General information
B&R ID code | 0x1284 |
Slots for plug-in modules | 4 |
Certifications | |
CE | Yes |
UKCA | Yes |
Functional safety | Yes |
UL |
cULus E225616 Power conversion equipment |
KC | Yes |
Mains connection
DC bus connection
DC bus capacitance | 235 µF |
24 VDC power supply
Motor connection
Motor holding brake connection
Response threshold for open-circuit monitoring | Approx. 385 mA |
Max. output current | 1 A |
Max. number of switching cycles | Unlimited since implemented electronically |
Braking resistor
Peak power output | 3.5 kW |
Continuous power | 130 W |
Limit switch and reference inputs
Quantity | 3 |
Circuit | Sink |
Electrical isolation | |
Input - ACOPOS | Yes |
Input - Input | No |
Input voltage | |
Nominal | 24 VDC |
Maximum | 30 VDC |
Switching threshold | |
Low | <5 V |
High | >15 V |
Input current at nominal voltage | Approx. 4 mA |
Switching delay | Max. 2.0 ms |
Modulation compared to ground potential | Max. ±38 V |
Enable inputs
Trigger inputs
Quantity | 2 |
Circuit | Sink |
Electrical isolation | |
Input - ACOPOS | Yes |
Input - Input | No |
Input voltage | |
Nominal | 24 VDC |
Maximum | 30 VDC |
Switching threshold | |
Low | <5 V |
High | >15 V |
Input current at nominal voltage | Approx. 10 mA |
Switching delay | |
Rising edge | 52 µs ±0.5 µs (digitally filtered) |
Falling edge | 53 µs ±0.5 µs (digitally filtered) |
Modulation compared to ground potential | Max. ±38 V |
Electrical properties
Operating conditions
Ambient conditions
Mechanical properties
Dimensions | |
Width | 70.5 mm |
Height | 375 mm |
Depth | 235.5 mm |
Weight | 4.0 kg |
Número de material:
8V1022.00-2Descripción:
- Modular mechanical design using plug-in modules
- Integrated line filter
- Integrated braking resistor
- All connections are made using plug-in connectors
- Integrated electronic restart inhibit
Incluido en la entrega
Shielding component sets
8X0010.00-1 | ACOPOS shielding components set for 8V1022.xxx-x up to 8V1090.xxx-x |
Terminal sets
8X0001.00-1 | ACOPOS accessories, connector set for 8V1010.00 to 8V1090.00 (3-phase) |
Accesorios opcionales
Plug-in modules
8AC110.60-3 | ACOPOS plug-in module, CAN interface |
8AC114.60-2 | ACOPOS plug-in module, POWERLINK V2 interface |
8AC120.60-1 | ACOPOS plug-in module, EnDat encoder and sine incremental encoder interface |
8AC121.60-1 | ACOPOS plug-in module, HIPERFACE interface |
8AC122.60-3 | ACOPOS plug-in module, resolver interface 10 kHz |
8AC123.60-1 | ACOPOS plug-in module, incremental encoder and SSI absolute encoder interface |
8AC125.60-1 | ACOPOS plug-in module, BiSS/SSI SinCos/SSI interface |
8AC125.60-2 | ACOPOS plug-in module, BiSS encoder interface 5 V, baud rate 6.25 Mbit/s |
8AC125.61-2 | ACOPOS plug-in module, BiSS encoder interface 12 V, baud rate 6.25 Mbit/s |
8AC126.60-1 | ACOPOS plug-in module, EnDat 2.2 encoder interface |
8AC130.60-1 | ACOPOS plug-in module, 8 digital I/O configurable in pairs as 24 V inputs or outputs 400/100 mA, 2 digital outputs 2 A, order terminal block TB712 separately! |
8AC131.60-1 | ACOPOS plug-in module, 2 analog inputs ±10 V, 2 digital I/Os configurable as 24 V input or output 45 mA, order terminal block TB712 separately! |
Actualizaciones de hardware de Automation Studio | Versión (fecha) | Descargar |
---|---|---|
V3.0 HW Upgrade (8V1022.00-2) | EXE / 391 KB | |
V4.0 HW Upgrade (8V1022.00-2) | EXE / 214 KB | |
V6.0 HW Upgrade (8V1022.00-2) | EXE / 563 KB |
Documentación | Versión (fecha) | Descargar |
---|---|---|
ACOPOS User´s Manual | PDF / 49 MB | |
Datasheet 8V1022.00-2 | PDF / 2 MB | |
Safety Guidelines | PDF / 1 MB |
E-CAD (plantillas Electro o EPLAN) | Versión (fecha) | Descargar |
---|---|---|
ACOPOS EPLAN P8 from V2.4 | EXE / 23 MB |
Herramientas/Utilidades/Ejemplos | Versión (fecha) | Descargar |
---|---|---|
Sistema library | ZIP / 336 KB |
M-CAD (plantillas mecánicas) | Versión (fecha) | Descargar |
---|---|---|
3D file STEP ACOPOS 1022/1045/1090 | ZIP / 2 MB |