed: Yes Configuration description changed: No Firmware changed: Yes Firmware:1\42915_0.pci(27140), 1\42915a0.epl(106) Version 1.0.1.0: ID:229290 POWERLINK V2 chained stations: When stations that have failed areadded backinto the POWERLINK cycle, active chained stations fail. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(26883), 1\42915a0.epl(105) Version 1.0.0.0: ID: 194235 Support of X20IF1082-2 Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\42915_0.pci(26114), 1\42915a0.epl(102) |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
1.11.1.0 | * | 09/07/2020 | 1 Mo | EXE | AS4_HW_X20IF1082-2.exe | |
Description |
V4.0 HW Upgrade (X20IF1082-2) Revision information X20IF1082-2 Version 1.11.1.0: ID: 692860 Support HW variant 1 Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 693970 Support for automatic DNA configuration from AS 4.9.1 Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\42915_0.pci(36108), 1\42915_1.pci(36101), 1\42915a0.epl(141), 1\42915a1.epl(141) Version 1.10.0.0: ID: 614145 / Support ID: 400286104, 400289594 POWERLINK: Possible failure of already configured CNs if new "chained stations" added during operation Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 644020 Errorcorrection: DNA tree topologies not always started up correctly Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(35852), 1\42915a0.epl(140) Version 1.9.0.0: ID: 636510 POWERLINK-Manager: With frequent failure of CN's, which are operated with the optimization "Chained station" it can be happen that failed CN's were not longer adressed by the manager. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(35340), 1\42915a0.epl(138) Version 1.8.0.0: ID: 591100 Documentation updated Version 1.23 Channel description changed: No Configuration descriptionchanged: No Firmware changed: No ID: 597825 Cannot connecthardware module to PLK2 interface of X20IF1082-2 in Ethernet mode in AS Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 603490 / Support ID: 400250890 POWERLINK CNs with configuration "Optimization: Minimal latency": No input data received POWERLINK CNs with configuration "Optimization: Minimal latency" and "Chained station: On" that are not physically present in the network can cause no input data to be received from all CNs with setting "Optimization: Minimal latency". Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(34825),1\42915a0.epl(136) Version 1.7.0.0: ID: 568865 Support HW-Revision DO Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(34313), 1\42915a0.epl(134) Version 1.6.0.0: ID: 539750 / Support ID:400204420 POWERLINK V2: no asynchronous frames in mode NMT PRE_OPERATIONAL_1 Because of a timing problem in the firmware it could happen that noasynchronous frames were sent in the mode PRE_OPERATIONAL_1 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(33545), 1\42915a0.epl(131) Version 1.5.0.0: ID: 503425 X20-Compact-S support Channel description changed: No Configuration description changed: No Firmware changed: No ID: 504200 Documentation updated version 1.22 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42915_0.pci(32777), 1\42915a0.epl(128) Version 1.4.0.0: ID: 443850 / Support ID: 400154848 IP packets with multicast addresses not received by the POWERLINK interface Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(32777), 1\42915a0.epl(128) Version 1.3.0.0: ID: 394180 / Support ID: 400135055 Support of Poll Response Chaining on iCN Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 410330 / Support ID: 400141340 POWERLINK: Switch to Basic Ethernet ofICN at fail of MN For POWERLNK ICN a switch to basic ethernet mode was build it, so that after a fail of the POWERLINK MN the ICN station could communicate by standard ethernet. In the POWERLINK Standard this state change is notdescribed yet. Now this feature hat to be enabled explicitly therefore the standard behavior of ICNconforms to the POWERLINK specification. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 417925 Support Bonding feature Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 424025 / Support ID: 400138730 POWERLINK V2: "Controlled node" mode In networks with heavy SoC jitter, the dropping out of an SoC sometimes caused a permanent freezing of the input data on the controlled node. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 424100 / Support ID: 400150240 POWERLINK V2: "Controlled node" mode After a POWERLINK manager failed, the controlled node sometimes registered with an incorrect NMT status in the ident response. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(32521), 1\42915a0.epl(127) Version 1.2.3.0: ID: 358955 POWERLINK MN mode: If "Multiplexing prescale" >= 9, then the input data of the multiplexed stations that were configured in the last "network cycle" were not transferred in certain configurations. Channel descriptionchanged: No Configuration description changed: No Firmware changed:Yes ID: 359175 / Support ID: 400113446 POWERLINK V2 MN mode: Asynchronous connection losses may occur as a result of high asynchronous loads on the POWERLINK network and high loads on the CPU. This could maintain you to an error 32205 Timeout while writing par. via acyclic channel. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 360195 POWERLINK V1 MN mode Error correction: Cyclic input data and net time toggle between the last two received values when CNs drop out. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 360250/ Support ID: - POWERLINK V1 MN mode: "Nettime SoC" is not increased. Channel description changed: No Configuration description changed: No Firmware changed: Yes Version 1.2.2.0: ID: 300415 POWERLINK V2 MN mode: It was possible that an undefined state occurred during booting that causedthe interface to fail. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 331355 / Support ID: 400092134 POWERLINK V1: If the "Activate Ethernet communication off" option is enabled, asynchronous POWERLINK communication fails in some circumstances. The following configuration may cause asynchronous communication to fail: - POWERLINK V1 - "Activate Ethernet communication off" - POWERLINK CNs on the network that also support POWERLINK V2 This upgrade can be installed to resolve this problem. It is also possible toset "Activate Ethernet communication" to "On". Channel description changed: No Configuration description changed: No Firmwarechanged: Yes ID: 337465 / Support ID: 400108118 POWERLINK V2 CNmode It was possible that an undefined state occurred during booting that causedthe interface to fail. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(30726), 1\42915a0.epl(120) Version 1.2.1.0: ID: 274800 Support of 'Multiple Asynchronous Send' Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 285960 POWERLINK V2 CN mode: Asynchronous packets lost whenthere is a large asynchronous load with large asynchronous frames. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(29702), 1\42915a0.epl(116) Version 1.2.0.0: ID: 264230 POWERLINK V2: Large fluctuationsof IEEE 1588 Nettime (used for safety logbook entries) during startup. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(29702), 1\42915a0.epl(116) Version 1.1.0.2: ID: 256790 / Support ID: 400057319 POWERLINK: In controlled node mode, the I/O mapping was not applied when the manager was restarted. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 256945 POWERLINK: The net time is not always transferred correctly to the application. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 265770 POWERLINK V2 CN mode: Frequent MN failures result in CPU going into Servicemode. Channel descriptionchanged: No Configuration description changed: No Firmware changed:Yes ID: 265915 POWERLINK V2: If the the Ready-Flag was canceledon the network, the ModuleOK was not cleared. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 265870 Warning 32168 "POWERLINK V2: Invalid frame format" on iCN with "Chaned Station" on the same network Error correction: When an iCN is used in the same POWERLINK network with a "Chained Station", there may bewarnings 32168 in the logger. The reason for this warning is that the sync response frames that are used to measure the timing of the "Chained Station" are not recognized by the iCN. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(28677), 1\42915a0.epl(112) Version 1.0.2.0: ID: 233570 Correction of interchanged LinkOK data points in AS IO mapping Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 234660 New POWERLINK firmware V106 POWERLINK V2 chained stations: Reconnecting failed stations improved. LinkOK Datapoint in Operating Mode 'Ethernet' available. Channel description changed: Yes Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(27140), 1\42915a0.epl(106) Version 1.0.1.0: ID: 229290 POWERLINK V2 chained stations: When stations that have failed are added back into the POWERLINK cycle, active chained stations fail. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(26883), 1\42915a0.epl(105) Version 1.0.0.0: ID: 194235 Supportof X20IF1082-2 Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\42915_0.pci(26114), 1\42915a0.epl(102) |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
1.10.0.0 | * | 02/12/2019 | 979 Ko | EXE | AS4_HW_X20IF1082-2.exe | |
Description |
V4.0 HW Upgrade (X20IF1082-2) Revision information X20IF1082-2 Version 1.10.0.0: ID: 614145 / Support ID: 400286104, 400289594 POWERLINK: Possible failure of already configured CNs if new "chained stations" added during operation Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 644020 Error correction: DNA tree topologies not always started up correctly Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(35852), 1\42915a0.epl(140) Version 1.9.0.0: ID: 636510 POWERLINK-Manager: With frequent failure of CN's, which are operated with the optimization "Chained station" it can be happen that failed CN's were not longer adressed by the manager. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(35340), 1\42915a0.epl(138) Version 1.8.0.0: ID: 591100 Documentation updated Version 1.23 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 597825 Cannot connect hardware module to PLK2 interface of X20IF1082-2 in Ethernetmode in AS Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 603490 / Support ID: 400250890 POWERLINK CNs with configuration "Optimization: Minimal latency": No input data received POWERLINK CNs with configuration "Optimization: Minimal latency" and "Chained station: On" that are not physically present in the network can cause no input data to be received from all CNs with setting "Optimization:Minimal latency". Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(34825), 1\42915a0.epl(136) Version 1.7.0.0: ID: 568865 Support HW-Revision DO Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(34313), 1\42915a0.epl(134) Version 1.6.0.0: ID: 539750 / Support ID: 400204420 POWERLINK V2: no asynchronous frames in mode NMT PRE_OPERATIONAL_1 Because of a timing problem in the firmware it could happen that no asynchronous frames were sent in the mode PRE_OPERATIONAL_1 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(33545), 1\42915a0.epl(131) Version 1.5.0.0: ID: 503425 X20-Compact-S support Channel description changed: No Configuration description changed: No Firmware changed: No ID: 504200 Documentation updated version 1.22 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42915_0.pci(32777), 1\42915a0.epl(128) Version 1.4.0.0: ID: 443850 / Support ID: 400154848 IP packets with multicast addresses not received by the POWERLINK interface Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(32777), 1\42915a0.epl(128) Version 1.3.0.0: ID: 394180 / Support ID: 400135055 Support of Poll Response Chaining on iCN Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 410330 / Support ID: 400141340 POWERLINK: Switch to Basic Ethernet of ICN at fail of MN For POWERLNK ICN a switch to basic ethernet modewas build it, so that aftera fail of the POWERLINK MN the ICN station could communicate by standard ethernet. In the POWERLINK Standard this state change is not described yet. Now this feature hat to be enabled explicitly therefore the standard behavior of ICNconforms to the POWERLINK specification. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 417925 Support Bonding feature Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 424025 / Support ID: 400138730 POWERLINK V2: "Controlled node" mode In networks with heavy SoC jitter, the dropping out of an SoC sometimes caused a permanent freezing of the input data on the controlled node. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 424100 / SupportID: 400150240 POWERLINK V2: "Controlled node" mode After a POWERLINK manager failed, the controlled node sometimes registered with an incorrect NMT status in the ident response. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(32521), 1\42915a0.epl(127) Version 1.2.3.0: ID: 358955 POWERLINK MN mode: If "Multiplexing prescale" >= 9, then the input data of the multiplexed stations that were configured in the last "network cycle" were not transferred in certain configurations. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 359175 / Support ID: 400113446 POWERLINK V2 MN mode: Asynchronous connection losses may occur as a result of high asynchronous loads on the POWERLINK network and high loads on the CPU. This could maintain you to an error 32205 Timeout while writing par. via acyclic channel. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 360195 POWERLINK V1 MN mode Error correction: Cyclic input data and net time toggle between the last tworeceived values when CNs drop out. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 360250 / Support ID: - POWERLINK V1 MN mode: "Nettime SoC" is not increased. Channel description changed: No Configuration description changed: No Firmware changed: Yes Version 1.2.2.0: ID: 300415 POWERLINK V2 MN mode: It was possible that an undefined state occurred during booting that causedthe interface to fail. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 331355 / Support ID: 400092134 POWERLINK V1: If the "Activate Ethernet communication off" option is enabled, asynchronous POWERLINK communication fails in some circumstances. The following configuration may cause asynchronous communication to fail: - POWERLINK V1 - "Activate Ethernet communication off" - POWERLINK CNs on the network that also support POWERLINK V2 This upgrade can be installed to resolve this problem. It is also possible toset "Activate Ethernet communication" to "On". Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 337465 / Support ID: 400108118 POWERLINKV2 CN mode It was possible that an undefined state occurred during booting that causedthe interface to fail. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(30726), 1\42915a0.epl(120) Version 1.2.1.0: ID: 274800 Support of 'Multiple Asynchronous Send' Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 285960 POWERLINK V2 CN mode: Asynchronous packets lost when there is a large asynchronous load with large asynchronous frames. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(29702), 1\42915a0.epl(116) Version 1.2.0.0: ID: 264230 POWERLINK V2: Large fluctuations of IEEE 1588 Nettime (used for safety logbook entries) during startup. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(29702), 1\42915a0.epl(116) Version 1.1.0.2: ID: 256790 / Support ID: 400057319 POWERLINK: In controlled node mode, the I/O mapping was not applied when themanager was restarted. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 256945 POWERLINK: The net time is not always transferred correctly to the application. Channel description changed: No Configuration description changed:No Firmware changed: Yes ID: 265770 POWERLINK V2 CN mode: Frequent MN failures result in CPU going into Servicemode. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 265915 POWERLINK V2: If the the Ready-Flag was canceled on the network, the ModuleOK was not cleared. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 265870 Warning 32168 "POWERLINK V2: Invalid frame format" on iCN with "Chaned Station" on the same network Error correction: Whenan iCN is used in the same POWERLINK network with a "Chained Station", there may be warnings 32168 in the logger. The reason for this warning is that the sync response frames that are used to measure the timing of the "Chained Station" are not recognized by the iCN. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(28677), 1\42915a0.epl(112) Version 1.0.2.0: ID: 233570 Correction of interchanged LinkOK data points in AS IO mapping Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 234660 New POWERLINK firmwareV106 POWERLINK V2 chained stations: Reconnecting failed stations improved. LinkOK Datapoint in Operating Mode 'Ethernet' available. Channel description changed: Yes Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(27140), 1\42915a0.epl(106) Version 1.0.1.0: ID: 229290 POWERLINK V2 chained stations: When stations that have failed are added back into the POWERLINK cycle, active chained stations fail. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(26883), 1\42915a0.epl(105) Version 1.0.0.0: ID: 194235 Support of X20IF1082-2 Channel description changed: Yes Configurationdescription changed: Yes Firmware changed: Yes Firmware: 1\42915_0.pci(26114), 1\42915a0.epl(102) |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
1.9.0.0 | * | 09/04/2019 | 936 Ko | EXE | AS4_HW_X20IF1082-2.exe | |
Description |
V4.0 HW Upgrade (X20IF1082-2) Revision information X20IF1082-2 Version 1.9.0.0: ID: 636510 POWERLINK-Manager: With frequent failure of CN's, which are operated with the optimization "Chained station" it can be happen that failed CN's were not longer adressed by the manager. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(35340), 1\42915a0.epl(138) Version 1.8.0.0: ID: 591100 Documentation updated Version 1.23 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 597825 Cannot connect hardware module to PLK2 interface of X20IF1082-2 in Ethernetmode in AS Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 603490 / Support ID: 400250890 POWERLINK CNs with configuration "Optimization: Minimal latency": No input data received POWERLINK CNs with configuration "Optimization: Minimal latency" and"Chained station: On" that are not physically present in the network can cause no input data to be received from all CNs with setting "Optimization: Minimal latency". Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(34825), 1\42915a0.epl(136) Version 1.7.0.0: ID: 568865 Support HW-Revision DO Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(34313),1\42915a0.epl(134) Version 1.6.0.0: ID: 539750 / Support ID: 400204420 POWERLINK V2: no asynchronous frames in mode NMT PRE_OPERATIONAL_1 Because of a timing problem in the firmware it could happen that no asynchronous frames were sent in the mode PRE_OPERATIONAL_1 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(33545), 1\42915a0.epl(131) Version 1.5.0.0: ID: 503425 X20-Compact-S support Channel description changed: No Configuration description changed: No Firmware changed: No ID: 504200 Documentation updated version 1.22 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42915_0.pci(32777), 1\42915a0.epl(128) Version 1.4.0.0: ID: 443850 / Support ID: 400154848 IPpackets with multicast addresses not received by the POWERLINK interface Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(32777), 1\42915a0.epl(128) Version 1.3.0.0: ID: 394180 / Support ID: 400135055 Support of Poll Response Chaining on iCN Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 410330 / Support ID: 400141340 POWERLINK: Switch to Basic Ethernet of ICN at fail of MN For POWERLNK ICN a switch to basic ethernet mode was build it, so that after a fail of the POWERLINK MN the ICN station could communicate by standard ethernet. In the POWERLINK Standard this state change is not described yet. Now this feature hat to be enabled explicitly therefore the standard behavior of ICN conforms to the POWERLINK specification. Channel description changed: No Configuration description changed: No Firmwarechanged: Yes ID: 417925 Support Bonding feature Channel description changed: No Configuration description changed: No Firmwarechanged: Yes ID: 424025 / Support ID: 400138730 POWERLINK V2: "Controlled node" mode In networks with heavy SoC jitter, the dropping outof an SoC sometimes caused a permanent freezing of the input data on the controlled node. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 424100 / Support ID: 400150240 POWERLINK V2: "Controlled node" mode After a POWERLINK manager failed, the controlled node sometimes registered with an incorrect NMT status in the ident response. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(32521), 1\42915a0.epl(127) Version 1.2.3.0: ID: 358955 POWERLINK MN mode: If "Multiplexing prescale" >= 9, then the inputdata of the multiplexed stations that were configured in the last "network cycle" were not transferred in certain configurations. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 359175 / Support ID: 400113446 POWERLINK V2 MN mode: Asynchronous connection losses may occur as a result of high asynchronous loads on the POWERLINK network and high loads on the CPU. This could maintainyou to an error 32205 Timeout while writing par. via acyclic channel. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 360195 POWERLINK V1 MN mode Errorcorrection: Cyclic input data and net time toggle between the last tworeceived values when CNs drop out. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 360250 / Support ID: - POWERLINK V1 MN mode: "Nettime SoC" is not increased. Channel description changed: No Configuration description changed: No Firmware changed: Yes Version 1.2.2.0: ID: 300415 POWERLINK V2 MN mode: It was possible that an undefined state occurred during booting that causedthe interface to fail. Channel description changed:No Configuration description changed: No Firmware changed: Yes ID: 331355 / Support ID: 400092134 POWERLINK V1: If the "Activate Ethernet communication off" option is enabled, asynchronous POWERLINK communication fails in some circumstances. The following configuration may cause asynchronous communication to fail: - POWERLINK V1 - "Activate Ethernet communication off" - POWERLINK CNs on the network that also support POWERLINK V2 This upgrade can be installed to resolve this problem. It is also possible toset "Activate Ethernet communication" to "On". Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 337465 / Support ID: 400108118 POWERLINK V2 CN mode It was possible that an undefined state occurred during booting thatcaused the interface to fail. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(30726), 1\42915a0.epl(120) Version 1.2.1.0: ID: 274800 Support of 'Multiple Asynchronous Send' Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 285960 POWERLINK V2 CN mode: Asynchronous packets lost when there is a large asynchronous load with large asynchronous frames. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(29702), 1\42915a0.epl(116) Version 1.2.0.0: ID: 264230 POWERLINK V2: Large fluctuations of IEEE 1588 Nettime (used for safety logbook entries) during startup. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(29702), 1\42915a0.epl(116) Version 1.1.0.2: ID: 256790 / Support ID: 400057319 POWERLINK: In controlled node mode, the I/O mapping was not applied when the manager was restarted. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 256945 POWERLINK: The net time is not always transferred correctly to the application. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 265770 POWERLINK V2 CN mode: Frequent MN failures result in CPU going into Servicemode. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 265915 POWERLINK V2: If the the Ready-Flag was canceled on the network, the ModuleOK was not cleared. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 265870 Warning 32168 "POWERLINK V2: Invalid frame format" on iCN with "Chaned Station" on the same network Error correction: When an iCNis used in the same POWERLINK network with a "Chained Station", there may be warnings 32168 in the logger. The reason for this warning is that the sync response frames that are used to measure the timing of the "Chained Station"are not recognized by the iCN. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(28677), 1\42915a0.epl(112) Version 1.0.2.0: ID: 233570 Correction of interchanged LinkOK data points in AS IO mapping Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 234660 New POWERLINK firmware V106 POWERLINK V2 chained stations: Reconnecting failed stations improved. LinkOK Datapoint in Operating Mode 'Ethernet' available. Channel description changed: Yes Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(27140), 1\42915a0.epl(106) Version 1.0.1.0: ID: 229290 POWERLINK V2 chained stations: When stations that have failed are added back into the POWERLINK cycle, active chained stations fail. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(26883), 1\42915a0.epl(105) Version 1.0.0.0: ID: 194235 Support of X20IF1082-2 Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\42915_0.pci(26114), 1\42915a0.epl(102) |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
1.8.0.0 | * | 24/08/2018 | 934 Ko | EXE | AS4_HW_X20IF1082-2.exe | |
Description |
V4.0 HW Upgrade (X20IF1082-2) Revision information X20IF1082-2 Version 1.8.0.0: ID: 591100 Documentation updated Version 1.23 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 597825 Cannot connect hardware module to PLK2 interface of X20IF1082-2 in Ethernetmode in AS Channeldescription changed: No Configuration description changed: Yes Firmware changed: No ID: 603490 / Support ID: 400250890 POWERLINK CNs with configuration "Optimization: Minimal latency": No input data received POWERLINK CNs with configuration "Optimization: Minimal latency" and "Chained station: On" that are not physically present in the network can cause no input data to be received from all CNs with setting "Optimization: Minimal latency". Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(34825), 1\42915a0.epl(136) Version 1.7.0.0: ID: 568865 Support HW-Revision DO Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(34313), 1\42915a0.epl(134) Version 1.6.0.0: ID: 539750 / Support ID: 400204420 POWERLINK V2: no asynchronous frames in mode NMT PRE_OPERATIONAL_1 Because of a timing problem in the firmware it could happen that no asynchronous frames were sent in the mode PRE_OPERATIONAL_1 Channel descriptionchanged: No Configuration description changed: No Firmware changed:Yes Firmware: 1\42915_0.pci(33545), 1\42915a0.epl(131) Version 1.5.0.0: ID: 503425 X20-Compact-S support Channel descriptionchanged: No Configuration description changed: No Firmware changed:No ID: 504200 Documentation updated version 1.22 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42915_0.pci(32777), 1\42915a0.epl(128) Version 1.4.0.0: ID: 443850 / Support ID: 400154848 IP packets with multicast addresses not received by the POWERLINK interface Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(32777), 1\42915a0.epl(128) Version 1.3.0.0: ID: 394180 / Support ID: 400135055 Support of Poll Response Chaining on iCN Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 410330 / Support ID: 400141340 POWERLINK: Switch to Basic Ethernet of ICN atfail of MN For POWERLNK ICN a switch to basic ethernet mode was build it, so that after a fail of the POWERLINK MN the ICN station could communicate by standard ethernet. In the POWERLINK Standard this state change is not described yet. Now this feature hat to be enabled explicitly therefore the standard behavior of ICN conforms to the POWERLINK specification. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 417925 Support Bonding feature Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 424025 / Support ID: 400138730 POWERLINK V2: "Controlled node" mode In networks with heavy SoC jitter, the dropping out of anSoC sometimes caused a permanent freezing of the input data on the controllednode. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 424100 / Support ID: 400150240 POWERLINK V2: "Controlled node" mode After a POWERLINK manager failed, the controlled node sometimes registered with an incorrect NMT status in the ident response. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(32521), 1\42915a0.epl(127) Version 1.2.3.0: ID: 358955 POWERLINK MN mode: If "Multiplexing prescale" >= 9, then the input data of the multiplexed stations that were configured in the last "network cycle" were not transferred in certain configurations. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 359175 / Support ID: 400113446 POWERLINK V2 MN mode: Asynchronous connection losses may occur as a result of high asynchronous loads onthe POWERLINK network and high loads on the CPU. This could maintain you to an error 32205 Timeout while writing par. via acyclic channel. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 360195 POWERLINK V1 MN mode Error correction: Cyclic input data and net time toggle between the last two received values when CNs drop out. Channel description changed: No Configurationdescription changed: No Firmware changed: Yes ID: 360250 / Support ID: - POWERLINK V1 MN mode: "Nettime SoC" is not increased. Channel description changed: No Configuration description changed: No Firmware changed: Yes Version 1.2.2.0: ID: 300415 POWERLINKV2 MN mode: It was possible that an undefined state occurred during booting that causedthe interface to fail. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 331355 / Support ID: 400092134 POWERLINK V1: If the "Activate Ethernetcommunication off" option is enabled, asynchronous POWERLINK communication fails in some circumstances. The following configuration may cause asynchronous communication to fail: - POWERLINK V1 - "Activate Ethernet communication off" - POWERLINK CNs on the network that also support POWERLINK V2 This upgrade can be installed to resolve this problem. It is also possible toset "Activate Ethernet communication" to "On". Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 337465 / Support ID: 400108118 POWERLINK V2 CN mode It was possible that an undefined state occurred during booting that causedthe interface to fail. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(30726), 1\42915a0.epl(120) Version 1.2.1.0: ID: 274800 Support of 'Multiple Asynchronous Send' Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 285960 POWERLINK V2 CN mode: Asynchronous packets lost when there is a large asynchronous load with large asynchronous frames. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(29702), 1\42915a0.epl(116) Version 1.2.0.0: ID: 264230 POWERLINK V2: Large fluctuations of IEEE 1588 Nettime (used for safety logbook entries) during startup. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(29702), 1\42915a0.epl(116) Version 1.1.0.2: ID: 256790 / Support ID: 400057319 POWERLINK: In controlled node mode, the I/O mapping was not applied when the manager was restarted. Channel description changed: No Configuration descriptionchanged: No Firmware changed: Yes ID: 256945 POWERLINK: The net time is not always transferred correctly to the application. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 265770 POWERLINK V2 CN mode: Frequent MN failures result in CPU going into Servicemode. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 265915 POWERLINK V2: If the the Ready-Flag was canceled on thenetwork, the ModuleOK was not cleared. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 265870 Warning 32168 "POWERLINK V2: Invalid frame format" on iCN with"Chaned Station" on the same network Error correction: When an iCN is used in the same POWERLINK network with a "Chained Station", there may be warnings 32168 in the logger. The reason for this warning is that the sync response frames that are used to measure the timing of the "Chained Station" are not recognized by the iCN. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(28677), 1\42915a0.epl(112) Version 1.0.2.0: ID: 233570 Correction of interchanged LinkOK data points in AS IO mapping Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 234660 New POWERLINK firmware V106 POWERLINK V2 chained stations: Reconnecting failed stations improved. LinkOK Datapoint in Operating Mode 'Ethernet' available. Channel description changed: Yes Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(27140), 1\42915a0.epl(106) Version 1.0.1.0: ID: 229290 POWERLINK V2 chained stations: When stations that have failed are added back into the POWERLINK cycle, active chained stations fail. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(26883), 1\42915a0.epl(105) Version 1.0.0.0: ID: 194235 Support of X20IF1082-2 Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\42915_0.pci(26114), 1\42915a0.epl(102) |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
1.7.0.0 | * | 23/01/2018 | 922 Ko | EXE | AS4_HW_X20IF1082-2.exe | |
Description |
V4.0 HW Upgrade (X20IF1082-2) Revision information X20IF1082-2 Version 1.7.0.0: ID: 568865 Support HW-Revision DO Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(34313), 1\42915a0.epl(134) Version 1.6.0.0: ID: 539750 / Support ID: 400204420 POWERLINK V2: no asynchronous frames in mode NMT PRE_OPERATIONAL_1 Because of a timing problem in the firmware it could happen that no asynchronous frames were sent in the mode PRE_OPERATIONAL_1 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(33545), 1\42915a0.epl(131) Version 1.5.0.0: ID: 503425 X20-Compact-S support Channel description changed: No Configuration description changed: No Firmware changed: No ID: 504200 Documentation updated version 1.22 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42915_0.pci(32777), 1\42915a0.epl(128) Version 1.4.0.0: ID: 443850 / Support ID: 400154848 IP packets with multicast addresses not received by the POWERLINK interface Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(32777), 1\42915a0.epl(128) Version 1.3.0.0: ID: 394180 / Support ID: 400135055 Support of Poll Response Chaining on iCN Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 410330 / Support ID: 400141340 POWERLINK: Switch to Basic Ethernet of ICN at fail of MN ForPOWERLNK ICN a switch to basic ethernet mode was build it, so that aftera fail of the POWERLINK MN the ICN station could communicate by standard ethernet.In the POWERLINK Standard this state change is not described yet. Now this feature hat to be enabled explicitly therefore the standard behavior of ICN conforms to the POWERLINK specification. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID:417925 Support Bonding feature Channel description changed: No Configuration description changed: No Firmware changed: Yes ID:424025 / Support ID: 400138730 POWERLINK V2: "Controlled node" mode In networks with heavy SoC jitter, the dropping out of an SoC sometimes caused a permanent freezing of the input data on the controlled node. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 424100 / Support ID: 400150240 POWERLINK V2:"Controlled node" mode After a POWERLINK manager failed, the controlled node sometimes registered with an incorrect NMT status in the ident response. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(32521), 1\42915a0.epl(127) Version 1.2.3.0: ID: 358955 POWERLINK MN mode: If "Multiplexing prescale" >= 9, then the input data of the multiplexed stations that were configured in the last "network cycle" were not transferred in certain configurations. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 359175 / Support ID: 400113446 POWERLINK V2 MN mode: Asynchronous connection losses may occur as a result of high asynchronous loads on the POWERLINK network and high loads on the CPU. This could maintain you to an error 32205 Timeout while writing par. via acyclic channel. Channel description changed:No Configuration description changed: No Firmware changed: Yes ID: 360195 POWERLINK V1 MN mode Error correction: Cyclic input data and net time toggle between the last two received values when CNs drop out. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 360250 / Support ID: - POWERLINK V1 MN mode: "Nettime SoC" is not increased. Channel description changed: No Configuration description changed: No Firmware changed: Yes Version 1.2.2.0: ID: 300415 POWERLINK V2 MN mode: Itwas possible that an undefined state occurred during booting that caused the interface to fail. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 331355 / Support ID: 400092134 POWERLINK V1: If the "Activate Ethernet communication off" option is enabled, asynchronous POWERLINK communication fails in some circumstances. The following configuration may cause asynchronous communication to fail: - POWERLINK V1 - "Activate Ethernet communication off" - POWERLINK CNs on the network that also support POWERLINK V2 This upgrade can be installed to resolve this problem. It is also possible toset "Activate Ethernet communication" to "On". Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 337465 / Support ID: 400108118 POWERLINK V2 CN mode It was possible that an undefined state occurred during booting that causedthe interface to fail. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(30726), 1\42915a0.epl(120) Version 1.2.1.0: ID: 274800 Support of 'Multiple Asynchronous Send' Channel description changed: No Configurationdescription changed: No Firmware changed: Yes ID: 285960 POWERLINK V2 CN mode: Asynchronous packets lost when there is a large asynchronous load with large asynchronous frames. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(29702), 1\42915a0.epl(116) Version 1.2.0.0: ID: 264230 POWERLINK V2: Large fluctuations of IEEE 1588 Nettime (usedfor safety logbook entries) during startup. Channel description changed:No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(29702), 1\42915a0.epl(116) Version 1.1.0.2: ID: 256790 / Support ID: 400057319 POWERLINK: In controlled node mode, the I/O mapping was not applied when the manager was restarted. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 256945 POWERLINK: The net time is not always transferred correctly to the application. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 265770 POWERLINK V2 CN mode: Frequent MN failures result in CPU going into Servicemode. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 265915 POWERLINK V2: If the the Ready-Flag was canceled on the network, the ModuleOK was not cleared. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 265870 Warning 32168 "POWERLINK V2: Invalid frame format" on iCN with "Chaned Station" onthe same network Error correction: When an iCN is used in the same POWERLINK network with a "Chained Station", there may be warnings 32168 in the logger. The reason for this warning is that the sync response frames that areused to measure the timing of the "Chained Station" are not recognized by theiCN. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(28677), 1\42915a0.epl(112) Version 1.0.2.0: ID: 233570 Correction of interchanged LinkOK data points in AS IO mapping Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 234660 New POWERLINK firmware V106 POWERLINK V2 chained stations: Reconnecting failed stations improved. LinkOK Datapoint in Operating Mode 'Ethernet' available. Channel description changed: Yes Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(27140), 1\42915a0.epl(106) Version 1.0.1.0: ID: 229290 POWERLINK V2 chained stations: When stations that have failed are added back into the POWERLINK cycle, active chained stations fail. Channeldescription changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(26883), 1\42915a0.epl(105) Version 1.0.0.0: ID: 194235 Support of X20IF1082-2 Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\42915_0.pci(26114), 1\42915a0.epl(102) |