DWL@DWL10000782487
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
---|---|---|---|---|---|---|
1.06 | * | 19/06/2024 | 2 Mo | ZIP | UPG_APC4100_MTCX_V0106_EFI.zip | |
Description |
APC4100 Firmware upgrade (MTCX, SDL4T) ---------------------------------------------------------------- ATTENTION! Possible upgrade problems and version dependency ---------------------------------------------------------------- 1. Do not reset or switch off the device during the upgrade process !!! 2. If a UPS is connected to the system, the battery unit must be disconnected or the Power button must be pressed (to set the system in standby mode) after the upgrade is done, but before the required Power Off/On is done. Otherwise the firmware upgrade is not complete, because the UPS will provide the system with power. 3. A Extended upgrade for the SDL4T Firmware is only necessary if an SDL4T firmware less than V01.00 is installed. 4. Starting with SDL4T Firmware V01.00, a downgrade to a version smaller then V01.00 is not possible. 5. Starting with SDL4T Firmware V01.00, a Automation Panel Firmware update for the SDL4R Firmware at least from V06.14 and HDBT Firmware at least from V01.00 is necessary. ---------------------------------------------------------------- Version 01.06 / 04/23/2024 / MIK !MANDATORY UPDATE! ---------------------------------------------------------------- Content LIESMICH.txt 01.06 NEW README.txt 01.06 NEW STARTUP.nsh 01.03 MTCXAPC4100.nsh 01.03 SDL4TAPC4100.nsh 01.03 MTCXSVC.efi 21.30 11544_0.fw 01.06 NEW 11545_0.fw 01.06 NEW 11546_0.fw 01.06 NEW 11547_0.fw 01.06 NEW 11548_0.fw 01.06 NEW 11933_0.fp (SDL4T) 01.04 Change(s) 11544_0.fw, 11545_0.fw, 11546_0.fw, 11547_0.fw, 11548_0.fw (MTCX Firmware): - Optimized internal power supply. ATTENTION! Possible upgrade problems and version dependency, see above. |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
1.05 | * | 15/04/2024 | 2 Mo | ZIP | UPG_APC4100_MTCX_V0105_EFI.zip | |
Description |
APC4100 Firmware upgrade (MTCX, SDL4T) ---------------------------------------------------------------- ATTENTION! Possible upgrade problems and version dependency ---------------------------------------------------------------- 1. Do not reset or switch off the device during the upgrade process !!! 2. If a UPS is connected to the system, the battery unit must be disconnected or the Power button must be pressed (to set the system in standby mode) after the upgrade is done, but before the required Power Off/On is done. Otherwise the firmware upgrade is not complete, because the UPS will provide the system with power. 3. A Extended upgrade for the SDL4T Firmware is only necessary if an SDL4T firmware less than V01.00 is installed. 4. Starting with SDL4T Firmware V01.00, a downgrade to a version smaller then V01.00 is not possible. 5. Starting with SDL4T Firmware V01.00, a Automation Panel Firmware update for the SDL4R Firmware at least from V06.14 and HDBT Firmware at least from V01.00 is necessary. ---------------------------------------------------------------- Version 01.05 / 01/10/2024 / MIK !MANDATORY UPDATE! ---------------------------------------------------------------- Content LIESMICH.txt 01.05 NEW README.txt 01.05 NEW STARTUP.nsh 01.03 MTCXAPC4100.nsh 01.03 SDL4TAPC4100.nsh 01.03 MTCXSVC.efi 21.30 11544_0.fw 01.05 NEW 11545_0.fw 01.05 NEW 11546_0.fw 01.05 NEW 11547_0.fw 01.05 NEW 11548_0.fw 01.05 NEW 11933_0.fp (SDL4T) 01.04 Change(s) 11544_0.fw, 11545_0.fw, 11546_0.fw, 11547_0.fw, 11548_0.fw (MTCX Firmware): - Optimized internal power supply. - Powerlimitation (Psys) prepared (BIOS required from V01.06). - Support for 5ACCIF04.FPLK-000. - Bugfix: WakeUp from S3 (BIOS required from V01.06). ATTENTION! Possible upgrade problems and version dependency, see above. |