General information
Certifications | |
CE | Yes |
UKCA | Yes |
UL |
cULus E115267 Industrial control equipment |
HazLoc |
cULus HazLoc E180196 Industrial control equipment for hazardous locations Class I, Division 2, Groups ABCD, T4 |
Cable construction
Connector
Type | 2x RJ45, male |
Mating cycles | Min. 750 |
Contacts | 8 |
Electrical properties
Operating voltage | ≤100 V |
Conductor resistance | ≤290 Ω/km |
Wave impedance | 100 ±5 Ω (at 100 MHz) |
Transfer properties | Category 6A / Class EA up to 500 MHz per ISO/IEC 11801 (EN 50173-1), ISO/IEC 24702 (EN 50173-3) |
Insulation resistance | ≥500 MΩ/km |
Operating conditions
Pollution degree per EN 61131-2 | Pollution degree 2 |
Flame-retardant | IEC 60332-1-2 |
Oil and hydrolysis resistance | EN 60811-2-1 (90°C / 7x24 h) |
Degree of protection per EN 60529 | |
Cables | IP20 |
RJ45 connector | IP20, only when properly connected |
Ambient conditions
Temperature | |
Storage | -40 to 80°C |
Fixed installation | -40 to 80°C |
Flexible installation | -40 to 80°C |
Mechanical properties
Dimensions | |
Length | 3 m |
Diameter | 6.7 mm |
Bend radius | |
Fixed installation | ≥5x diameter |
Flexible installation | ≥10x diameter |
Weight | 162 g |
Tension | |
In operation | ≤70 N |
During installation | ≤70 N |
Material number:
5CASD3.0030-00Description:
5CASD3.xxxx-00 SDL3/SDL4 cables are designed to transfer SDL3/SDL4 data and enable easy cable installation. Due to the RJ45 connector, the cable is also suitable for narrow feed-throughs, e.g. in swing arm shafts.
Documentation | Version (Date) | Download |
---|---|---|
Automation Panel 9x3 User's Manual | PDF / 10 MB | |
HMI cable manual | PDF / 3 MB |