Short description
Communication module | 1x X2X Link master |
General information
B&R ID code | 0x2525 |
Status indicators | Module status, data transfer |
Diagnostics | |
Module status | Yes, using LED status indicator |
Data transfer | Yes, using LED status indicator |
Power consumption | 1.29 W |
Additional power dissipation caused by actuators (resistive) [W] | - |
Certifications | |
CE | Yes |
UKCA | Yes |
ATEX |
Zone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user's manual) FTZÚ 09 ATEX 0083X |
UL |
cULus E115267 Industrial control equipment |
HazLoc |
cCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5 |
KC | Yes |
Interfaces
Interface IF1 | |
Fieldbus | X2X Link master |
Variant | 4-pin male multipoint connector |
Number of stations | Max. 253 |
Internal bus power supply | No |
Network topology | Line |
Distance between 2 stations | Max. 100 m |
Bus terminating resistor | Internal |
Electrical properties
Electrical isolation | PLC isolated from X2X Link (IF1) |
Operating conditions
Mounting orientation | |
Horizontal | Yes |
Vertical | Yes |
Installation elevation above sea level | |
0 to 2000 m | No limitation |
>2000 m | Reduction of ambient temperature by 0.5°C per 100 m |
Degree of protection per EN 60529 | IP20 |
Ambient conditions
Temperature | |
Operation | |
Horizontal mounting orientation | -25 to 60°C |
Vertical mounting orientation | -25 to 50°C |
Derating | - |
Storage | -40 to 85°C |
Transport | -40 to 85°C |
Relative humidity | |
Operation | 5 to 95%, non-condensing |
Storage | 5 to 95%, non-condensing |
Transport | 5 to 95%, non-condensing |
Mechanical properties
Note | Order 1x terminal block TB704 separately. |
Slot | In expandable bus controller X20BC1083-1 |
Número de material:
X20IF1091-1Descripción:
- X2X Link connection
The interface module is operated in the X20BC1083 expandable bus controller. It is equipped with an X2X Link master interface.
Accesorios obligatorios
Actualizaciones de hardware de Automation Studio | Versión (fecha) | Descargar |
---|---|---|
V2.6 HW Upgrade (X20IF1091-1) | EXE / 520 KB | |
V2.6 HW Upgrade (X20IF1091-1) | EXE / 1 MB | |
V3.0 HW Upgrade (X20IF1091-1) | EXE / 520 KB | |
V3.0 HW Upgrade (X20IF1091-1) | EXE / 1 MB | |
V4.0 HW Upgrade (X20IF1091-1) | EXE / 1 MB |
Documentación | Versión (fecha) | Descargar |
---|---|---|
Datasheet X20IF1091-1 | PDF / 148 KB | |
Installation- / EMC-Guide | PDF / 20 MB | |
X20 Package leaflet ATEX/CSA | PDF / 2 MB | |
X20 System User´s Manual | PDF / 7 MB |
E-CAD (plantillas Electro o EPLAN) | Versión (fecha) | Descargar |
---|---|---|
X20 EPLAN P8 from V2.4 | EXE / 160 MB |
M-CAD (plantillas mecánicas) | Versión (fecha) | Descargar |
---|---|---|
3D File DXF/STEP X20 Interface module X20IF1091/10A1-1 | ZIP / 26 KB | |
Dimensions PDF X20 Interface Module X20IF1091/10A1-1 | PDF / 4 KB |