DWL@DWL10000340795
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
---|---|---|---|---|---|---|
2.1.0.0 | * | 26.07.2021 | 209 KB | EXE | AS4_HW_5DLSD3.1003-00.exe | |
Popis |
V4.0 HW Upgrade (5DLSD3.1003-00) Revision information 5DLSD3.1003-00.1003-00 Version 2.1.0.0: ID: Adaptations for Automation Studio 4.11 Channel description changed: no Configuration descriptionchanged: yes Firmware changed: no Version 2.0.0.0: ID: 674085 Extensions Hypervisor from AR A4.81 USB allocation between GPOS and RTOS also possible on the Automation Panel.This requires that the appropriate hardware upgrades are used for all components (APC/PPC, AP, SDLx Receiver, SDLx Transmitter). Starting with AS 4.8 following HWX upgrades (or newer) are recommended, mixedoperation of the current and older HWX upgrades is not recommended: APC910 system unit: V2.1.0.0 5PC900.TS17-xx: V2.1.0.0 5AC901.LSD3-00: V2.0.0.0 APC2100 system unit: V2.1.0.0 5ACCLI01.SDL3-000: V2.0.0.0 AP9xD panels: V2.0.0.0 Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 674090 EPLAN Daten implemented Channel description changed: No Configuration description changed: Yes Firmware changed: No Version 1.1.0.0: ID: 499855 The resistive touch doesn't work with an APC2100 The resistive touch works now, if the SDL3 receiver is used together with an APC2100 Channel description changed: No Configuration description changed: No Firmware changed: No Version 1.0.0.0: ID: 400370 Initial version V1.0.0.0 Toconfigure a SDL3 Panel following hardware upgrades have to be installed, too: APC910 system unit 5PC910.SX0x-00 >= V1.3.0.0 SDL3 Transmitter: 5AC901.LSD3-00 >= V1.0.0.0 Automation Panel 9x3: 5AP9xD.xxxx-xx >= V1.0.1.0 Further following versions of components are mandatory: Support from Automation Studio version 4.0.23.x and 4.1.5.x Support from Visual Components 4.15.1. Channel description changed: Yes Configuration description changed: Yes Firmware changed: No |
|||||
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
2.0.0.0 | * | 08.04.2020 | 206 KB | EXE | AS4_HW_5DLSD3.1003-00.exe | |
Popis |
V4.0 HW Upgrade (5DLSD3.1003-00) Revision information 5DLSD3.1003-00 Version 2.0.0.0: ID: 674085 Extensions Hypervisor from AR A4.81 USB allocation between GPOS and RTOS also possible on the Automation Panel.This requires that the appropriate hardware upgrades are used for allcomponents (APC/PPC, AP, SDLx Receiver, SDLx Transmitter). Starting with AS 4.8 following HWX upgrades (or newer) are recommended, mixedoperation of the current and older HWX upgrades is not recommended: APC910 system unit: V2.1.0.0 5PC900.TS17-xx: V2.1.0.0 5AC901.LSD3-00: V2.0.0.0 APC2100 system unit: V2.1.0.0 5ACCLI01.SDL3-000: V2.0.0.0 AP9xD panels: V2.0.0.0 Channel description changed: No Configurationdescription changed: Yes Firmware changed: No ID: 674090 EPLAN Daten implemented Channel description changed: No Configurationdescription changed: Yes Firmware changed: No Version 1.1.0.0: ID: 499855 The resistive touch doesn't work with an APC2100 The resistive touch works now, if the SDL3 receiver is used together with an APC2100 Channel description changed: No Configuration description changed: No Firmware changed: No Version 1.0.0.0: ID: 400370 Initial version V1.0.0.0 To configure a SDL3 Panel following hardware upgrades have to be installed,too: APC910 system unit 5PC910.SX0x-00 >= V1.3.0.0 SDL3 Transmitter: 5AC901.LSD3-00 >=V1.0.0.0 Automation Panel 9x3: 5AP9xD.xxxx-xx >= V1.0.1.0 Further following versions of components are mandatory: Support from Automation Studio version 4.0.23.x and 4.1.5.x Support from Visual Components 4.15.1. Channel description changed: Yes Configuration description changed: Yes Firmware changed: No |
|||||
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
1.1.0.0 | * | 29.11.2016 | 275 KB | EXE | AS4_HW_5DLSD3.1003-00.exe | |
Popis |
V4.0 HW Upgrade (5DLSD3.1003-00) Revision information 5DLSD3.1003-00 Version 1.1.0.0: ID: 499855 The resistive touch doesn't work with an APC2100 The resistive touch works now, if the SDL3 receiver isused together with anAPC2100 Channel description changed: No Configuration description changed: No Firmware changed: No Version 1.0.0.0: ID: 400370 Initial version V1.0.0.0 To configure a SDL3 Panel following hardware upgrades have to be installed,too: APC910 system unit 5PC910.SX0x-00 >= V1.3.0.0 SDL3 Transmitter: 5AC901.LSD3-00 >= V1.0.0.0 Automation Panel 9x3: 5AP9xD.xxxx-xx >= V1.0.1.0 Further following versions of components are mandatory: Support from Automation Studio version 4.0.23.x and 4.1.5.x Supportfrom Visual Components 4.15.1. Channel description changed: Yes Configuration description changed: Yes Firmware changed: No |