Short description
I/O module | 2 resolver inputs, 2 digital inputs, 2 digital outputs |
General information
B&R ID code | 0xA5C7 |
Status indicators | I/O function per channel, supply voltage, bus function |
Diagnostics | |
Outputs | Yes, using LED status indicator and software |
I/O power supply | Yes, using LED status indicator and software |
Connection type | |
X2X Link | M12, B-coded |
Inputs/Outputs | M12, A-coded |
Encoder | M12, 12-pin, A-coded |
I/O power supply | M8, 4-pin |
Power consumption | |
Internal I/O | 1 W |
X2X Link power supply | 0.75 W |
Additional power dissipation caused by actuators (resistive) [W] | 12.5 W |
Certifications | |
CE | Yes |
UKCA | Yes |
ATEX |
Zone 2, II 3G Ex nA IIA T5 Gc IP67, Ta = 0 - Max. 60°C TÜV 05 ATEX 7201X |
UL |
cULus E115267 Industrial control equipment |
HazLoc |
cCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5 |
KC | Yes |
Resolver inputs
Quantity | 2 |
Reference output | |
Output voltage | Typ. 4.4 Veff |
Output current | Max. 50 mAeff |
Frequency | 10 kHz |
Type | Differential |
Angular position resolution | 14-bit |
Short-circuit protection (reference output) | Yes |
Input impedance | 10.4 kΩ - j*11.1 kΩ |
Resolver type | BRX / BRT |
Resolver transformation ratio | |
BRX | 0.5 (±10%) |
BRT | 1 (±10%) |
I/O power supply
Nominal voltage | 24 VDC |
Voltage range | 18 to 30 VDC |
Digital inputs
Quantity | 2 |
Nominal voltage | 24 VDC |
Input current at 24 VDC | Typ. 5 mA |
Input circuit | Sink |
Input filter | |
Hardware | ≤20 µs |
Software | - |
Sensor power supply | 0.5 A summation current |
Input delay | <1 ms |
Switching threshold | |
Low | <5 V |
High | >15 V |
Digital outputs
Quantity | 2 |
Nominal voltage | 24 VDC |
Nominal output current | 0.5 A |
Total nominal current | 1 A |
Output circuit | Source |
Output protection | Thermal shutdown in the event of overcurrent or short circuit, integrated protection for switching inductive loads, reverse polarity protection of the output power supply |
Switching delay | |
0 → 1 | Max. 500 µs |
1 → 0 | Max. 500 µs |
Switching frequency | |
Resistive load | Max. 100 Hz |
Electrical properties
Electrical isolation |
Channel isolated from bus Channel not isolated from channel
|
Operating conditions
Mounting orientation | |
Any | Yes |
Installation elevation above sea level | |
0 to 2000 m | No limitation |
>2000 m | Reduction of ambient temperature by 0.5°C per 100 m |
Degree of protection per EN 60529 | IP67 |
Ambient conditions
Temperature | |
Operation | -25 to 60°C |
Derating | - |
Storage | -40 to 85°C |
Transport | -40 to 85°C |
Mechanical properties
Dimensions | |
Width | 53 mm |
Height | 85 mm |
Depth | 42 mm |
Weight | 200 g |
Torque for connections | |
M8 | Max. 0.4 Nm |
M12 | Max. 0.6 Nm |
Número de material:
X67DC2322Descripción:
- 2 resolvers
- BRX/BRT evaluation
- 2 digital inputs and outputs for each
The module is equipped with 2 resolver connections as well as 2 digital inputs and outputs for each. It is possible to evaluate BRX and BRT resolvers using a configurable sine gain of 1 or 0.25.
Actualizaciones de hardware de Automation Studio | Versión (fecha) | Descargar |
---|---|---|
AS 2.6 HW Upgrade (X67DC2322) | EXE / 563 KB | |
V3.0 HW Upgrade (X67DC2322) | EXE / 3 MB | |
V4.0 HW Upgrade (X67DC2322) | EXE / 2 MB |
Documentación | Versión (fecha) | Descargar |
---|---|---|
Data sheet X67DC2322 | PDF / 463 KB | |
Installation- / EMC-Guide | PDF / 20 MB | |
X67 System User´s Manual | PDF / 6 MB |
E-CAD (plantillas Electro o EPLAN) | Versión (fecha) | Descargar |
---|---|---|
X67 EPLAN P8 from V2.4 | EXE / 105 MB |
M-CAD (plantillas mecánicas) | Versión (fecha) | Descargar |
---|---|---|
3D File DXF/STEP X67 | ZIP / 4 MB |