DWL@DWL10000340434
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
---|---|---|---|---|---|---|
1.3.5.0 | * | 12/02/2016 | 2 MB | EXE | AS3.0_HW_X20IF10E3-1.exe | |
Description |
V3.0 HW Upgrade (X20IF10E3-1) Revision information X20IF10E3-1 Version 1.3.5.0: ID: 462355 FDT/DTM Cycle Time change Change parameter name "Cycle time [µs]" to "Data exchange time (CPU-netX) [µs]" Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42782a1.fw(41), 1\42782_1.fw(12) Version 1.3.4.0: ID: 465260 X20IF10E3-1 provides an incorrect Serialnumber or no ModulOK Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42782a1.fw(41), 1\42782_1.fw(12) Version 1.3.2.0: ID: 432450 / Support ID: 400167288 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42782a1.fw(42), 1\42782_1.fw(12) Version 1.3.1.0: ID: 427515 / Support ID: 400152176 Internal error 6999 when creating a project Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\42782a1.fw(38), 1\42782_1.fw(12) Version 1.3.0.3: ID: 382305 Zertifizierung Certification of the Interface card, according Profinet Standard V 2.31. Conformance Class: B,C Netload Class: III Firmware: V 3.5.52 Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 392380 Support coated cpus and buscontroller Support coated cpus and buscontroller Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42782a1.fw(38), 1\42782_1.fw(12) Version 1.2.0.0: ID: 299210 New firmware: PI/PNO certification Channel description changed: No Configurationdescription changed: No Firmware changed: No Firmware: 1\42782a1.fw(26), 1\42782_1.fw(12) Version 1.1.1.0: ID: 267080 Profinet slave sends LLDP packets with management address 0.0.0.0 If a Profinetslave is given a fixed IP address by a Profinet Master, when the slave is restarted it still sends 5 LLDP packets with the management address 0.0.0.0. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42782a1.fw(24), 1\42782_1.fw(12) Version 1.1.0.1: ID: 257465 Vendor ID changed Module identifies with B&R Vendor ID now Caution! This upgrade requires changed settings on the master using the latest GSD file. Channel descriptionchanged: No Configuration description changed: No Firmware changed:Yes Firmware: 1\42782a1.fw(19), 1\42782_1.fw(12) Version 1.0.2.0: ID: 240740 X20 Interface PROFINET RT Slave, Configuration of netX cycle time X20 Interface PROFINET RT Slave, Configuration of netX cycle time. Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\42782a1.fw(17), 1\42782_1.fw(12) Version 1.0.1.1: ID: 237570 Interface module PROFINET RT Device, new online help Interface module PROFINET RT Device, newonline help Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42782a1.fw(17), 1\42782_1.fw(12) Version 1.0.1.0: ID: 235805 Interface modulePROFINET RT Device, first version Interface module PROFINET RT Device, first version Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42782a1.fw(17), 1\42782_1.fw(12) Version 1.0.0.0: ID: 228535 Support X20IF10E3-1 Support X20IF10E3-1, first version Channel description changed:No Configuration description changed: No Firmware changed: No Firmware: 1\42782a1.fw(16), 1\42782_1.fw(12) |