DWL@DWL10000096674
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
---|---|---|---|---|---|---|
1.9.1.0 | * | 17/07/2015 | 3 Mo | EXE | AS3.0_HW_X20SC2432.exe | |
Description |
V3.0 HW Upgrade (X20SC2432) Revision information X20SC2432 Version 1.9.1.0: ID: 425445 change of input filter The behaviour of the input filter has changed. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 425460 Update Online Help Update Online Help V1.91 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 425465 fw valid from SafetyRelease 1.4 on Thefirmware is used for all SafetyReleases from 1.4 on. Channel descriptionchanged: No Configuration description changed: Yes Firmware changed: No Firmware: 2\42916_1.fw(272), 6\42916_1.fw(301) Version 1.9.0.0: ID: 243055 / Support ID: 400054331 DXF-File ready to be downloaded DXF-File ready to be downloaded Channel description changed: No Configuration description changed: No Firmware changed: No ID: 413815 SafeModuleID >300 Now it is possible to set SafeModuleID greater than 300, like described in the AS-Help. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 413920 Channel-Status-Info ON The default value of the Channel-Status information is now ON. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 414320 Update Online Help Update Online Help V1.90 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 2\42916_1.fw(272), 3\42916_1.fw(282), 4\42916_1.fw(290), 5\42916_1.fw(300) Version 1.6.0.8: ID: 388340 The module also supports SafetyRelease 1.8 Starting with this version, the module also supports SafetyRelease 1.8 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 2\42916_1.fw(272), 3\42916_1.fw(282), 4\42916_1.fw(290) Version 1.6.0.7: ID: 339225 internal Adjustments internal Adjustments Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 2\42916_1.fw(272), 3\42916_1.fw(282), 4\42916_1.fw(290) Version 1.6.0.5: ID: 335320 / Support ID:400083263 unlock of SafeModule IDs > 300 SafeModule IDs up to 1023 are now unlocked Channel description changed: No Configuration description changed: No Firmware changed: No ID: 335325 The module also supports SafetyRelease 1.7 Starting with this version, the modulealso supports SafetyRelease 1.7 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 2\42916_1.fw(272), 3\42916_1.fw(282), 4\42916_1.fw(290) Version 1.6.0.0: ID: 314295 Adaption of module configuration file release 1.6 Adaption of module configuration file release 1.6 Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 2\42916_1.fw(272), 3\42916_1.fw(282), 4\42916_1.fw(290) Version 1.5.0.4: ID: 303355 Support of AutomationStudio 4.0 Support of AutomationStudio 4.0 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware:2\42916_1.fw(272), 3\42916_1.fw(282), 4\42916_1.fw(290) Version 1.5.0.3: ID: 287440 New feature Discrepancy time maximum from 500ms to 10s increased. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 290260 Datasheet Version 1.50 Datasheet version 1.50 added in Html format Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 2\42916_1.fw(272), 3\42916_1.fw(282), 4\42916_1.fw(290) Version 1.4.1.3: ID: 284650 Release für kompatibles Safety Release 1.5 ID 284600 Parameter for backwards compatibility in description file changed Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 2\42916_1.fw(272), 3\42916_1.fw(282) Version 1.4.1.1: ID: 272230 Release for Safety Release 1.5 Release for Safety Release 1.5 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 2\42916_1.fw(272), 3\42916_1.fw(282) Version 1.4.0.1: ID: 225435 Safety Release 1.4 - SI: one can configure the channel that shall be used as pulse source for testpulse with mode "internal" (see manual) - different levels for logger entires: "Info", "Warning" or "Error" (AR B3.05 required) - logger entrieswith level "Info" or "Warning" are sent by only 1 of the 2 safety processors to reduce the number of messages - X2X diagnostics data points (AR 3.08 required) Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 2\42916_1.fw(272), 3\42916_1.fw(282) Version 1.2.1.0: ID: 219630 erroneous discrepancy time error message An erroneous discrepancy time error message could be generated at startup by the 2 channel evaluation if external devices areused that generate test pulses. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 2\42916_1.fw(272) Version 1.2.0.3: ID: 213430 changes in HWC fixed typos of safety parameters enabled for AR B2.96 Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 2\42916_1.fw(271) Version 1.2.0.0: ID: 212845 first official release first official release Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 2\42916_1.fw(272), 3\42916_1.fw(282) |