2.5.4.0 | * | 05.07.2017 | 2 MB | EXE | AS2.6_HW_X20BC0083.exe | |
Popis |
V2.6 HW Upgrade (X20BC0083) Revision information X20BC0083 Version 2.5.4.0: ID: 539100 / Support ID: 400202320 BC sporadically not going into Operational due to X2X-bus problems at startup Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7966_1.fw(419), 1\7966_3.fw(419), 1\7966_4.fw(419) Version 2.5.3.0: ID: 517445 / Support ID: 400205694 SDO streaming connection via UDP is not always established when PLC and BC are booted together. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7966_1.fw(417), 1\7966_3.fw(417), 1\7966_4.fw(417) Version 2.5.2.0: ID: 271540/ Support ID: 400103115, 400101850, 400154063, 400190752 First POWERLINKUDP ASnd SDO transfert after long time takes up to 5s. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7966_1.fw(415), 1\7966_3.fw(415), 1\7966_4.fw(415) Version 2.5.0.0: ID: 431950 optimization of X2X FW updates Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 465250 / Support ID: 400177243 X2X FW update of several X2X modules is not working Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 467335 / Support ID: 400178654 Safety modules in connection with PLK BCs, with only input datapoints, are not initialized.by SL Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468515 CiR support Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\7966_1.fw(413), 1\7966_3.fw(413), 1\7966_4.fw(413) Version 2.3.0.0: ID: 428150 / Support ID: 400150525 Error 114834 "Fehler interner SLX-Kommandokanal" bei CPU PowerCycle wenn SLX hinter BC Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 437925 / Support ID: 400157710 AS4.2.5 modifications Channel description changed: Yes Configuration description changed: Yes Firmware changed: No ID: 455930 / Support ID: 400168329 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7966_1.fw(411), 1\7966_3.fw(411), 1\7966_4.fw(411) Version 2.2.0.0: ID: 338175 Expansion for AR to detect the Ethernet port being used Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 380760 / Support ID: 400128436 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 431210 / Support ID: 400150496 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7966_1.fw(400), 1\7966_3.fw(400), 1\7966_4.fw(400) Version 2.1.0.0: ID: 393570 / Support ID: 400138475 Upgrade 2.0.0.0 leads to a problem with WinIO switchboard Channel description changed: Yes Configuration description changed: Yes Firmware changed: No ID: 396220 X2XLink-BC: StationAtBusEnd does not change, when empty backplanes are added or removed. When empty backplanes are plugged or unplugged on the end of the X2XLink the diagnostic data point "StationAtBusEnd" die not change. The data point die change when IO Modules were removed or added. A new handshake between Automation Runtime and firmware was implemented to update the "StationAtBusEnd" faster. The same problem also occurs with modules where the X2XLink is supplied with power, but the supply for the IO is missing. Channel descriptionchanged: Yes Configuration description changed: No Firmware changed: Yes Firmware: 1\7966_1.fw(300), 1\7966_3.fw(300), 1\7966_4.fw(300) Version 2.0.0.0: ID: 385125 / Support ID: 400129274 Uncommon X2X settings cause permanent boot of bus controller Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7966_1.fw(210), 1\7966_3.fw(210), 1\7966_4.fw(210) Version 1.3.5.0: ID: 328265 / Support ID: 400106479 Firmware of special I/O modules on POWERLINK bus controllers not updating reliably when using an X2X cycle time less than 400 µs This problem occurs if the following conditions are met at the same time: - Firmware being updated on I/O modules on a POWERLINK bus controller - Some I/O modules using an older revision Current I/O module revisions are not affected. There is thereforeno problem if a customer is replacing an old I/O module with a new I/O moduleon an existing system. - X2X cycle time < 400 us - Short X2X cable length configured This problem does not occur if longer cable lengthsare configured (e.g. the default value of 1000 m). Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7966_1.fw(170), 1\7966_3.fw(170), 1\7966_4.fw(170) Version 1.3.4.0: ID: 299875 / Support ID: 400051206 Expansion: Link- selector flag New datapoints:<br/>- RedundancyFirstLinkState<br/>- RedundancySecondLinkState Channel description changed: Yes Configuration description changed: Yes Firmware changed: No ID: 310065 / Support ID: 400097674 POWERLINK V1: Bug-fix for Up/Downgrade POWERLINK V1 FW upgrade problem could be accored after PowerOn beginning with HW- Upgrade Version 1.3.1.0 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7966_1.fw(168), 1\7966_3.fw(168), 1\7966_4.fw(168) Version 1.3.3.0: ID: 302500 / Support ID: 400094368 ACOPOSmulti with SafeMC, asynchronous communication lost When there was a high load on the CPU, asynchronous communication to the buscontroller was interrupted. Restarting the boscontroller restored communication. Loss of asynchronous communication caused the safety-IO to stop. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7966_1.fw(167), 1\7966_3.fw(167), 1\7966_4.fw(167) Version 1.3.2.0: ID: 295655 / Support ID: 400090781 Problem with FW-Update of IO modules on Powerlink buscontrollers The firmware update of IO modules does not work in certain configurations. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7966_1.fw(165), 1\7966_3.fw(165), 1\7966_4.fw(165) Version 1.3.1.0: ID: 288750 Certain X2X configurations don't work In very rare I/O constellations, the X2X modules don't start Channel description changed: No Configuration description changed: No Firmware changed: Yes ID:290070 New Hardwarevariant 4 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware:1\7966_1.fw(163), 1\7966_3.fw(163), 1\7966_4.fw(163) Version 1.3.0.0: ID: 240940 New X2X datapoints - NettimeOffsetX2X and NettimeX2X Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes ID: 274795 Support of 'Multiple Asynchronous Send' Channel description changed: No Configurationdescription changed: No Firmware changed: Yes Firmware: 1\7966_1.fw(160), 1\7966_3.fw(160) Version 1.2.1.0: ID: 247260 DNA runup upgraded Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7966_1.fw(152), 1\7966_3.fw(152) Version 1.2.0.0: ID: 245095 DNA support; Update behavior on X2X bus of the BC improved - DNA support (Dynamic NodeAllocation) - faster updating of modules with big FW files on the X2X bus of the BC - new objects: 20A3h and 2000h/9 Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\7966_1.fw(150), 1\7966_3.fw(150) Version 1.0.8.0: ID: 218490 Extensions and Bugfixes - Firmware-Version is transferred via IdentResponse in the first 4 bytes ofthe field VendorSpecificExt1 - Support of PollResponse-Chaining Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7966_1.fw(145) Version 1.0.7.0: ID: 214340 Extensions and Bugfixes - In systems with high X2X load it happened that IO modules were not restarted when the CPU did a warmstart (A&P 211805) - Activation of MultipleRead/Write feature for faster startup after configuration change - Writing to Objekt 20F0h/SubIndex 22 caused SDO errors when accessed faster than allowed - Number of configuration entries per IO module changed from 100 to 155 Channel description changed: No Configurationdescription changed: No Firmware changed: Yes Firmware: 1\7966_1.fw(144) Version 1.0.6.0: ID: 210955 Extensions and Bugfixes - Error correction for operation in Powerlink V1 networks (A&P 210765) Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7966_1.fw(143) Version 1.0.5.0: ID: 210215 Extensions and Bugfixes - New ASICS will be set to 3mA output current (A&P 182905) - Optimization of SDO communication (unnecessary acknowledges removed) - Support of commands ReadMultipleParameter / WriteMultipleParameter - NodeID assignment by digital inputs supported (NodeId 241 and 242) - Minor corrections certification - ASnd frames with unknown ServiceID could disturb the BC (only possible with 3rdparty MN) - Access to not existing objects in OD could cause firmware crash - When running X2X cycle times <200 us the X2X Bus was not working correctly (A&P 190630) - When in state PREOP_2 no SoC is received for 10secthe BC will fall back in PREOP_1 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7966_1.fw(142) Version 1.0.4.1: ID: 183285 New info-/diagnostic data points, new FW 1.39 for signal filter and corrections New info-/diagnostic data points in HWC, new FW 1.39 for signal filter and corrections Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7966_1.fw(141) Version1.0.3.0: ID: 173310 Extensions and Bugfixes - Improvement of X2X Timings (Jitter reduced from 180ns to 20ns) (A&P167857 und 171987) - Optimizations for operation in 200us networks - 2 nodes with the samenode number generated disturbance on the network (A&P 166040) - Functions for a new firmware download mechanism implemented (A&P 168537) Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7966_1.fw(138) Version 1.0.2.0: ID: 164640 Extensions - Extensions for operation with Safety Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7966_1.fw(136) |