DWL@DWL10000327782
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
---|---|---|---|---|---|---|
1.5.0.0 | * | 26.04.2021 | 3 MB | EXE | AS3.0_HW_X67MM2436.exe | |
Popis |
V3.0 HW Upgrade (X67MM2436) Revision information X67MM2436 Version 1.5.0.0: ID: 721190 support for HW-variant 4 Channel description changed: No Configuration description changed: No Firmwarechanged: Yes ID: 721210 Improved protection against overload Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes ID: 725045 Module documentation revised Data sheet V2.40 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\8819_1.fw(110), 1\8819_2.fw(110), 1\8819_3.fw(110), 1\8819_4.fw(110) Version 1.4.0.0: ID: Adaptations for Automation Studio 4.8 Channeldescription changed: no Configuration description changed: yes Firmware changed: no Version 1.3.1.0: ID: 600100 Module documentation revised Data sheet V2.34 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\8819_1.fw(100), 1\8819_2.fw(100), 1\8819_3.fw(100) Version 1.3.0.0: ID: 463215 support HW Variante 3 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\8819_1.fw(100), 1\8819_2.fw(100), 1\8819_3.fw(100) Version 1.2.0.0: ID: 374900 / Support ID: 400130265 X67MM2436 - same encoder functionality like X20MM2436 Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\8819_1.fw(8), 1\8819_2.fw(8) Version 1.1.0.2: ID: 320995 Removed wrong filter value in channel description Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\8819_1.fw(6), 1\8819_2.fw(6) Version 1.1.0.0: ID: 188250 / Support ID: 400009741 Support at CANIO bus controller with SG3 target Channel description changed: Yes Configurationdescription changed: No Firmware changed: No ID: 307635 Module bootup timeout configured Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\8819_1.fw(6), 1\8819_2.fw(6) Version 1.0.1.0: ID: 263755 / Support ID: 400069673 X67MM2436 on CANIO Controller leads to malfunction of subsequent modules ->Repair by means of correction of erroneous HWC-entry Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\8819_1.fw(6), 1\8819_2.fw(6) Version 1.0.0.1: ID: 177375 HWC file has to be better documented 4-Quadrant-Mode was implemented Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\8819_1.fw(6), 1\8819_2.fw(6) |
|||||
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
1.3.1.0 | * | 25.04.2019 | 3 MB | EXE | AS3.0_HW_X67MM2436.exe | |
Popis |
V3.0 HW Upgrade (X67MM2436) Revision information X67MM2436 Version 1.3.1.0: ID: 600100 Module documentation revised Data sheet V2.34 Channel description changed: No Configuration descriptionchanged: No Firmware changed: No Firmware: 1\8819_1.fw(100), 1\8819_2.fw(100), 1\8819_3.fw(100) Version 1.3.0.0: ID: 463215 support HW Variante 3 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\8819_1.fw(100), 1\8819_2.fw(100), 1\8819_3.fw(100) Version 1.2.0.0: ID: 374900 / Support ID: 400130265 X67MM2436 - same encoder functionality like X20MM2436 Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\8819_1.fw(8), 1\8819_2.fw(8) Version 1.1.0.2: ID: 320995 Removed wrong filter value in channel description Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\8819_1.fw(6), 1\8819_2.fw(6) Version 1.1.0.0: ID: 188250 / Support ID: 400009741 Support at CANIO bus controller with SG3 target Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 307635 Module bootup timeout configured Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\8819_1.fw(6), 1\8819_2.fw(6) Version 1.0.1.0: ID: 263755 / Support ID: 400069673 X67MM2436 on CANIO Controller leads to malfunction of subsequent modules ->Repair by means of correction of erroneous HWC-entry Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\8819_1.fw(6), 1\8819_2.fw(6) Version 1.0.0.1: ID: 177375 HWC file has to be better documented 4-Quadrant-Mode was implemented Channel description changed: Yes Configuration descriptionchanged: No Firmware changed: No Firmware: 1\8819_1.fw(6), 1\8819_2.fw(6) |
|||||
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
1.3.0.0 | * | 03.02.2016 | 2 MB | EXE | AS3.0_HW_X67MM2436.exe | |
Popis |
V3.0 HW Upgrade (X67MM2436) Revision information X67MM2436 Version 1.3.0.0: ID: 463215 support HW Variante 3 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\8819_1.fw(100), 1\8819_2.fw(100), 1\8819_3.fw(100) Version 1.2.0.0: ID: 374900 / Support ID: 400130265 X67MM2436 - same encoder functionality like X20MM2436 Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\8819_1.fw(8), 1\8819_2.fw(8) Version 1.1.0.2: ID: 320995 Removed wrong filter value in channel description Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\8819_1.fw(6), 1\8819_2.fw(6) Version 1.1.0.0: ID: 188250 / Support ID: 400009741 Support at CANIObus controller with SG3 target Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 307635 Module bootup timeout configured Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\8819_1.fw(6), 1\8819_2.fw(6) Version 1.0.1.0: ID: 263755 / Support ID: 400069673 X67MM2436 on CANIO Controller leads to malfunction of subsequent modules ->Repair by means of correction of erroneous HWC-entry Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\8819_1.fw(6), 1\8819_2.fw(6) Version 1.0.0.1: ID: 177375 HWC file has to be better documented 4-Quadrant-Mode was implemented Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\8819_1.fw(6), 1\8819_2.fw(6) |