DWL@DWL10000605941
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
---|---|---|---|---|---|---|
1.7.0.0 | * | 16/07/2019 | 643 Ko | EXE | AS4_HW_5ACCIF01.FPCS-000.exe | |
Description |
V4.0 HW Upgrade (5ACCIF01.FPCS-000) Revision information 5ACCIF01.FPCC-000 Version 1.7.0.0: ID: 647670 POWERLINK: Possible failure of already configured CNs if new "chained stations" added during operation Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 647675 Error correction: DNA tree topologies not always started up correctly Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 647680 POWERLINK-Manager: With frequent failure of CN's, whichare operated with the optimization "Chained station" it can be happen that failed CN's were not longer adressed by the manager. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 647685 Preparation to support the Automation PC 2200 and the Panel PC 2200 Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\59837_0.pci(11), 1\59837a0.epl(140) Version 1.6.0.0: ID: 634855 Bugfix in the FPGA firmware The stability of the communication has been optimized for harsh environment. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\59837_0.pci(11), 1\59837a0.epl(136) Version 1.4.0.0: ID: 622945 Corrupted CAN messages on IF3 and IF4 (CAN) With heavy load on the processor interface a "race condition" may exist on the CAN control for IF3 and IF4 (CAN). As a result, the register access and the data access may interfere. Forsolving this "race condition" a locking mechanism has been added, that allowsdata access to the CAN component only after theconfiguration via register accesses have been finished. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\59837_0.pci(10), 1\59837a0.epl(136) Version 1.3.0.0: ID: 617500 Firmware optimized for stability Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 617505 POWERLINK CNs with configuration "Optimization: Minimal latency": No input data received POWERLINK CNs with configuration "Optimization: Minimal latency" and "Chained station: On" that are not physically present in thenetwork can cause no input data to be received from all CNs with setting "Optimization: Minimal latency". Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 617510 POWERLINK V2: no asynchronous frames in mode NMT PRE_OPERATIONAL_1 Because of a timing problem in the firmware it could happen that no asynchronous frames were sent in the mode PRE_OPERATIONAL_1 Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 617565 Revision of the configuration of RemMem datas in dependency of the ARwin From ARwin version M4.10 or A4.26 on it is possible to configure up to 256kB as remanent datas. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 621555 Firmware correction Bugfix for legacy PCI interrupts. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\59837_0.pci(9), 1\59837a0.epl(136) Version 1.2.0.0: ID: 479805 Revision of the configuration of RemMem datas in dependency of the AR From ARemb version L4.10 or C4.25 on it is possible to configure up to 256kB as remanent datas. With ARwinit is furthermore possible to use 128kB as RemMem data. An increase of the RemMem datas for ARwin is planed for a later version. Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\59837_0.pci(6), 1\59837a0.epl(129) Version 1.1.0.0: ID: 472860 IP packets with multicast addresses not received by POWERLINK interface (problem only occurs with Automation Runtime versions <A4.23) Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 474350 Increase of the RemMem up to 256kB From AR version L4.10 or from AR version C4.25 the configuration up to 256kB remanent datas is possible. Note: This upgrade needs at least the version L4.10 or C4.25! Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\59837_0.pci(6), 1\59837a0.epl(129) Version 1.0.2.0: ID: 470685 New FPGA version V6 nvSRAM bug fix for unaligned memory access. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 470700 Reduced X2X susceptibility to disturbances Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\59837_0.pci(6), 1\59837a0.epl(128) Version 1.0.1.0: ID: 459245 Cycle time for X2X Bus adepted The minmal cycle time for the X2X Bus is 400µs. Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\59837_0.pci(4), 1\59837a0.epl(128) Version 1.0.0.0: ID: 457415 Support for 5ACCIF01.FPCC-000 The 5ACCIF01.FPCC-000 interface card is supported beginningwith Automation Studio 4.1.4.x and Automation Runtime J4.10. The 5ACCIF01.FPCC-000 interface card is supported beginning with Automation Studio 4.2.5.x and Automation Runtime A4.25. Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\59837_0.pci(4), 1\59837a0.epl(128) |