Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
---|---|---|---|---|---|---|
2.15.0.0 | * | 13.10.2022 | 4 MB | EXE | AS4_HW_X67BC81RT.L12.exe | |
Popis |
V4.1 HW Upgrade (X67BC81RT.L12) Revision information X67BC81RT.L12 Version 2.15.0.0: ID: 758820 Optimization of asynchronous register access Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58076_1.fw(433), 1\58076_2.fw(433), 1\58079_2.fw(440), 1\58079_3.fw(440), 1\58079_4.fw(440) Version 2.14.0.0: ID: 737300 NUMBER:JACK improved ISN (TCP start sequence) generation in IP stack Channel description changed: No Configuration description changed: No Firmware changed: Yes ID:737305 POWERLINK Security Vulnerability (CVE-2020-13987 & CVE-2020-17438) POWERLINK Security Vulnerability (CVE-2020-13987) The POWERLINK IP stack was affected by a security vulnerability impacting thechecksum calculation of TCP/UDP packets. POWERLINK Security Vulnerability (CVE-2020-17438) The POWERLINK IP stack was affected by a security vulnerability impactingfragmented packet reassembly. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 739445 Module documentation revised Data sheet V2.42 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58076_1.fw(432), 1\58076_2.fw(432), 1\58079_2.fw(440), 1\58079_3.fw(440), 1\58079_4.fw(440) Version 2.11.1.0: ID: 697845 Support for automatic DNA configuration from AS 4.9.1 Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\58076_1.fw(430), 1\58076_2.fw(430), 1\58079_2.fw(440), 1\58079_3.fw(440), 1\58079_4.fw(440) Version 2.11.0.0: ID: 602680 / Support ID: 400253593 Accessing non-cyclic registers withAsIOAcc while ModuleOk = FALSE prevents module from starting/communicating Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 664410 Adaptations for AutomationStudio 4.8 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 664450 DNA: Hub of PLK BC active until first IDENT_REQUEST Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 665790 ModuleOk of IO module FALSE after warm restart even though the module is working as expected Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 665860 Accessing non-cyclic registers with AsIOAcc while ModuleOk = FALSE preventsmodule from starting/communicating Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58076_1.fw(430), 1\58076_2.fw(430), 1\58079_2.fw(440), 1\58079_3.fw(440), 1\58079_4.fw(440) Version 2.10.0.0: ID: 634105 / Support ID: 400279757 Status reply of rtiABRPos revised The status reply was extended to detect the loss of the reference impulse signal. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 644050 / Support ID: 400284819 Adaption of internal module communication for large payloads In certain cases, an internal communication problem could occur if large payloads (RES,PAR) were transmitted. The problem was identified and fixed. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 647965 Optimization of the firmware update process Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58076_1.fw(428), 1\58076_2.fw(428), 1\58079_2.fw(440), 1\58079_3.fw(440), 1\58079_4.fw(440) Version 2.9.3.0: ID:639715 / Support ID: 400268096 Alignment of AS output according to the FieldBusDesigner Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\58076_1.fw(427),1\58079_2.fw(430), 1\58079_3.fw(430), 1\58079_4.fw(430) Version 2.9.0.0: ID: 625160 Optimization of hub behavior Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629035 Ring redundancy: Cannot address the CN that closes the ring Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629115 DNA: BC as head-end station switching hub off again Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629190 Shortened preamble of Ethernet frame leading to incorrectlydetected CRC errors Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58076_1.fw(427), 1\58079_2.fw(430), 1\58079_3.fw(430), 1\58079_4.fw(430) Version 2.8.0.0: ID: 619225 / Support ID: 400257683 DNA: PLK hub forwarding for the next node not enabled in rare cases Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 619255 / Support ID: 400262159 Outputs of I/O modules behind the bus coupler not working in some cases if poll-response chaining active Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 621715 / Support ID: 400264883 Display of further diagnostic data points in the I / O mapping of the X2X interface from the X67 bus controller Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\58076_1.fw(426), 1\58079_2.fw(430), 1\58079_3.fw(430), 1\58079_4.fw(430) Version 2.6.0.0: ID: 543990 / Support ID: 400223930 PLK BC not including X2X modules correctly after X2X configuration change Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 570545 / Support ID: 400234859 PLK BC not including X2X modules correctly after X2X configuration change Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 590155 Correction of the functionality of the timestamp outputs Behavour of the timestamp Bit0 flags of CntTs and LatchTs outputs corrected Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 591985 Module documentation revised Data sheet V 1.37 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58076_1.fw(425), 1\58079_2.fw(430), 1\58079_3.fw(430), 1\58079_4.fw(430) Version 2.5.6.0: ID: 548865 Module documentation revised Data sheet V1.36 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 551165 Startup time optimizations Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58076_1.fw(421), 1\58079_3.fw(410), 1\58079_4.fw(410) Version 2.5.4.0: ID: 540340 / Support ID: 400202320 BC sporadically not going into Operational due to X2X-bus problems at startup Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58076_1.fw(419), 1\58079_3.fw(410), 1\58079_4.fw(410) Version 2.5.3.0: ID: 523580 / Support ID: 400205694 safety modulesnot switching to operational state SDO streaming connection via UDP is not always established when PLC and SafeLogic are booted together. Channeldescription changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58076_1.fw(417), 1\58079_3.fw(410), 1\58079_4.fw(410) Version 2.5.2.0: ID: 493915 / Support ID: 400103115,400101850, 400154063, 400190752 First POWERLINK UDP ASnd SDO transfert after long time takes up to 5s. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58076_1.fw(415), 1\58079_3.fw(410), 1\58079_4.fw(410) Version 2.5.1.0: ID: 462450 / Support ID: 400174514 Execution of functionblocks rtiPWM und rtiDiv revised. The functions blocks rtiPWM and rtiDiv do not cause a timing error, when they are used as first instruction in the in reACTIONtask. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 471680 Harmonization of all reACTION modules Harmonization of hardwarefiles for similar usage andeasier maintenance. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 478575 Module documentation revised Data sheet V1.20 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58076_1.fw(413), 1\58079_3.fw(410), 1\58079_4.fw(410) Version 2.5.0.1: ID: 477320 Extension for AS 4.2.5 Description file adapted for usage in Automation Studio 4.2.5 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58076_1.fw(413), 1\58079_3.fw(310), 1\58079_4.fw(310) Version 2.5.0.0: ID: 468160 optimization of X2X FW updates Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468165 / Support ID: 400177243 X2XFW update of several X2X modules is not working Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468170 / Support ID: 400178654 Safety modules in connection with PLK BCs, with only input datapoints, are not initialized.by SL Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468565 CiR support Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\58076_1.fw(413), 1\58079_3.fw(310), 1\58079_4.fw(310) Version 1.2.1.0: ID: 463205 hwx adaption Channel description changed: Yes Configuration description changed: No Firmwarechanged: No Firmware: 1\58076_1.fw(411), 1\58079_3.fw(310), 1\58079_4.fw(310) Version 1.2.0.0: ID: 460130 / Support ID: 400168329 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 460250 / Support ID: 400150525 Error 114834 "Fehler interner SLX-Kommandokanal" bei CPU PowerCycle wenn SLX hinter BC Channel description changed:No Configuration description changed: No Firmware changed: Yes Firmware: 1\58076_1.fw(411), 1\58079_3.fw(310), 1\58079_4.fw(310) Version 1.1.0.0: ID: 439125 / Support ID: 400150496 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 439230 / Support ID: 400128436 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel descriptionchanged: No Configuration description changed: No Firmware changed:Yes ID: 460130 / Support ID: 400168329 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration descriptionchanged: No Firmware changed: Yes ID: 460250 / Support ID: 400150525 Error 114834 "Fehler interner SLX-Kommandokanal" bei CPU PowerCyclewenn SLXhinter BC Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58076_1.fw(411), 1\58079_3.fw(310), 1\58079_4.fw(310) Version 1.0.3.0: ID:432475 hwx-file changes, documentation correction Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\58076_1.fw(300), 1\58079_3.fw(300), 1\58079_4.fw(300) Version 1.0.2.0: ID: 395195 Support X67BC81RT.L12 Support for AutomationStudio incl. documentation (English + German) Channel description changed: No Configuration description changed: No Firmware changed: No ID: 424950 Firmware update extended firmware files for hardware variant 4 added Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58076_1.fw(300), 1\58079_3.fw(300), 1\58079_4.fw(300) Version 1.0.1.0: ID: 400650 Status byte added Status reply for power supply added Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\58076_1.fw(300), 1\58079_2.fw(200), 1\58079_3.fw(200) Version 1.0.0.1: ID: 393325 Support X67BC81RT.L12 Support for AutomationStudio incl. documentation Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58076_1.fw(300), 1\58079_2.fw(200), 1\58079_3.fw(200) Version 1.0.0.0: ID: 357925 Support X67BC81RT.L12 Support for Automation Studio Channel descriptionchanged: No Configuration description changed: No Firmware changed:No Firmware: 1\58076_1.fw(210), 1\58079_2.fw(105), 1\58079_3.fw(105) |
|||||
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
2.14.0.0 | * | 25.10.2021 | 4 MB | EXE | AS4_HW_X67BC81RT.L12.exe | |
Popis |
V4.1 HW Upgrade (X67BC81RT.L12) Revision information X67BC81RT.L12 Version 2.14.0.0: ID: 737300 NUMBER:JACK improved ISN (TCP start sequence) generation in IP stack Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 737305 POWERLINK Security Vulnerability (CVE-2020-13987 & CVE-2020-17438) POWERLINK Security Vulnerability (CVE-2020-13987) The POWERLINKIP stack was affected by a security vulnerability impacting the checksum calculation of TCP/UDP packets. POWERLINK Security Vulnerability (CVE-2020-17438) The POWERLINK IP stack was affected by a security vulnerability impacting fragmented packet reassembly. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 739445 Module documentation revised Data sheet V2.42 Channel description changed: No Configuration description changed: No Firmwarechanged: No Firmware: 1\58076_1.fw(432), 1\58076_2.fw(432), 1\58079_2.fw(440), 1\58079_3.fw(440), 1\58079_4.fw(440) Version 2.11.1.0: ID: 697845 Support for automatic DNA configuration from AS 4.9.1 Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\58076_1.fw(430), 1\58076_2.fw(430), 1\58079_2.fw(440), 1\58079_3.fw(440), 1\58079_4.fw(440) Version 2.11.0.0: ID: 602680 / Support ID: 400253593 Accessing non-cyclic registerswith AsIOAcc while ModuleOk = FALSE prevents module from starting/communicating Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 664410 Adaptations for Automation Studio 4.8 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 664450 DNA: Hubof PLK BC active until first IDENT_REQUEST Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 665790 ModuleOk of IO module FALSE after warm restart even thoughthe module is working as expected Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 665860 Accessing non-cyclic registers with AsIOAcc while ModuleOk = FALSE preventsmodule from starting/communicating Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58076_1.fw(430), 1\58076_2.fw(430), 1\58079_2.fw(440), 1\58079_3.fw(440), 1\58079_4.fw(440) Version 2.10.0.0: ID: 634105 / Support ID: 400279757 Status reply of rtiABRPos revised The status reply was extended to detect the loss of the reference impulse signal. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 644050 / Support ID: 400284819 Adaption of internal module communication for large payloads In certain cases, an internal communication problem could occur if large payloads (RES,PAR) were transmitted. The problem was identified and fixed. Channel description changed:No Configuration description changed: No Firmware changed: Yes ID: 647965 Optimization of the firmware update process Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58076_1.fw(428), 1\58076_2.fw(428), 1\58079_2.fw(440), 1\58079_3.fw(440), 1\58079_4.fw(440) Version 2.9.3.0: ID: 639715 / Support ID: 400268096 Alignment of AS output according to the FieldBusDesigner Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\58076_1.fw(427), 1\58079_2.fw(430), 1\58079_3.fw(430), 1\58079_4.fw(430) Version 2.9.0.0: ID: 625160 Optimization of hub behavior Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629035 Ring redundancy: Cannot address the CN that closes the ring Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629115 DNA:BC as head-end station switching hub off again Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629190 Shortened preamble of Ethernet frame leading to incorrectly detected CRC errors Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58076_1.fw(427), 1\58079_2.fw(430), 1\58079_3.fw(430), 1\58079_4.fw(430) Version 2.8.0.0: ID: 619225 / Support ID: 400257683 DNA: PLK hub forwarding for the next node not enabled in rare cases Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 619255 / Support ID: 400262159 Outputs of I/O modules behind the bus coupler not working in some cases if poll-response chaining active Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 621715 / Support ID: 400264883 Display of further diagnostic data points in the I / O mapping of the X2X interface from the X67 bus controller Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware:1\58076_1.fw(426), 1\58079_2.fw(430), 1\58079_3.fw(430), 1\58079_4.fw(430) Version 2.6.0.0: ID: 543990 / Support ID: 400223930 PLK BC not including X2X modules correctly after X2X configuration change Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 570545 / Support ID: 400234859 PLK BC not including X2X modules correctly after X2X configuration change Channel description changed: No Configuration description changed: No Firmwarechanged: Yes ID: 590155 Correction of the functionality of the timestamp outputs Behavour of the timestamp Bit0 flags of CntTs and LatchTs outputs corrected Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 591985 Module documentation revised Data sheet V 1.37 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58076_1.fw(425), 1\58079_2.fw(430), 1\58079_3.fw(430), 1\58079_4.fw(430) Version 2.5.6.0: ID: 548865 Module documentation revised Data sheet V1.36 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 551165 Startup time optimizations Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware:1\58076_1.fw(421), 1\58079_3.fw(410), 1\58079_4.fw(410) Version 2.5.4.0: ID: 540340 / Support ID: 400202320 BC sporadically not going into Operational due to X2X-bus problems at startup Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58076_1.fw(419), 1\58079_3.fw(410), 1\58079_4.fw(410) Version 2.5.3.0: ID: 523580 / Support ID: 400205694 safety modules not switching to operational state SDO streaming connection via UDPis not always established when PLC and SafeLogic are booted together. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58076_1.fw(417), 1\58079_3.fw(410), 1\58079_4.fw(410) Version 2.5.2.0: ID: 493915 / Support ID: 400103115, 400101850, 400154063, 400190752 First POWERLINK UDP ASnd SDO transfert after long time takes up to 5s. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58076_1.fw(415), 1\58079_3.fw(410), 1\58079_4.fw(410) Version 2.5.1.0: ID: 462450 / Support ID: 400174514 Execution of functionblocks rtiPWM und rtiDiv revised. The functions blocks rtiPWM and rtiDiv do not cause a timing error, when they are used as first instruction in the in reACTION task. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 471680 Harmonization of all reACTION modules Harmonization of hardwarefiles for similar usage and easier maintenance. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 478575 Module documentation revised Data sheet V1.20 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58076_1.fw(413), 1\58079_3.fw(410), 1\58079_4.fw(410) Version 2.5.0.1: ID: 477320 Extension for AS 4.2.5 Description file adapted for usage in Automation Studio 4.2.5 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58076_1.fw(413), 1\58079_3.fw(310), 1\58079_4.fw(310) Version 2.5.0.0: ID: 468160 optimization of X2X FW updates Channel description changed: No Configuration description changed:No Firmware changed: Yes ID: 468165 / Support ID: 400177243 X2X FW update of several X2X modules is not working Channel descriptionchanged: No Configuration description changed: No Firmware changed:Yes ID: 468170 / Support ID: 400178654 Safety modules in connection with PLK BCs, with only input datapoints, are not initialized.by SL Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468565 CiR support Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\58076_1.fw(413), 1\58079_3.fw(310), 1\58079_4.fw(310) Version 1.2.1.0: ID: 463205 hwx adaption Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\58076_1.fw(411), 1\58079_3.fw(310), 1\58079_4.fw(310) Version 1.2.0.0: ID: 460130 / Support ID: 400168329 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 460250 / Support ID: 400150525 Error 114834 "Fehler interner SLX-Kommandokanal" bei CPU PowerCycle wenn SLX hinter BC Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58076_1.fw(411), 1\58079_3.fw(310), 1\58079_4.fw(310) Version 1.1.0.0: ID: 439125 / Support ID: 400150496 I/O modulesbehind POWERLINK bus controllers no longer achieving Operationalmode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 439230 / Support ID: 400128436 I/O modules behind POWERLINK bus controllers no longerachieving Operationalmode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 460130 / Support ID: 400168329 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 460250 / Support ID:400150525 Error 114834 "Fehler interner SLX-Kommandokanal" bei CPU PowerCycle wenn SLX hinter BC Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58076_1.fw(411), 1\58079_3.fw(310), 1\58079_4.fw(310) Version 1.0.3.0: ID: 432475 hwx-file changes, documentation correction Channel description changed: Yes Configuration description changed: Yes Firmwarechanged: No Firmware: 1\58076_1.fw(300), 1\58079_3.fw(300), 1\58079_4.fw(300) Version 1.0.2.0: ID: 395195 Support X67BC81RT.L12 Support for AutomationStudio incl. documentation (English + German) Channel description changed: No Configuration description changed: No Firmware changed: No ID: 424950 Firmware update extended firmware files for hardware variant 4 added Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58076_1.fw(300), 1\58079_3.fw(300), 1\58079_4.fw(300) Version 1.0.1.0: ID: 400650 Status byte added Status reply for power supply added Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\58076_1.fw(300), 1\58079_2.fw(200), 1\58079_3.fw(200) Version 1.0.0.1: ID: 393325 Support X67BC81RT.L12 Support for AutomationStudio incl. documentation Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58076_1.fw(300), 1\58079_2.fw(200), 1\58079_3.fw(200) Version 1.0.0.0: ID: 357925 Support X67BC81RT.L12 Support for Automation Studio Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58076_1.fw(210), 1\58079_2.fw(105), 1\58079_3.fw(105) |
|||||
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
2.11.1.0 | * | 24.08.2020 | 4 MB | EXE | AS4_HW_X67BC81RT.L12.exe | |
Popis |
V4.1 HW Upgrade (X67BC81RT.L12) Revision information X67BC81RT.L12 Version 2.11.1.0: ID: 697845 Support for automatic DNA configuration from AS 4.9.1 Channel description changed: No Configurationdescription changed: Yes Firmware changed: No Firmware: 1\58076_1.fw(430), 1\58076_2.fw(430), 1\58079_2.fw(440), 1\58079_3.fw(440), 1\58079_4.fw(440) Version 2.11.0.0: ID: 602680 / Support ID: 400253593 Accessing non-cyclic registers with AsIOAcc while ModuleOk = FALSE preventsmodule from starting/communicating Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 664410 Adaptations for Automation Studio 4.8 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 664450 DNA: Hub of PLK BC active until first IDENT_REQUEST Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 665790 ModuleOk of IO module FALSEafter warm restart even though the module is working as expected Channeldescription changed: No Configuration description changed: No Firmware changed: Yes ID: 665860 Accessing non-cyclic registers with AsIOAcc while ModuleOk = FALSE preventsmodule from starting/communicating Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58076_1.fw(430), 1\58076_2.fw(430),1\58079_2.fw(440), 1\58079_3.fw(440), 1\58079_4.fw(440) Version 2.10.0.0: ID: 634105 / Support ID: 400279757 Status reply of rtiABRPosrevised The status reply was extended to detect the loss of the reference impulse signal. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 644050 / Support ID: 400284819 Adaption of internal module communication for large payloads In certain cases, an internal communication problem could occur if largepayloads (RES,PAR) were transmitted. The problem was identified and fixed. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 647965 Optimization of the firmware update process Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58076_1.fw(428), 1\58076_2.fw(428), 1\58079_2.fw(440), 1\58079_3.fw(440), 1\58079_4.fw(440) Version 2.9.3.0: ID: 639715 / Support ID: 400268096 Alignment of AS output according to the FieldBusDesigner Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\58076_1.fw(427), 1\58079_2.fw(430), 1\58079_3.fw(430), 1\58079_4.fw(430) Version 2.9.0.0: ID: 625160 Optimization of hub behavior Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629035 Ring redundancy: Cannot address the CN that closes the ring Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629115 DNA: BC as head-end station switching hub off again Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629190 Shortened preamble of Ethernet frame leading to incorrectly detected CRC errors Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58076_1.fw(427), 1\58079_2.fw(430), 1\58079_3.fw(430), 1\58079_4.fw(430) Version 2.8.0.0: ID: 619225 / Support ID: 400257683 DNA: PLK hub forwarding for the next node not enabled in rare cases Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 619255 / Support ID: 400262159 Outputs of I/O modules behind the bus coupler not working in some cases if poll-response chaining active Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 621715 / Support ID: 400264883 Display of further diagnostic data points in the I / O mapping of the X2X interface from the X67 bus controller Channeldescription changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\58076_1.fw(426), 1\58079_2.fw(430), 1\58079_3.fw(430), 1\58079_4.fw(430) Version 2.6.0.0: ID: 543990 / Support ID: 400223930 PLK BC not including X2X modules correctly after X2X configuration change Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 570545 / SupportID: 400234859 PLK BC not including X2X modules correctly after X2X configuration change Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 590155 Correction of the functionality of the timestamp outputs Behavour of the timestamp Bit0 flags of CntTs and LatchTs outputs corrected Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 591985 Module documentation revised Data sheet V 1.37 Channel description changed: No Configuration description changed:No Firmware changed: No Firmware: 1\58076_1.fw(425), 1\58079_2.fw(430), 1\58079_3.fw(430), 1\58079_4.fw(430) Version 2.5.6.0: ID:548865 Module documentation revised Data sheet V1.36 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 551165 Startup time optimizations Channeldescription changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58076_1.fw(421), 1\58079_3.fw(410), 1\58079_4.fw(410) Version 2.5.4.0: ID: 540340 / Support ID: 400202320 BC sporadically not going into Operational due to X2X-bus problems at startup Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58076_1.fw(419), 1\58079_3.fw(410), 1\58079_4.fw(410) Version 2.5.3.0: ID: 523580 / Support ID: 400205694 safety modules not switching to operational state SDO streaming connection via UDP is not always established when PLC and SafeLogic are booted together. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58076_1.fw(417), 1\58079_3.fw(410), 1\58079_4.fw(410) Version 2.5.2.0: ID: 493915 / Support ID: 400103115, 400101850, 400154063, 400190752 First POWERLINK UDP ASnd SDO transfert after long time takes up to 5s. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58076_1.fw(415), 1\58079_3.fw(410), 1\58079_4.fw(410) Version 2.5.1.0: ID: 462450 / Support ID: 400174514 Execution of functionblocks rtiPWM und rtiDiv revised. The functions blocks rtiPWM and rtiDiv do not cause a timing error, when they are used as first instruction in the in reACTION task. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 471680 Harmonization of all reACTION modules Harmonization ofhardwarefiles for similar usage and easier maintenance. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 478575 Module documentation revised Data sheet V1.20 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58076_1.fw(413), 1\58079_3.fw(410), 1\58079_4.fw(410) Version 2.5.0.1: ID: 477320 Extension for AS 4.2.5 Description file adapted for usage in Automation Studio 4.2.5 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58076_1.fw(413), 1\58079_3.fw(310), 1\58079_4.fw(310) Version 2.5.0.0: ID: 468160 optimization of X2X FW updates Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468165 / Support ID: 400177243 X2X FW update of several X2X modules is not working Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468170 / Support ID: 400178654 Safety modules in connection with PLK BCs, with only input datapoints, are not initialized.by SL Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468565 CiR support Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\58076_1.fw(413), 1\58079_3.fw(310), 1\58079_4.fw(310) Version 1.2.1.0: ID: 463205 hwx adaption Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\58076_1.fw(411), 1\58079_3.fw(310), 1\58079_4.fw(310) Version 1.2.0.0: ID:460130 / Support ID: 400168329 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 460250 / Support ID: 400150525 Error 114834 "Fehler interner SLX-Kommandokanal" bei CPU PowerCycle wenn SLX hinter BC Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58076_1.fw(411), 1\58079_3.fw(310), 1\58079_4.fw(310) Version 1.1.0.0: ID: 439125 / SupportID: 400150496 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 439230 / Support ID: 400128436 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 460130 / Support ID: 400168329 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 460250 / Support ID: 400150525 Error 114834 "Fehler interner SLX-Kommandokanal" bei CPU PowerCycle wenn SLX hinter BC Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58076_1.fw(411), 1\58079_3.fw(310), 1\58079_4.fw(310) Version 1.0.3.0: ID: 432475 hwx-file changes, documentation correction Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\58076_1.fw(300), 1\58079_3.fw(300), 1\58079_4.fw(300) Version 1.0.2.0: ID: 395195 Support X67BC81RT.L12 Support for AutomationStudio incl. documentation (English + German) Channel description changed: No Configuration description changed: No Firmware changed: No ID: 424950 Firmware update extended firmware files for hardware variant 4 added Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58076_1.fw(300), 1\58079_3.fw(300), 1\58079_4.fw(300) Version 1.0.1.0: ID: 400650 Status byteadded Status reply for power supply added Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\58076_1.fw(300), 1\58079_2.fw(200), 1\58079_3.fw(200) Version 1.0.0.1: ID: 393325 Support X67BC81RT.L12 Support for AutomationStudio incl. documentation Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58076_1.fw(300), 1\58079_2.fw(200), 1\58079_3.fw(200) Version 1.0.0.0: ID: 357925 Support X67BC81RT.L12 Support for Automation Studio Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58076_1.fw(210), 1\58079_2.fw(105), 1\58079_3.fw(105) |
|||||
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
2.11.0.0 | * | 20.02.2020 | 4 MB | EXE | AS4_HW_X67BC81RT.L12.exe | |
Popis |
V4.1 HW Upgrade (X67BC81RT.L12) Revision information X67BC81RT.L12 Version 2.11.0.0: ID: 602680 / Support ID: 400253593 Accessing non-cyclic registers with AsIOAcc while ModuleOk = FALSE preventsmodule from starting/communicating Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 664410 Adaptations for Automation Studio 4.8 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 664450 DNA: Hub of PLK BC active until first IDENT_REQUEST Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 665790 ModuleOk of IO module FALSE after warm restart even though the module is working as expected Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 665860 Accessing non-cyclic registers with AsIOAcc while ModuleOk = FALSE preventsmodule from starting/communicating Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58076_1.fw(430), 1\58076_2.fw(430), 1\58079_2.fw(440), 1\58079_3.fw(440), 1\58079_4.fw(440) Version 2.10.0.0: ID: 634105 / Support ID: 400279757 Status reply of rtiABRPos revised The status reply was extended to detect the loss of the reference impulse signal. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 644050 / Support ID: 400284819 Adaption of internal module communication for large payloads Incertain cases, an internal communication problem could occur if large payloads (RES,PAR) were transmitted. The problem was identified and fixed. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 647965 Optimization of the firmware update process Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58076_1.fw(428), 1\58076_2.fw(428), 1\58079_2.fw(440), 1\58079_3.fw(440), 1\58079_4.fw(440) Version 2.9.3.0: ID: 639715 / Support ID: 400268096 Alignment of AS output according to the FieldBusDesigner Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\58076_1.fw(427), 1\58079_2.fw(430), 1\58079_3.fw(430), 1\58079_4.fw(430) Version 2.9.0.0: ID: 625160 Optimization of hub behavior Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629035 Ring redundancy: Cannot address the CN that closes the ring Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629115 DNA: BC as head-end station switching hub off again Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629190 Shortened preamble of Ethernet frame leading to incorrectly detected CRC errors Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58076_1.fw(427), 1\58079_2.fw(430), 1\58079_3.fw(430), 1\58079_4.fw(430) Version 2.8.0.0: ID: 619225 / Support ID: 400257683 DNA: PLK hub forwarding for the next node not enabled in rare cases Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 619255 / Support ID: 400262159 Outputs of I/O modules behind the bus coupler not working in some cases if poll-response chaining active Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 621715 / Support ID: 400264883 Display of further diagnostic data points in the I / Omapping of the X2X interface from the X67 bus controller Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\58076_1.fw(426), 1\58079_2.fw(430), 1\58079_3.fw(430), 1\58079_4.fw(430) Version 2.6.0.0: ID: 543990 / Support ID:400223930 PLK BC not including X2X modules correctly after X2X configuration change Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 570545 / Support ID: 400234859 PLK BC not including X2X modules correctly after X2X configurationchange Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 590155 Correction of the functionality of the timestamp outputs Behavour of the timestamp Bit0 flags of CntTs and LatchTs outputs corrected Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 591985 Module documentation revised Data sheet V 1.37 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58076_1.fw(425), 1\58079_2.fw(430), 1\58079_3.fw(430), 1\58079_4.fw(430) Version 2.5.6.0: ID: 548865 Module documentation revised Data sheet V1.36 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 551165 Startup time optimizations Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58076_1.fw(421), 1\58079_3.fw(410), 1\58079_4.fw(410) Version 2.5.4.0: ID: 540340 / Support ID: 400202320 BC sporadically not going into Operational due to X2X-bus problems at startup Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58076_1.fw(419), 1\58079_3.fw(410),1\58079_4.fw(410) Version 2.5.3.0: ID: 523580 / Support ID: 400205694 safety modules not switching to operational state SDO streaming connection via UDP is not always established when PLC and SafeLogic are booted together. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58076_1.fw(417),1\58079_3.fw(410), 1\58079_4.fw(410) Version 2.5.2.0: ID: 493915 / Support ID: 400103115, 400101850, 400154063, 400190752 First POWERLINK UDP ASnd SDO transfert after long time takes up to 5s. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58076_1.fw(415), 1\58079_3.fw(410), 1\58079_4.fw(410) Version 2.5.1.0: ID: 462450 / Support ID: 400174514 Execution of functionblocks rtiPWM und rtiDiv revised. The functions blocksrtiPWM and rtiDiv do not cause a timing error, when they are used as first instruction in the in reACTION task. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 471680 Harmonization of all reACTION modules Harmonization of hardwarefiles for similar usage and easier maintenance. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 478575 Module documentation revised Data sheet V1.20 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58076_1.fw(413), 1\58079_3.fw(410),1\58079_4.fw(410) Version 2.5.0.1: ID: 477320 Extension for AS 4.2.5 Description file adapted for usage in Automation Studio 4.2.5 Channel description changed: No Configuration description changed:No Firmware changed: No Firmware: 1\58076_1.fw(413), 1\58079_3.fw(310), 1\58079_4.fw(310) Version 2.5.0.0: ID: 468160 optimization of X2X FW updates Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468165 / Support ID: 400177243 X2X FW update of several X2X modules is not working Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468170 / Support ID: 400178654 Safety modules in connection with PLK BCs, with only input datapoints, are not initialized.by SL Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468565 CiR support Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\58076_1.fw(413), 1\58079_3.fw(310), 1\58079_4.fw(310) Version 1.2.1.0: ID: 463205 hwx adaption Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\58076_1.fw(411), 1\58079_3.fw(310), 1\58079_4.fw(310) Version 1.2.0.0: ID: 460130 / Support ID: 400168329 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 460250 / Support ID: 400150525 Error 114834 "Fehler interner SLX-Kommandokanal" bei CPU PowerCycle wenn SLX hinter BC Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58076_1.fw(411), 1\58079_3.fw(310), 1\58079_4.fw(310) Version 1.1.0.0: ID: 439125 / Support ID: 400150496 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 439230 / Support ID: 400128436 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 460130 / Support ID: 400168329 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 460250 / Support ID: 400150525 Error 114834 "Fehler interner SLX-Kommandokanal" bei CPU PowerCycle wenn SLX hinter BC Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58076_1.fw(411), 1\58079_3.fw(310), 1\58079_4.fw(310) Version 1.0.3.0: ID: 432475 hwx-file changes, documentation correction Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\58076_1.fw(300), 1\58079_3.fw(300), 1\58079_4.fw(300) Version 1.0.2.0: ID: 395195 Support X67BC81RT.L12 Support for AutomationStudio incl. documentation (English + German) Channel description changed: No Configuration description changed: No Firmware changed: No ID: 424950 Firmwareupdate extended firmware files for hardware variant 4 added Channeldescription changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58076_1.fw(300), 1\58079_3.fw(300), 1\58079_4.fw(300) Version 1.0.1.0: ID: 400650 Status byte added Status reply for power supply added Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\58076_1.fw(300), 1\58079_2.fw(200), 1\58079_3.fw(200) Version1.0.0.1: ID: 393325 Support X67BC81RT.L12 Support for AutomationStudio incl. documentation Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58076_1.fw(300), 1\58079_2.fw(200), 1\58079_3.fw(200) Version 1.0.0.0: ID: 357925 Support X67BC81RT.L12 Support for Automation Studio Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58076_1.fw(210), 1\58079_2.fw(105), 1\58079_3.fw(105) |
|||||
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
2.10.0.0 | * | 10.07.2019 | 4 MB | EXE | AS4_HW_X67BC81RT.L12.exe | |
Popis |
V4.1 HW Upgrade (X67BC81RT.L12) Revision information X67BC81RT.L12 Version 2.10.0.0: ID: 634105 / Support ID: 400279757 Status reply of rtiABRPos revised The status reply was extended to detect the loss of the reference impulse signal. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 644050 / Support ID: 400284819 Adaption of internal module communication for large payloads In certain cases, an internal communication problem could occur if large payloads (RES,PAR) were transmitted. The problem was identified and fixed. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 647965 Optimization of the firmware update process Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58076_1.fw(428), 1\58076_2.fw(428), 1\58079_2.fw(440), 1\58079_3.fw(440), 1\58079_4.fw(440) Version 2.9.3.0: ID: 639715 / Support ID: 400268096 Alignment of AS output according to the FieldBusDesigner Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\58076_1.fw(427), 1\58079_2.fw(430), 1\58079_3.fw(430), 1\58079_4.fw(430) Version 2.9.0.0: ID: 625160 Optimization of hub behavior Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629035 Ring redundancy: Cannot address the CN that closes the ring Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629115 DNA: BC as head-end station switching hub off again Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629190 Shortened preamble of Ethernet frame leading to incorrectly detected CRC errors Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58076_1.fw(427), 1\58079_2.fw(430),1\58079_3.fw(430), 1\58079_4.fw(430) Version 2.8.0.0: ID: 619225 / Support ID: 400257683 DNA: PLK hub forwarding for the next node notenabled in rare cases Channel description changed: No Configurationdescription changed: No Firmware changed: Yes ID: 619255 / Support ID: 400262159 Outputs of I/O modules behind the bus coupler not working in some cases if poll-response chaining active Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 621715 / Support ID: 400264883 Display of further diagnostic data points in the I / O mapping of the X2X interface from the X67 bus controller Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\58076_1.fw(426), 1\58079_2.fw(430), 1\58079_3.fw(430), 1\58079_4.fw(430) Version 2.6.0.0: ID: 543990 / Support ID: 400223930 PLK BC not including X2X modules correctly after X2X configuration change Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 570545 / Support ID: 400234859 PLK BC not including X2X modules correctly after X2X configuration change Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 590155 Correction of the functionality of the timestamp outputs Behavour of the timestamp Bit0 flags of CntTs and LatchTs outputs corrected Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 591985 Module documentation revised Data sheet V 1.37 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58076_1.fw(425), 1\58079_2.fw(430), 1\58079_3.fw(430), 1\58079_4.fw(430) Version 2.5.6.0: ID: 548865 Module documentation revised Data sheet V1.36 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 551165 Startup time optimizations Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58076_1.fw(421), 1\58079_3.fw(410), 1\58079_4.fw(410) Version 2.5.4.0: ID: 540340 / Support ID: 400202320 BC sporadically not going into Operational due to X2X-bus problems at startup Channel description changed: No Configurationdescription changed: No Firmware changed: Yes Firmware: 1\58076_1.fw(419), 1\58079_3.fw(410), 1\58079_4.fw(410) Version 2.5.3.0: ID: 523580 / Support ID: 400205694 safety modules not switching to operational state SDO streaming connection via UDP is not always established when PLC and SafeLogic are booted together. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58076_1.fw(417), 1\58079_3.fw(410), 1\58079_4.fw(410) Version2.5.2.0: ID: 493915 / Support ID: 400103115, 400101850, 400154063, 400190752 First POWERLINK UDP ASnd SDO transfert after long time takes up to 5s. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58076_1.fw(415), 1\58079_3.fw(410), 1\58079_4.fw(410) Version 2.5.1.0: ID: 462450 / Support ID: 400174514 Execution of functionblocks rtiPWM und rtiDiv revised. The functions blocks rtiPWM and rtiDiv do not cause a timing error, whenthey are used as first instruction in the in reACTION task. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 471680 Harmonization of all reACTION modules Harmonization of hardwarefiles for similar usage and easier maintenance. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 478575 Module documentation revised Data sheet V1.20 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58076_1.fw(413), 1\58079_3.fw(410), 1\58079_4.fw(410) Version 2.5.0.1: ID: 477320 Extension for AS 4.2.5 Description file adapted for usagein Automation Studio 4.2.5 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58076_1.fw(413), 1\58079_3.fw(310), 1\58079_4.fw(310) Version 2.5.0.0: ID: 468160 optimization of X2X FW updates Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468165 / Support ID: 400177243 X2X FW update of several X2X modules is not working Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468170 / Support ID: 400178654 Safety modules in connection with PLK BCs, with only input datapoints, are not initialized.by SL Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468565 CiR support Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\58076_1.fw(413), 1\58079_3.fw(310), 1\58079_4.fw(310) Version 1.2.1.0: ID: 463205 hwx adaption Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\58076_1.fw(411), 1\58079_3.fw(310), 1\58079_4.fw(310) Version 1.2.0.0: ID: 460130 / Support ID: 400168329 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 460250 / Support ID: 400150525 Error 114834 "Fehler interner SLX-Kommandokanal" bei CPU PowerCycle wenn SLX hinter BC Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58076_1.fw(411), 1\58079_3.fw(310), 1\58079_4.fw(310) Version 1.1.0.0: ID: 439125 / Support ID: 400150496 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 439230 / Support ID: 400128436 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 460130/ Support ID: 400168329 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 460250 / Support ID: 400150525 Error 114834 "Fehler interner SLX-Kommandokanal" bei CPU PowerCycle wenn SLX hinter BC Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58076_1.fw(411), 1\58079_3.fw(310), 1\58079_4.fw(310) Version 1.0.3.0: ID: 432475 hwx-file changes, documentation correction Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\58076_1.fw(300), 1\58079_3.fw(300), 1\58079_4.fw(300) Version 1.0.2.0: ID: 395195 Support X67BC81RT.L12 Support for AutomationStudio incl. documentation (English + German) Channel description changed: No Configuration description changed: No Firmware changed: No ID: 424950 Firmware update extended firmware files for hardware variant 4 added Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58076_1.fw(300), 1\58079_3.fw(300), 1\58079_4.fw(300) Version 1.0.1.0: ID: 400650 Status byte added Status reply for power supply added Channeldescription changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\58076_1.fw(300), 1\58079_2.fw(200), 1\58079_3.fw(200) Version 1.0.0.1: ID: 393325 Support X67BC81RT.L12 Support for AutomationStudio incl. documentation Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58076_1.fw(300), 1\58079_2.fw(200), 1\58079_3.fw(200) Version 1.0.0.0: ID: 357925 Support X67BC81RT.L12 Support for Automation Studio Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58076_1.fw(210), 1\58079_2.fw(105), 1\58079_3.fw(105) |
|||||
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
2.9.3.0 | * | 12.04.2019 | 4 MB | EXE | AS4_HW_X67BC81RT.L12.exe | |
Popis |
V4.1 HW Upgrade (X67BC81RT.L12) Revision information X67BC81RT.L12 Version 2.9.3.0: ID: 639715 / Support ID: 400268096 Alignment of AS output according to the FieldBusDesigner Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\58076_1.fw(427), 1\58079_2.fw(430), 1\58079_3.fw(430), 1\58079_4.fw(430) Version 2.9.0.0: ID: 625160 Optimization of hub behavior Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629035 Ring redundancy: Cannot address the CN that closes the ring Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629115 DNA: BC as head-end station switching hub off again Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629190 Shortened preamble of Ethernet frame leading to incorrectly detected CRC errors Channel descriptionchanged: No Configuration description changed: No Firmware changed:Yes Firmware: 1\58076_1.fw(427), 1\58079_2.fw(430), 1\58079_3.fw(430), 1\58079_4.fw(430) Version 2.8.0.0: ID: 619225 / Support ID: 400257683 DNA: PLK hub forwarding for the next node not enabled in rare cases Channel description changed: No Configuration description changed:No Firmware changed: Yes ID: 619255 / Support ID: 400262159 Outputs of I/O modules behind the bus coupler not working in some cases if poll-response chaining active Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 621715 / Support ID: 400264883 Display of further diagnostic data points in the I / O mapping of the X2X interface from the X67 bus controller Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\58076_1.fw(426), 1\58079_2.fw(430), 1\58079_3.fw(430), 1\58079_4.fw(430) Version 2.6.0.0: ID: 543990 / Support ID: 400223930 PLK BC not including X2X modules correctly after X2X configuration change Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 570545 / Support ID: 400234859 PLK BC not including X2X modules correctly after X2X configuration change Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 590155 Correction of the functionality of the timestamp outputs Behavour of the timestamp Bit0 flags of CntTs and LatchTs outputs corrected Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 591985 Module documentation revised Data sheet V 1.37 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58076_1.fw(425), 1\58079_2.fw(430), 1\58079_3.fw(430), 1\58079_4.fw(430) Version 2.5.6.0: ID: 548865 Module documentation revised Data sheet V1.36 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 551165 Startup time optimizations Channel description changed: No Configuration description changed: No Firmwarechanged: Yes Firmware: 1\58076_1.fw(421), 1\58079_3.fw(410), 1\58079_4.fw(410) Version 2.5.4.0: ID: 540340 / Support ID: 400202320 BC sporadically not going into Operational due to X2X-bus problems at startup Channel description changed: No Configuration description changed:No Firmware changed: Yes Firmware: 1\58076_1.fw(419), 1\58079_3.fw(410), 1\58079_4.fw(410) Version 2.5.3.0: ID: 523580 / Support ID: 400205694 safety modules not switching to operational state SDO streaming connection via UDP is not always established when PLC and SafeLogic are booted together. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58076_1.fw(417), 1\58079_3.fw(410), 1\58079_4.fw(410) Version 2.5.2.0: ID: 493915 / Support ID: 400103115, 400101850, 400154063, 400190752 First POWERLINK UDP ASnd SDO transfert after long time takes up to 5s. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58076_1.fw(415), 1\58079_3.fw(410), 1\58079_4.fw(410) Version 2.5.1.0: ID: 462450 / Support ID: 400174514 Execution of functionblocks rtiPWM und rtiDiv revised. The functions blocks rtiPWM and rtiDiv do not cause a timing error, when they are used as first instruction in the in reACTION task. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 471680 Harmonization of all reACTION modules Harmonization of hardwarefiles for similar usage and easier maintenance. Channel descriptionchanged: No Configuration description changed: No Firmware changed:Yes ID: 478575 Module documentation revised Data sheet V1.20 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58076_1.fw(413), 1\58079_3.fw(410), 1\58079_4.fw(410) Version 2.5.0.1: ID: 477320 Extension for AS 4.2.5 Description file adapted for usage in Automation Studio4.2.5 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58076_1.fw(413), 1\58079_3.fw(310), 1\58079_4.fw(310) Version 2.5.0.0: ID: 468160 optimization of X2X FW updates Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468165/ Support ID: 400177243 X2X FW update of several X2X modules is not working Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468170 / Support ID: 400178654 Safety modules in connection with PLK BCs, with only input datapoints, arenot initialized.by SL Channel description changed: No Configurationdescription changed: No Firmware changed: Yes ID: 468565 CiR support Channel description changed: No Configuration descriptionchanged: Yes Firmware changed: No Firmware: 1\58076_1.fw(413), 1\58079_3.fw(310), 1\58079_4.fw(310) Version 1.2.1.0: ID: 463205 hwx adaption Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\58076_1.fw(411), 1\58079_3.fw(310), 1\58079_4.fw(310) Version 1.2.0.0: ID: 460130 / Support ID: 400168329 I/O modules behind POWERLINK bus controllersno longer achieving Operationalmode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 460250 / Support ID: 400150525 Error 114834 "Fehler interner SLX-Kommandokanal" bei CPU PowerCycle wenn SLX hinter BC Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58076_1.fw(411), 1\58079_3.fw(310), 1\58079_4.fw(310) Version 1.1.0.0: ID: 439125 / Support ID: 400150496 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 439230 / Support ID: 400128436 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 460130 / Support ID: 400168329 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 460250 / Support ID: 400150525 Error 114834 "Fehler interner SLX-Kommandokanal" bei CPU PowerCycle wenn SLX hinter BC Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58076_1.fw(411), 1\58079_3.fw(310), 1\58079_4.fw(310) Version 1.0.3.0: ID: 432475 hwx-file changes, documentation correction Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\58076_1.fw(300), 1\58079_3.fw(300), 1\58079_4.fw(300) Version 1.0.2.0: ID: 395195 Support X67BC81RT.L12 Support for AutomationStudio incl. documentation (English + German) Channel description changed: No Configuration description changed: No Firmware changed: No ID: 424950 Firmware update extended firmware files for hardware variant 4 added Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58076_1.fw(300), 1\58079_3.fw(300), 1\58079_4.fw(300) Version 1.0.1.0: ID: 400650 Status byte added Status reply for power supply added Channel description changed:Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\58076_1.fw(300), 1\58079_2.fw(200), 1\58079_3.fw(200) Version 1.0.0.1: ID: 393325 Support X67BC81RT.L12 Support forAutomationStudio incl. documentation Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58076_1.fw(300), 1\58079_2.fw(200), 1\58079_3.fw(200) Version 1.0.0.0: ID: 357925 Support X67BC81RT.L12 Support for Automation Studio Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58076_1.fw(210), 1\58079_2.fw(105), 1\58079_3.fw(105) |
|||||
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
2.9.0.0 | * | 13.03.2019 | 4 MB | EXE | AS4_HW_X67BC81RT.L12.exe | |
Popis |
V4.1 HW Upgrade (X67BC81RT.L12) Revision information X67BC81RT.L12 Version 2.9.0.0: ID: 625160 Optimization of hub behavior Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629035 Ring redundancy: Cannot address the CN that closes the ring Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629115 DNA: BC as head-end station switching hub off again Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629190 Shortened preamble of Ethernet frame leading to incorrectly detected CRC errors Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58076_1.fw(427), 1\58079_2.fw(430), 1\58079_3.fw(430), 1\58079_4.fw(430) Version 2.8.0.0: ID: 619225 / Support ID: 400257683 DNA: PLK hub forwarding for the next node not enabled in rare cases Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 619255 / Support ID: 400262159 Outputs of I/O modules behind the bus coupler not working in some cases if poll-response chaining active Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 621715 / Support ID: 400264883 Display of further diagnostic data points in the I / O mapping of the X2X interface from the X67 bus controller Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\58076_1.fw(426), 1\58079_2.fw(430), 1\58079_3.fw(430), 1\58079_4.fw(430) Version 2.6.0.0: ID: 543990 / Support ID: 400223930 PLK BC not including X2X modules correctly after X2X configuration change Channel description changed: No Configuration description changed:No Firmware changed: Yes ID: 570545 / Support ID: 400234859 PLK BC not including X2X modules correctly after X2X configuration change Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 590155 Correction of the functionality of the timestamp outputs Behavour of the timestamp Bit0 flags of CntTs and LatchTs outputs corrected Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 591985 Module documentation revised Data sheet V 1.37 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58076_1.fw(425), 1\58079_2.fw(430), 1\58079_3.fw(430), 1\58079_4.fw(430) Version 2.5.6.0: ID: 548865 Module documentation revised Data sheet V1.36 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 551165 Startup time optimizations Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58076_1.fw(421), 1\58079_3.fw(410), 1\58079_4.fw(410) Version 2.5.4.0: ID: 540340 / Support ID: 400202320 BC sporadically not going into Operational due to X2X-bus problems at startup Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58076_1.fw(419), 1\58079_3.fw(410), 1\58079_4.fw(410) Version 2.5.3.0: ID: 523580 / Support ID: 400205694 safety modules not switching to operational state SDO streaming connection via UDP is not always established when PLC and SafeLogic are booted together. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58076_1.fw(417), 1\58079_3.fw(410), 1\58079_4.fw(410) Version 2.5.2.0: ID: 493915 / Support ID: 400103115, 400101850, 400154063, 400190752 First POWERLINK UDP ASnd SDO transfert after long time takes up to 5s. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58076_1.fw(415), 1\58079_3.fw(410), 1\58079_4.fw(410) Version 2.5.1.0: ID: 462450 / Support ID: 400174514 Execution offunctionblocks rtiPWM und rtiDiv revised. The functions blocks rtiPWM and rtiDiv do not cause a timing error, when they are used as first instruction in the in reACTION task. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 471680 Harmonization of all reACTION modules Harmonization of hardwarefiles forsimilar usage and easier maintenance. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 478575 Module documentation revised Data sheet V1.20 Channeldescription changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58076_1.fw(413), 1\58079_3.fw(410), 1\58079_4.fw(410) Version 2.5.0.1: ID: 477320 Extension for AS 4.2.5 Description file adapted for usage in Automation Studio 4.2.5 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58076_1.fw(413), 1\58079_3.fw(310), 1\58079_4.fw(310) Version 2.5.0.0: ID: 468160 optimization of X2X FW updates Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468165 / Support ID: 400177243 X2X FW update of several X2X modules is not working Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468170 / Support ID: 400178654 Safety modules in connection with PLK BCs, with only input datapoints, are not initialized.by SL Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468565 CiR support Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\58076_1.fw(413), 1\58079_3.fw(310), 1\58079_4.fw(310) Version 1.2.1.0: ID: 463205 hwx adaption Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\58076_1.fw(411), 1\58079_3.fw(310), 1\58079_4.fw(310) Version 1.2.0.0: ID: 460130 / Support ID: 400168329 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel descriptionchanged: No Configuration description changed: No Firmware changed:Yes ID: 460250 / Support ID: 400150525 Error 114834 "Fehler interner SLX-Kommandokanal" bei CPU PowerCycle wenn SLX hinter BC Channel description changed: No Configuration description changed: No Firmwarechanged: Yes Firmware: 1\58076_1.fw(411), 1\58079_3.fw(310), 1\58079_4.fw(310) Version 1.1.0.0: ID: 439125 / Support ID: 400150496 I/O modules behind POWERLINK bus controllers no longer achieving Operationalmode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID:439230 / Support ID: 400128436 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 460130 / Support ID: 400168329 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 460250 / Support ID: 400150525 Error 114834 "Fehler interner SLX-Kommandokanal" bei CPU PowerCycle wenn SLX hinter BC Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58076_1.fw(411), 1\58079_3.fw(310), 1\58079_4.fw(310) Version 1.0.3.0: ID: 432475 hwx-file changes, documentation correction Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\58076_1.fw(300), 1\58079_3.fw(300),1\58079_4.fw(300) Version 1.0.2.0: ID: 395195 Support X67BC81RT.L12 Support for AutomationStudio incl. documentation (English + German) Channel description changed: No Configuration description changed: No Firmware changed: No ID: 424950 Firmware update extended firmware files for hardware variant 4 added Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58076_1.fw(300), 1\58079_3.fw(300), 1\58079_4.fw(300) Version 1.0.1.0: ID: 400650 Status byte added Statusreply for power supply added Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\58076_1.fw(300), 1\58079_2.fw(200), 1\58079_3.fw(200) Version 1.0.0.1: ID: 393325 Support X67BC81RT.L12 Support for AutomationStudio incl. documentation Channel description changed: No Configurationdescription changed: No Firmware changed: No Firmware: 1\58076_1.fw(300), 1\58079_2.fw(200), 1\58079_3.fw(200) Version 1.0.0.0: ID: 357925 Support X67BC81RT.L12 Support for Automation Studio Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58076_1.fw(210), 1\58079_2.fw(105), 1\58079_3.fw(105) |
|||||
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
2.8.0.0 | * | 12.12.2018 | 4 MB | EXE | AS4_HW_X67BC81RT.L12.exe | |
Popis |
V4.1 HW Upgrade (X67BC81RT.L12) Revision information X67BC81RT.L12 Version 2.8.0.0: ID: 619225 / Support ID: 400257683 DNA: PLKhub forwarding for the next node not enabled in rare cases Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 619255 / Support ID: 400262159 Outputs of I/O modules behind the bus coupler not working in some cases if poll-response chaining active Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 621715 / Support ID: 400264883 Display of further diagnostic data points in the I / O mapping of theX2X interface from the X67 bus controller Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\58076_1.fw(426), 1\58079_2.fw(430), 1\58079_3.fw(430), 1\58079_4.fw(430) Version 2.6.0.0: ID: 543990 / Support ID: 400223930 PLK BC not including X2X modules correctly after X2X configuration change Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 570545 / Support ID: 400234859 PLKBC not including X2X modules correctly after X2X configuration change Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 590155 Correction of the functionalityof the timestamp outputs Behavour of the timestamp Bit0 flags of CntTs and LatchTs outputs corrected Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 591985 Module documentation revised Data sheet V 1.37 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58076_1.fw(425), 1\58079_2.fw(430), 1\58079_3.fw(430),1\58079_4.fw(430) Version 2.5.6.0: ID: 548865 Module documentation revised Data sheet V1.36 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 551165 Startup time optimizations Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58076_1.fw(421), 1\58079_3.fw(410), 1\58079_4.fw(410) Version 2.5.4.0: ID: 540340 / Support ID: 400202320 BC sporadically not going into Operational due to X2X-bus problems at startup Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58076_1.fw(419), 1\58079_3.fw(410), 1\58079_4.fw(410) Version 2.5.3.0: ID: 523580 / Support ID: 400205694 safety modules not switching to operational state SDO streaming connectionvia UDP is not always established when PLC and SafeLogic are booted together. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58076_1.fw(417), 1\58079_3.fw(410), 1\58079_4.fw(410) Version 2.5.2.0: ID: 493915 / Support ID: 400103115, 400101850, 400154063, 400190752 First POWERLINK UDP ASnd SDO transfert after long time takes up to 5s. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58076_1.fw(415), 1\58079_3.fw(410), 1\58079_4.fw(410) Version 2.5.1.0: ID: 462450 / Support ID: 400174514 Execution of functionblocks rtiPWM und rtiDiv revised. The functions blocks rtiPWM and rtiDiv do not cause a timing error, when they are used as first instruction in the in reACTION task. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 471680 Harmonization of all reACTION modules Harmonization of hardwarefiles for similar usage and easier maintenance. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 478575 Module documentation revised Data sheet V1.20 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58076_1.fw(413), 1\58079_3.fw(410), 1\58079_4.fw(410) Version 2.5.0.1: ID: 477320 Extension for AS 4.2.5 Description file adapted for usage in Automation Studio 4.2.5 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58076_1.fw(413), 1\58079_3.fw(310), 1\58079_4.fw(310) Version 2.5.0.0: ID: 468160 optimization of X2X FW updates Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468165 / Support ID: 400177243 X2X FW update of several X2X modules is not working Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468170 / Support ID: 400178654 Safety modules in connection with PLK BCs, with only input datapoints, are not initialized.by SL Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468565 CiR support Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\58076_1.fw(413), 1\58079_3.fw(310), 1\58079_4.fw(310) Version 1.2.1.0: ID: 463205 hwx adaption Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\58076_1.fw(411), 1\58079_3.fw(310),1\58079_4.fw(310) Version 1.2.0.0: ID: 460130 / Support ID: 400168329 I/O modules behind POWERLINK bus controllers no longer achievingOperationalmode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 460250 / Support ID: 400150525 Error 114834 "Fehler internerSLX-Kommandokanal" bei CPU PowerCycle wenn SLXhinter BC Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58076_1.fw(411), 1\58079_3.fw(310), 1\58079_4.fw(310) Version 1.1.0.0: ID: 439125 / Support ID: 400150496 I/Omodules behind POWERLINK bus controllers no longer achieving Operationalmodeafter multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 439230 / Support ID: 400128436 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 460130 / Support ID: 400168329 I/O modulesbehind POWERLINK bus controllers no longer achieving Operationalmode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 460250 / Support ID: 400150525 Error 114834 "Fehler interner SLX-Kommandokanal" bei CPU PowerCycle wenn SLX hinter BC Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58076_1.fw(411), 1\58079_3.fw(310), 1\58079_4.fw(310) Version 1.0.3.0: ID: 432475 hwx-file changes, documentation correction Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\58076_1.fw(300), 1\58079_3.fw(300), 1\58079_4.fw(300) Version 1.0.2.0: ID: 395195 Support X67BC81RT.L12 Support for AutomationStudio incl. documentation (English + German) Channel description changed: No Configuration description changed:No Firmware changed: No ID: 424950 Firmware update extended firmware files for hardware variant 4 added Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58076_1.fw(300), 1\58079_3.fw(300), 1\58079_4.fw(300) Version 1.0.1.0: ID: 400650 Status byte added Status reply for power supply added Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\58076_1.fw(300), 1\58079_2.fw(200), 1\58079_3.fw(200) Version 1.0.0.1: ID: 393325 Support X67BC81RT.L12 Support for AutomationStudio incl. documentation Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58076_1.fw(300), 1\58079_2.fw(200), 1\58079_3.fw(200) Version 1.0.0.0: ID: 357925 Support X67BC81RT.L12 Support for Automation Studio Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58076_1.fw(210), 1\58079_2.fw(105), 1\58079_3.fw(105) |
|||||
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
2.6.0.0 | * | 09.05.2018 | 4 MB | EXE | AS4_HW_X67BC81RT.L12.exe | |
Popis |
V4.1 HW Upgrade (X67BC81RT.L12) Revision information X67BC81RT.L12 Version 2.6.0.0: ID: 543990 / Support ID: 400223930 PLK BC not including X2X modules correctly after X2X configuration change Channeldescription changed: No Configuration description changed: No Firmware changed: Yes ID: 570545 / Support ID: 400234859 PLK BC not including X2X modules correctly after X2X configuration change Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 590155 Correction of the functionality of the timestamp outputs Behavour of the timestamp Bit0 flags of CntTs and LatchTs outputs corrected Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 591985 Module documentation revised Data sheet V 1.37 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58076_1.fw(425), 1\58079_2.fw(430), 1\58079_3.fw(430), 1\58079_4.fw(430) Version 2.5.6.0: ID: 548865 Module documentation revised Data sheet V1.36 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 551165 Startup time optimizations Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58076_1.fw(421), 1\58079_3.fw(410), 1\58079_4.fw(410) Version 2.5.4.0: ID: 540340 / Support ID: 400202320 BC sporadically not going into Operational due to X2X-bus problems at startup Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58076_1.fw(419), 1\58079_3.fw(410), 1\58079_4.fw(410) Version 2.5.3.0: ID: 523580 / Support ID: 400205694 safety modules not switching to operational state SDO streaming connection via UDP is not always established when PLC and SafeLogic are booted together. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58076_1.fw(417), 1\58079_3.fw(410), 1\58079_4.fw(410) Version 2.5.2.0: ID: 493915 / Support ID: 400103115, 400101850, 400154063, 400190752 First POWERLINK UDP ASnd SDO transfert after long time takes up to 5s. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware:1\58076_1.fw(415), 1\58079_3.fw(410), 1\58079_4.fw(410) Version 2.5.1.0: ID: 462450 / Support ID: 400174514 Execution of functionblocks rtiPWM und rtiDiv revised. The functions blocks rtiPWM and rtiDiv do not cause a timing error, when they are used as first instruction in the in reACTION task. Channel description changed: No Configuration descriptionchanged: No Firmware changed: Yes ID: 471680 Harmonizationof all reACTION modules Harmonization of hardwarefiles for similar usageand easier maintenance. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 478575 Module documentation revised Data sheet V1.20 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58076_1.fw(413), 1\58079_3.fw(410), 1\58079_4.fw(410) Version 2.5.0.1: ID: 477320 Extension for AS 4.2.5 Description file adapted for usage in Automation Studio 4.2.5 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58076_1.fw(413), 1\58079_3.fw(310), 1\58079_4.fw(310) Version 2.5.0.0: ID: 468160 optimization of X2X FW updates Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468165 / Support ID: 400177243 X2X FW update of several X2X modules is not working Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468170 / Support ID: 400178654 Safety modules in connection with PLK BCs, with only input datapoints, are not initialized.by SL Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468565 CiR support Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\58076_1.fw(413), 1\58079_3.fw(310), 1\58079_4.fw(310) Version 1.2.1.0: ID: 463205 hwx adaption Channeldescription changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\58076_1.fw(411), 1\58079_3.fw(310), 1\58079_4.fw(310) Version 1.2.0.0: ID: 460130 / Support ID: 400168329 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 460250 / Support ID: 400150525 Error 114834 "Fehler interner SLX-Kommandokanal" bei CPU PowerCycle wenn SLX hinter BC Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58076_1.fw(411), 1\58079_3.fw(310), 1\58079_4.fw(310) Version 1.1.0.0: ID: 439125 / Support ID: 400150496 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configurationdescription changed: No Firmware changed: Yes ID: 439230 / Support ID: 400128436 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 460130 / Support ID: 400168329 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 460250 / Support ID: 400150525 Error 114834 "Fehler interner SLX-Kommandokanal" bei CPU PowerCycle wenn SLX hinter BC Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58076_1.fw(411), 1\58079_3.fw(310), 1\58079_4.fw(310) Version 1.0.3.0: ID: 432475 hwx-file changes, documentation correction Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\58076_1.fw(300), 1\58079_3.fw(300), 1\58079_4.fw(300) Version 1.0.2.0: ID: 395195 Support X67BC81RT.L12 Support for AutomationStudio incl. documentation (English + German) Channel description changed: No Configuration description changed: No Firmware changed: No ID: 424950 Firmware update extended firmware files for hardware variant 4 added Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58076_1.fw(300), 1\58079_3.fw(300), 1\58079_4.fw(300) Version1.0.1.0: ID: 400650 Status byte added Status reply for power supply added Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\58076_1.fw(300), 1\58079_2.fw(200), 1\58079_3.fw(200) Version 1.0.0.1: ID: 393325 Support X67BC81RT.L12 Support for AutomationStudio incl. documentation Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58076_1.fw(300), 1\58079_2.fw(200), 1\58079_3.fw(200) Version 1.0.0.0: ID: 357925 Support X67BC81RT.L12 Support for Automation Studio Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58076_1.fw(210), 1\58079_2.fw(105), 1\58079_3.fw(105) |
|||||
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
2.5.6.0 | * | 27.09.2017 | 4 MB | EXE | AS4_HW_X67BC81RT.L12.exe | |
Popis |
V4.1 HW Upgrade (X67BC81RT.L12) Revision information X67BC81RT.L12 Version 2.5.6.0: ID: 548865 Module documentation revised Data sheet V1.36 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 551165 Startup time optimizations Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58076_1.fw(421), 1\58079_3.fw(410), 1\58079_4.fw(410) Version 2.5.4.0: ID: 540340 / Support ID: 400202320 BC sporadically not going into Operational due to X2X-bus problems at startup Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58076_1.fw(419), 1\58079_3.fw(410), 1\58079_4.fw(410) Version 2.5.3.0: ID: 523580 / Support ID: 400205694 safety modules not switching to operational state SDO streaming connection via UDP is not alwaysestablished when PLC and SafeLogic are booted together. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58076_1.fw(417), 1\58079_3.fw(410), 1\58079_4.fw(410) Version 2.5.2.0: ID: 493915 / Support ID: 400103115, 400101850, 400154063, 400190752 First POWERLINK UDP ASnd SDO transfert after longtime takes up to 5s. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58076_1.fw(415), 1\58079_3.fw(410), 1\58079_4.fw(410) Version 2.5.1.0: ID: 462450 / Support ID: 400174514 Execution of functionblocks rtiPWM und rtiDiv revised. The functions blocks rtiPWM and rtiDiv do not cause a timing error, when they are used as first instruction in the in reACTION task. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 471680 Harmonization of all reACTION modules Harmonization of hardwarefiles for similar usage and easier maintenance. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 478575 Module documentation revised Data sheet V1.20 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58076_1.fw(413), 1\58079_3.fw(410), 1\58079_4.fw(410) Version 2.5.0.1: ID: 477320 Extension for AS 4.2.5 Description file adapted for usage in Automation Studio 4.2.5 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58076_1.fw(413), 1\58079_3.fw(310), 1\58079_4.fw(310) Version2.5.0.0: ID: 468160 optimization of X2X FW updates Channeldescription changed: No Configuration description changed: No Firmware changed: Yes ID: 468165 / Support ID: 400177243 X2X FW update of several X2X modules is not working Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468170 / Support ID: 400178654 Safety modules in connection with PLK BCs, with only input datapoints, are not initialized.by SL Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468565 CiR support Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\58076_1.fw(413), 1\58079_3.fw(310), 1\58079_4.fw(310) Version 1.2.1.0: ID: 463205 hwx adaption Channel description changed: Yes Configuration description changed: No Firmware changed:No Firmware: 1\58076_1.fw(411), 1\58079_3.fw(310), 1\58079_4.fw(310) Version 1.2.0.0: ID: 460130 / Support ID: 400168329 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 460250 / Support ID: 400150525 Error 114834 "Fehler interner SLX-Kommandokanal" bei CPU PowerCycle wenn SLX hinter BC Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58076_1.fw(411), 1\58079_3.fw(310), 1\58079_4.fw(310) Version 1.1.0.0: ID: 439125 / Support ID: 400150496 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 439230 / Support ID: 400128436 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed:No Configuration description changed: No Firmware changed: Yes ID: 460130 / Support ID: 400168329 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed:No Firmware changed: Yes ID: 460250 / Support ID: 400150525 Error 114834 "Fehler interner SLX-Kommandokanal" bei CPU PowerCycle wenn SLXhinter BC Channel description changed: No Configuration descriptionchanged: No Firmware changed: Yes Firmware: 1\58076_1.fw(411), 1\58079_3.fw(310), 1\58079_4.fw(310) Version 1.0.3.0: ID: 432475 hwx-file changes, documentation correction Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\58076_1.fw(300), 1\58079_3.fw(300), 1\58079_4.fw(300) Version 1.0.2.0: ID: 395195 Support X67BC81RT.L12 Support for AutomationStudio incl. documentation (English + German) Channel description changed: No Configuration description changed: No Firmware changed: No ID: 424950 Firmware update extended firmware files for hardware variant 4 added Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58076_1.fw(300), 1\58079_3.fw(300), 1\58079_4.fw(300) Version 1.0.1.0: ID: 400650 Status byte added Status reply for power supply added Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\58076_1.fw(300), 1\58079_2.fw(200), 1\58079_3.fw(200) Version 1.0.0.1: ID: 393325 Support X67BC81RT.L12 Support for AutomationStudio incl. documentation Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58076_1.fw(300), 1\58079_2.fw(200), 1\58079_3.fw(200) Version 1.0.0.0: ID: 357925 Support X67BC81RT.L12 Support for Automation Studio Channel description changed:No Configuration description changed: No Firmware changed: No Firmware: 1\58076_1.fw(210), 1\58079_2.fw(105), 1\58079_3.fw(105) |