Short description
Hub | 8-port industrial hub |
General information
Status indicators | Network activity for each channel, link/collision for each channel, supply voltage |
Diagnostics | |
Bus function | Yes, using LED status indicator |
Hub power supply | Yes, using LED status indicator |
Connection type | |
Fieldbus | 8x M12, D-coded |
I/O power supply | M8, 4-pin |
Power consumption | |
Internal | 2.5 W |
Certifications | |
CE | Yes |
UKCA | Yes |
UL |
cULus E115267 Industrial control equipment |
Interfaces
Type | Ethernet |
Standard (compliance) | ANSI/IEEE 802.3 Class II |
Variant | M12 interface (male connector on the module) |
Line length | Max. 100 m between 2 stations (segment length) |
Transfer rate | 10/100 Mbit/s |
Transfer | |
Physical layer | 10BASE-T/100BASE-TX |
Half-duplex | Yes |
Full-duplex | No |
Autonegotiation | Yes |
Auto-MDI/MDIX | Yes |
Hub propagation delay | 0.79 to 0.86 µs |
I/O power supply
Nominal voltage | 12/24 VDC |
Voltage range | 8 to 32 VDC |
Integrated protection | Reverse polarity protection, overvoltage protection |
Operating conditions
Mounting orientation | |
Any | Yes |
Installation elevation above sea level | |
0 to 2000 m | No limitation |
>2000 m | Reduction of ambient temperature by 0.5°C per 100 m |
Degree of protection per EN 60529 | IP67 |
Ambient conditions
Temperature | |
Operation | -40 to 60°C |
Derating | See section "Derating". |
Storage | -40 to 85°C |
Transport | -40 to 85°C |
Mechanical properties
Dimensions | |
Width | 53 mm |
Height | 155 mm |
Depth | 42 mm |
Weight | 320 g |
Torque for connections | |
M8 | Max. 0.4 Nm |
M12 | Max. 0.6 Nm |
Número de material:
X67HB8880.L12Descripción:
- 8-port industrial hub
- Large voltage range of 8 to 32 VDC
- Load dump protection
The Ethernet hub is a standalone device that can be used universally as a hub in POWERLINK networks. It is suitable for both 100 Mbit/s (Fast Ethernet) and 10 Mbit/s networks. The hub automatically recognizes the transfer speed for the channels.
The Ethernet connections are made using D-keyed M12 connectors. All ports are equipped with auto-MDIX (auto-crossover).
The module is designed for a voltage range of 8 to 32 VDC and equipped with a power supply protected against load dump.
Actualizaciones de hardware de Automation Studio | Versión (fecha) | Descargar |
---|---|---|
V4.0 HW Upgrade (X67HB8880.L12) | EXE / 993 KB |
Certificados | Versión (fecha) | Descargar |
---|---|---|
E115267 UL CoC X67 | PDF / 155 KB | |
EU Declaration ATEX X67 | PDF / 191 KB | |
EU Declaration PLC X67 | PDF / 674 KB | |
UK Declaration PLC X67 | PDF / 469 KB |
Documentación | Versión (fecha) | Descargar |
---|---|---|
Data sheet X67HB8880.L12 | PDF / 262 KB | |
Installation- / EMC-Guide | PDF / 20 MB | |
X67 System User´s Manual | PDF / 6 MB |
E-CAD (plantillas Electro o EPLAN) | Versión (fecha) | Descargar |
---|---|---|
X67 EPLAN P8 from V2.4 | EXE / 105 MB |
M-CAD (plantillas mecánicas) | Versión (fecha) | Descargar |
---|---|---|
3D File DXF/STEP X67HB8880.L12 | ZIP / 69 KB |